文献速递白内障与屈光手术角膜与眼表疾病青光眼

白内障术后角膜生物力学与眼压变化

Changes in Corneal Biomechanics and Intraocular Pressure Following Cataract Surgery.
PubMed 文献 · Am J Ophthalmol · 2018-07-30

前瞻性干预病例系列纳入39例白内障患者39眼,用Corvis ST于术前及术后1周、1月、3月测量角膜生物力学与眼压。结果显示所有眼压测量值随时间下降,术后3月角膜硬度参数SP A1降低而DA max与整合半径增加,提示角膜变软。

要点

  • 白内障术后所有眼压测量值随时间下降(P < .01)。
  • 术后3月SP A1降低、DA max与整合半径增加,提示角膜变软。
  • CCT术后1周与3月增加,ARTh术后1周与1月降低、3月恢复术前水平。

核心结论

  • 白内障术后眼压与角膜生物力学特性均发生改变,术后3月仍可见角膜硬度降低的表现。

研究设计与样本

  • 前瞻性干预病例系列研究,纳入39例白内障患者39眼,于术前及术后1周、1月、3月行Corvis ST测量。

主要发现

  • 所有眼压测量值随时间下降(P < .01)。
  • CCT在术后1周与3月增加(P < .01)。
  • ARTh在术后1周与1月降低(P < .01),3月恢复至术前水平。
  • DA max与整合半径在术后3月增加(P < .01),SP A1在术后3月降低(P < .01)。
  • CBI在术后1周增加(P < .01),1月恢复至术前水平。

关键数值与推荐

  • CST记录参数包括DA max、DA ratio max 1 mm与2 mm、整合半径、SP A1、ARTh、CBI、CCT、IOPnct与bIOP。
  • 眼压同时用Goldmann压平眼压计与非接触眼压计CT-90A测量。
  • 各时间点比较采用线性混合模型,并分别在有、无对bIOP与CCT校正的条件下进行。

临床怎么用

  • 白内障术后解读Corvis ST生物力学参数与眼压时,需考虑术后时间点及CCT变化的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate the effects of cataract surgery on corneal biomechanics and intraocular pressure (IOP) measured with the updated Corvis ST tonometer (CST). DESIGN: Prospective, interventional case series study. METHODS: This study included 39 eyes of 39 cataract patients. CST measurements were performed at presurgery (Pre) as well as 1 week (1W), 1 month (1M), and 3 months (3M) postsurgery. The following CST parameters were recorded: deformation amplitude max (DA max), DA ratio max 1 mm and 2 mm, integrated radius, stiffness parameter at applanation 1 (SP A1), Ambrosio relational thickness to the horizontal profile (ARTh), Corvis biomechanical index (CBI), central corneal thickness (CCT), noncorrected intraocular pressure (IOPnct), and biomechanically corrected IOP (bIOP). IOP was also measured with Goldmann applanation tonometry and the noncontact tonometer CT-90A. All measurements were compared at each period using the linear mixed model, with and without adjustment for bIOP and CCT. RESULTS: All IOP measurements decreased over time (P < .01). CCT was increased at 1W and 3M (P < .01), whereas ARTh was decreased at 1W and 1M (P < .01), but returned to its Pre level at 3M. DA max and Integrated radius were increased at 3M (P < .01), whereas SP A1 was decreased at 3M (P < .01). CBI was increased at 1W (P < .01), but returned to its Pre level at 1M. CONCLUSIONS: IOP and Corneal biomechanical properties are changed after cataract surgery. In particular, SP A1 decreases while DA max and integrated radius increase, even at 3M, suggesting a less stiff cornea.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Hirasawa K, Nakakura S, Nakao Y, et al. Changes in Corneal Biomechanics and Intraocular Pressure Following Cataract Surgery. Am J Ophthalmol. 2018. PMID: 30071213. doi:10.1016/j.ajo.2018.07.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。