文献速递眼底病与葡萄膜炎

回视成像在羟氯喹视网膜病变评估中的应用

Evaluation of Retromode Imaging for Use in Hydroxychloroquine Retinopathy.
PubMed 文献 · Am J Ophthalmol · 2018-08-15

本研究评估红外激光回视成像在羟氯喹(HCQ)视网膜病变中的应用,并与OCT和FAF比较。62眼HCQ视网膜病变患者均显示旁中心凹或中心周围环形或圆形反射减低区伴脉络膜深血管显影,敏感性100%,特异性在HCQ对照组和两对照组分别为73.0%和76.4%。回视成像检测光感受器缺陷比FAF更敏感,但FAF提供RPE状态信息,回视成像有高敏感性但特异性有限,可作为筛查补充。

要点

  • HCQ视网膜病变在回视成像上表现为旁中心凹或中心周围环形/圆形反射减低伴脉络膜深血管显影。
  • 回视成像检测视网膜病变敏感性100%,特异性在HCQ对照组73.0%、两对照组76.4%。
  • 回视成像检测光感受器缺陷比FAF更敏感,尤其早期病变,但FAF可提供RPE状态信息。

核心结论

  • 回视成像可能有助于检测HCQ视网膜病变,其高敏感性但特异性有限,提示在筛查中作为补充角色,尤其用于早期检测。

研究设计与样本

  • 诊断效度评估研究,纳入62眼(31例)HCQ视网膜病变患者、270眼(135例)HCQ无视网膜病变对照和162眼(81例)正常对照。
  • HCQ视网膜病变诊断采用美国眼科学会推荐的筛查试验,包括OCT、FAF和视野检查。
  • 回视成像使用共焦扫描激光检眼镜对患者组和两个对照组进行,并与OCT B扫描外层视网膜改变及FAF表现比较。

主要发现

  • 所有HCQ视网膜病变患者均显示旁中心凹或中心周围环形或圆形反射减低区伴脉络膜深血管显影,敏感性100%。
  • 回视成像特异性在HCQ对照组为73.0%,在两对照组为76.4%。
  • 与FAF相比,回视成像检测光感受器缺陷更敏感,尤其早期视网膜病变眼。
  • FAF提供视网膜色素上皮状态额外信息,回视成像无法区分光感受器缺陷与RPE改变。

关键数值与推荐

  • HCQ视网膜病变诊断依据美国眼科学会推荐的筛查试验,包括OCT、FAF和视野检查。
  • 回视成像敏感性100%,特异性在HCQ对照组73.0%、两对照组76.4%。

临床怎么用

  • 回视成像可作为HCQ视网膜病变筛查的补充手段,尤其用于早期检测,但需结合OCT和FAF综合评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To report on the application of retromode imaging using infrared lasers to eyes with hydroxychloroquine (HCQ) retinopathy, and to compare retromode images with those acquired via conventional objective screening imaging modalities-optical coherence tomography (OCT) and fundus autofluorescence (FAF). DESIGN: Diagnostic validity assessment. METHODS: Setting: Institutional. PATIENT POPULATION: Sixty-two eyes of 31 patients with systemic lupus erythematosus or rheumatoid arthritis who were treated with HCQ and developed HCQ retinopathy (patient group), 270 eyes of 135 patients with the same diseases who were treated with HCQ but exhibit no retinopathy (HCQ-taking control group), and 162 eyes of 81 normal controls (normal control group). OBSERVATION PROCEDURES: Diagnosis of HCQ retinopathy was performed with screening tests recommended by the American Academy of Ophthalmology, including OCT, FAF, and visual field examination. Retromode imaging, using confocal scanning laser ophthalmoscopy, was performed for the patient group and both control groups. The findings on retromode imaging were correlated with outer retinal changes on OCT B-scan images, then compared with the FAF findings. The sensitivity and specificity of retromode imaging were calculated. MAIN OUTCOME MEASURES: Findings of retromode imaging and sensitivity/specificity of the imaging. RESULTS: All patients with HCQ retinopathy showed a parafoveal or pericentral ring-shaped or round area of decreased reflectance with prominent deep choroidal vessels, resulting in 100% sensitivity for the detection of retinopathy. Specificity of the imaging was 73.0% and 76.4% in the HCQ-taking control group and both control groups, respectively. Compared to FAF, retromode imaging enabled the detection of photoreceptor defects with greater sensitivity, particularly in eyes with early retinopathy. However, FAF provided additional information on the status of the retinal pigment epithelium, which could not be discriminated from photoreceptor defects in retromode imaging. CONCLUSIONS: Retromode imaging may be useful for detecting HCQ retinopathy. However, its excellent sensitivity but limited specificity is suggestive of a supplementary role in screening HCQ retinopathy, particularly for early detection.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Ahn SJ, Lee SU, Lee SH, et al. Evaluation of Retromode Imaging for Use in Hydroxychloroquine Retinopathy. Am J Ophthalmol. 2018. PMID: 30118686. doi:10.1016/j.ajo.2018.08.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。