文献速递角膜与眼表疾病

SPEED问卷与CLDEQ-8的心理测量学分析

Psychometric Analysis of the SPEED Questionnaire and CLDEQ-8.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2018-01-01

本研究评估SPEED问卷在接触镜(CL)和非接触镜佩戴者中检测干眼症状的能力,并对CL佩戴者施测CLDEQ-8。Rasch分析得出8条目SPEED多维简版和4条目CLDEQ-8单维简版,两者得分均与自报干眼显著相关,但8条目SPEED得分仅与非CL佩戴者的干眼病状态相关,4条目CLDEQ得分仅与CL佩戴者的干眼病状态相关。

要点

  • 8条目SPEED简版量化多类症状,4条目CLDEQ-8简版主要量化干眼症状。
  • 两问卷得分均与自报干眼显著相关,可能适用于两类人群。
  • 泪河高度和酚红棉线试验与两问卷得分均无关联。

核心结论

  • 8条目SPEED问卷测量精度 adequate,可量化多个症状类别;4条目CLDEQ-8主要量化干眼症状。
  • 问卷得分与自报干眼相关,提示在CL和非CL佩戴者中均可能有实用价值。

研究设计与样本

  • 纳入284名受试者(150名CL佩戴者,134名非CL佩戴者),平均年龄39.4±14.2岁。
  • 所有受试者完成SPEED问卷,仅CL佩戴者完成CLDEQ-8;测量泪河高度并行酚红棉线试验。
  • 采用Rasch分析评估问卷的测量精度和单维性,并用其得分预测干眼病指标。

主要发现

  • Rasch分析得出8条目多维简版SPEED问卷和4条目单维简版CLDEQ-8。
  • 两问卷得分均与CL和非CL佩戴者的自报干眼显著相关。
  • 8条目SPEED得分与非CL佩戴者的干眼病状态相关,但与CL佩戴者无关。
  • 4条目CLDEQ得分与CL佩戴者的干眼病状态相关。
  • 泪河高度或酚红棉线试验与两问卷在CL或非CL佩戴者中均无关联。

临床怎么用

  • 在接触镜佩戴者中可考虑使用4条目CLDEQ-8简版评估干眼症状。
  • 在非接触镜佩戴者中可考虑使用8条目SPEED简版评估多类干眼症状。
  • 问卷得分反映自报干眼症状,但不能替代泪河高度或酚红棉线等客观干眼指标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study reports on the ability of the Standard Patient Evaluation of Eye Dryness (SPEED) questionnaire to detect dry eye (DE) symptoms in contact lens (CL) and non-CL wearers. METHODS: The SPEED questionnaire was administered to all subjects while the Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) was only administered to CL wearers. Tear meniscus heights (TMH) were measured, and the phenol red thread (PRT) test was conducted. These tests along with self-reported DE were used to identify subjects with dry eye disease (DED). Rasch analysis was performed to evaluate the questionnaires for measurement precision and unidimensionality, and the scores from these Rasch analyses were used to understand their ability to predict measures of DED. RESULTS: We enrolled 284 subjects (150 CL and 134 non-CL wearers). Mean subject age was 39.4 ± 14.2 years. Rasch analysis yielded a multidimensional short form of the SPEED questionnaire (8-items) and a unidimensional short form of the CLDEQ-8 (4-item). Scores from both questionnaires were significantly associated with self-reported DE in CL and non-CL wearers. Scores of the 8-item SPEED questionnaire were associated with DED status in non-CL wearers but not in CL wearers while 4-item CLDEQ scores were associated with DED status in CL wearers. TMH or PRT were not associated with either questionnaire in CL or non-CL wearers. CONCLUSIONS: The 8-item SPEED questionnaire demonstrated adequate measurement precision with evidence of quantifying multiple symptoms categories while the 4-item CLDEQ-8 primarily quantified DE symptoms. Questionnaire scores were associated with self-reported DE, which suggests that they may have utility in both populations analyzed.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Pucker AD, Dougherty BE, Jones-Jordan LA, et al. Psychometric Analysis of the SPEED Questionnaire and CLDEQ-8. Invest Ophthalmol Vis Sci. 2018. PMID: 30025086. doi:10.1167/iovs.18-24016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。