视网膜下玻璃膜疣样沉积与中期年龄相关性黄斑变性视杆细胞功能丧失
这项横断面研究用暗适应色觉视野计比较对照组、无SDD的iAMD眼和有SDD的iAMD眼在光漂白前后的静态视杆功能。结果显示有SDD的iAMD眼平均PWSD显著降低,且仅局限于中央8°、光漂白后更明显;无SDD的iAMD眼仅在光漂白后较对照组降低。
要点
- 有SDD的iAMD眼静态视杆功能较无SDD眼和对照组更差。
- 视杆功能异常以中央8°内最明显,光漂白后检测更敏感。
- 无SDD的iAMD眼仅在光漂白后PWSD较对照组降低。
核心结论
- 有SDD的iAMD眼与较差的静态视杆功能相关,异常以中央8°内和光漂白后检测最明显。
研究设计与样本
- 用暗适应色觉视野计在中央24°内以505nm和625nm刺激检测视网膜敏感度,暗适应30分钟后分别在有或无光漂白条件下测试。
- 采用多模态影像对AMD和SDD状态及进展为晚期AMD的其他危险因素进行分级。
主要发现
- SDD组平均PWSD较对照组(P < 0.001)和无SDD组(P < 0.001)显著降低,但仅限中央8°内。
- 无SDD组平均PWSD较对照组降低,但仅见于有光漂白的测量(P = 0.020)。
- 在无SDD的iAMD眼(P = 0.60)和有SDD的iAMD眼(P = 0.12)中,有无高反射灶和/或新生地图样萎缩的平均PWSD无差异。
关键数值与推荐
- 视杆功能以505nm与625nm刺激间的敏感度差值(PWSD)评估,比较各组平均PWSD。
- SDD组平均PWSD较对照组和无SDD组降低均P < 0.001,仅限中央8°。
- 无SDD组较对照组平均PWSD降低仅见于光漂白后测量,P = 0.020。
临床怎么用
- 对iAMD患者可关注SDD的存在,其提示中央8°内静态视杆功能更差。
- 评估iAMD视杆功能时,光漂白后暗适应色觉视野检测可能更敏感。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare static rod function obtained with and without photobleach in control and intermediate age-related macular degeneration (iAMD) participants with and without subretinal drusenoid deposits (SDD). METHODS: In this cross-sectional study, retinal sensitivities within the central 24° retina were obtained twice using a dark-adapted chromatic perimeter, both with 505- and 625-nm stimuli. Tests were performed after 30 minutes of dark-adaptation either with or without a preceding photobleach. Multimodal imaging was performed to grade AMD and SDD status, and other retinal changes considered being risk factors for progression to late AMD. The sensitivity difference between both stimuli was used to assess rod function. The average point wise sensitivity difference (PWSD) was compared among the study groups. RESULTS: Twenty-nine control subjects and 20 iAMD without SDD and 17 iAMD with SDD cases were recruited. The average PWSD of the SDD group was significantly reduced (more with photobleach) compared with that of the control (P < 0.001) and no-SDD groups (P < 0.001), but only within the central 8°. The average PWSD of the non-SDD group was also reduced compared with the control group but only for measurements with photobleach (P = 0.020). There was no difference in average PWSD between the presence and absence of hyperreflective foci and/or nascent geographic atrophy in iAMD eyes without SDD (P = 0.60) or with SDD (P = 0.12). CONCLUSIONS: iAMD eyes with SDD are associated with worse static rod function compared with eyes without SDD. The greatest abnormality in rods is observed within the central 8° and when tested with a preceding photobleach.
引用
- Tan R, Guymer RH, Luu CD, et al. Subretinal Drusenoid Deposits and the Loss of Rod Function in Intermediate Age-Related Macular Degeneration. Invest Ophthalmol Vis Sci. 2018. PMID: 30105370. doi:10.1167/iovs.18-23970
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。