文献速递青光眼

房水中基质细胞蛋白水平与小梁切除术手术结局的关系

Matricellular Protein Levels in Aqueous Humor and Surgical Outcomes of Trabeculectomy.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2018-01-01

本研究量化了既往急性原发性房角关闭(APAC)眼房水中三种基质细胞蛋白水平,并分析其与小梁切除术后滤过泡形态及手术结局的相关性。结果显示,手术失败组房水SPARC水平显著更高,低SPARC组总体成功率更高,且SPARC水平与滤过泡评分正相关。

要点

  • 既往APAC眼小梁切除术后失败组房水SPARC水平显著高于成功组(P=0.009)。
  • 低SPARC组完全成功(P=0.005)和条件成功(P=0.018)均显著高于高SPARC组。
  • SPARC水平与滤过泡评分正相关(P<0.001,R2=0.471)。

核心结论

  • 在既往APAC患者中,房水SPARC水平是小梁切除术手术结果的预后因素。
  • 调节SPARC表达可能在滤过手术后具有潜在临床应用价值。

研究设计与样本

  • 前瞻性研究,采集40只既往APAC眼的房水样本。
  • 使用多重免疫分析试剂盒测量SPARC、凝血酶敏感蛋白-2和骨桥蛋白浓度。
  • 使用Goldmann压平眼压计测量眼压,前节OCT评估滤过泡形态并计算滤过泡评分。

主要发现

  • 小梁切除术后18个月,手术失败组房水SPARC蛋白显著高于成功组(P=0.009)。
  • 低SPARC水平眼完全成功率显著高于高SPARC水平眼(P=0.005),条件成功率亦显著更高(P=0.018)。
  • 多因素logistic回归显示,较高SPARC水平眼滤过手术失败可能性更大:完全成功P=0.006,OR=6.458;条件成功P=0.033,OR=2.608。
  • SPARC水平与滤过泡评分呈正相关(P<0.001,R2=0.471)。

关键数值与推荐

  • 手术失败组与成功组比较,SPARC差异P=0.009。
  • 低SPARC组与高SPARC组比较,完全成功P=0.005,条件成功P=0.018。
  • 多因素logistic回归:完全成功P=0.006,OR=6.458;条件成功P=0.033,OR=2.608。
  • SPARC与滤过泡评分相关:P<0.001,R2=0.471。

临床怎么用

  • 对于既往APAC行小梁切除术的患者,可考虑检测房水SPARC水平以辅助预后判断。
  • 高SPARC水平提示滤过手术失败风险较高,可能需要更密切随访。
  • SPARC表达调控可能成为滤过术后改善手术结局的潜在干预靶点。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to quantify levels of three matricellular proteins in the aqueous humor in patients with previous acute primary angle closure (APAC) and investigate their correlation with bleb morphology and surgical outcomes of trabeculectomy. METHODS: In this prospective study, aqueous humor samples were collected from 40 previous APAC eyes. Concentrations of three matricellular proteins-secreted protein acidic and rich in cysteine (SPARC), thrombospondin-2, and osteopontin-were measured using multiplexed immunoassays kits. Intraocular pressure was measured using Goldmann application tonometry. Bleb morphology was assessed using anterior segment optical coherence tomography, and bleb score was calculated according to bleb size and reflectivity. RESULTS: When previous APAC eyes were divided according to surgical outcome 18 months after trabeculectomy, SPARC protein was significantly higher in aqueous humor in the failure group (P = 0.009). When previous APAC eyes were divided according to SPARC level, eyes with low SPARC levels had significantly higher overall success rate compared with eyes with high SPARC levels (P = 0.005 for complete success and P = 0.018 for qualified success). Multiple logistic regression analyses showed that eyes with higher levels of SPARC were more likely to have a failed filtration surgery than were eyes with lower levels of SPARC. For complete success, P = 0.006 and odds ratio (OR) = 6.458; for qualified success, P = 0.033 and OR = 2.608. The level of SPARC was found to have a positive correlation with bleb score (P < 0.001, R2 = 0.471). CONCLUSIONS: In previous APAC patients, the SPARC level in aqueous humor is a prognostic factor for surgical results of trabeculectomy. Modulation of SPARC expression may have potential clinical applications after filtration surgery.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Zhang Z, Miao Y, Wang J, et al. Matricellular Protein Levels in Aqueous Humor and Surgical Outcomes of Trabeculectomy. Invest Ophthalmol Vis Sci. 2018. PMID: 30073351. doi:10.1167/iovs.18-24534

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。