文献速递眼底病与葡萄膜炎

中晚期年龄相关性黄斑变性暗适应检查最优参数研究

Determining Optimal Test Parameters for Assessing Dark Adaptation in People With Intermediate Age-Related Macular Degeneration.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2018-01-01

研究比较不同漂白浓度与偏心度下暗适应杆截距时间(RIT)对中晚期年龄相关性黄斑变性(iAMD)的诊断效能。76%漂白5°时iAMD组RIT显著延长且部分超过20分钟,76%漂白12°可保持相近区分度且恢复在20分钟内。

要点

  • 76%漂白5°时iAMD组RIT中位数20.6分钟,对照组5.8分钟,P=0.01。
  • 76%漂白12°时iAMD组RIT均值7.72分钟,对照组4.54分钟,P=0.03。
  • 76%漂白5°下45%的iAMD参与者RIT超过20分钟,其他条件无此现象。

核心结论

  • 76%漂白5°偏心度下近半数iAMD参与者恢复时间超过20分钟,临床可接受性差。
  • 76%漂白12°偏心度可保持与5°相近的AMD与对照区分度,且恢复时间在20分钟内。

研究设计与样本

  • 招募年龄>55岁的AMD患者与年龄相似对照,共26名参与者完成两次访视。
  • 在5°偏心度采用76%、70%、65%漂白,在12°偏心度采用76%、70%漂白评估杆截距时间(RIT)。
  • 测试顺序随机化,测试间设30分钟洗脱期,构建受试者工作特征(ROC)曲线。

主要发现

  • 76%漂白5°时对照组RIT中位数5.8分钟(IQR 3.8-7.5),iAMD组20.6分钟(IQR 11.1-30.0),Mann-Whitney检验P=0.01。
  • 76%漂白12°时对照组RIT均值4.54分钟(SD 2.12),iAMD组7.72分钟(SD 3.37),独立样本t检验P=0.03。
  • iAMD组5名参与者(45%)在76%漂白5°下RIT>20分钟,其他测试条件无此情况。

临床怎么用

  • 评估iAMD暗适应时可优先考虑76%漂白12°偏心度,以兼顾诊断敏感性与测试时长。
  • 76%漂白5°因较多iAMD患者恢复超过20分钟,可能不适合作为常规测试条件。

局限性

  • 样本量较小,共26名参与者。
  • 参与者为可变黄斑健康等级,iAMD组具体分级构成未在摘要中报告。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The primary aim was to determine optimal test conditions for evaluating dark adaptation in intermediate age-related macular degeneration (iAMD) in order to minimize test time while maintaining diagnostic sensitivity. METHODS: People with AMD and age-similar controls were recruited (aged >55 years). Rod intercept time (RIT) was assessed after a 76%, 70%, and 65% rhodopsin bleach at 5° eccentricity and 76% and 70% bleach at 12°. Test order was randomized and a 30-minute washout period added between tests. Results were compared between control and iAMD groups and receiver operating characteristics (ROC) curves were constructed. RESULTS: A total of 26 participants with variable grades of macular health attended for two visits. There was a statistically significant difference in average RIT between the control and iAMD groups at 5° (median, IQR controls = 5.8 minutes, 3.8-7.5; iAMD = 20.6 minutes, 11.1-30.0; Mann-Whitney, P = 0.01) and at 12° (mean, controls: 4.54 minutes ± 2.12 SD, iAMD = 7.72 minutes ± 3.37 SD; independent samples t-test, P = 0.03) following a 76% bleach. Area under the ROC curves was 0.83 (confidence interval [CI]: 0.64-1.0) and 0.79 (CI: 0.59-0.99) for these two test conditions, respectively. Five participants (45%) in the iAMD group had RITs >20 minutes for 76% bleach at 5°, but none for any other test condition. CONCLUSIONS: Nearly half of the participants with iAMD produced unacceptably long recovery times (>20 minutes) using a 76% bleach at 5° eccentricity. The 76% bleach at 12° provided almost equivalent separation between AMD and controls but recovery was achieved within 20 minutes.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Binns AM, Taylor DJ, Edwards LA, et al. Determining Optimal Test Parameters for Assessing Dark Adaptation in People With Intermediate Age-Related Macular Degeneration. Invest Ophthalmol Vis Sci. 2018. PMID: 30105357. doi:10.1167/iovs.18-24211

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。