PubMed 文献 · Invest Ophthalmol Vis Sci · 2018-01-01

该前瞻性病例系列纳入100只接受白内障手术的眼,按世界卫生组织分级评估白内障,用Spectralis MultiColor的MPOD模块在术前术后测量黄斑色素光密度(MPOD)。术前67只眼可获得MPOD;术后局部与容积MPOD均高于术前,局部校正因子为1.42至1.77、容积校正因子为1.31,年龄、核性白内障分级、后囊下混浊与图像质量指数显著影响校正因子,可用回归方程校正。

要点

  • 白内障会压低Spectralis-MP测得的MPOD,术后MPOD高于术前。
  • 局部MPOD校正因子为1.42至1.77,越靠近中心凹所需校正因子越大。
  • 年龄、核性白内障分级、后囊下混浊与图像质量指数显著影响校正因子,可用回归方程校正。

核心结论

  • 白内障影响Spectralis-MP的MPOD测量,但可通过回归方程获得校正后的MPOD结果。

研究设计与样本

  • 前瞻性病例系列,纳入100只接受白内障手术的眼,按世界卫生组织分类进行白内障分级。
  • 术前术后用Spectralis MultiColor仪器的MPOD模块测量MPOD,评估黄斑区四个选定偏心度的局部MPOD及中心8.98°范围内的总MPOD容积。

主要发现

  • 术前67只眼可获得MPOD测量。
  • 所有眼术后局部与容积MPOD均高于术前。
  • 术后与术前局部MPOD均值比为校正因子(CF),范围为1.42至1.77,越靠近中心凹所需CF越大。
  • MPOD容积的CF为1.31。
  • 年龄、核性白内障(NUC)分级、后囊下混浊与图像质量指数(IQI)显著影响CF。

关键数值与推荐

  • 0.23°处CF的回归方程:CF = 0.17 + 0.16 × IQI + 0.29 × NUC分级 + 0.01 × 年龄(P < 0.001)。
  • 局部MPOD校正因子范围为1.42至1.77,MPOD容积校正因子为1.31。
  • 总MPOD容积在距中心8.98°偏心度范围内评估。

临床怎么用

  • 对合并白内障的眼测量MPOD时,可依据年龄、NUC分级、后囊下混浊与IQI用回归方程校正白内障的影响。
  • 越靠近中心凹的局部MPOD受白内障影响越大,解读时需按偏心度选用相应校正因子。

局限性

  • 术前仅67只眼可获得MPOD测量,样本可用性受限。
  • 本文未报告回归方程之外的验证数据或外部验证结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the influence of cataracts on measuring macular pigment optical density (MPOD) using a dual-wavelength confocal scanning autofluorescence imaging technique and to establish methods to compensate for the influence of cataracts. METHODS: This prospective case series comprised 100 eyes that underwent cataract surgery. Cataracts were graded based on the World Health Organization classification. MPOD levels were measured with the MPOD module of the Spectralis MultiColor instrument (Spectralis-MP), pre- and postoperatively. We investigated the relationship between change in MPOD values and age, cataract grade, and quality of autofluorescence images. Local MPOD levels were evaluated for four strategically chosen eccentricities within the macular region, and the total MPOD volume was evaluated within 8.98° eccentricity from the center. RESULTS: MPOD levels could be obtained in 67 eyes before surgery. Local and volume MPOD levels were higher postoperatively relative to preoperatively in all eyes. The mean ratio of local MPOD levels after and before surgery (correction factor, CF) ranged from 1.42 to 1.77, with larger CFs required for eccentricities closer to the foveal center. The CF for the MPOD volume was 1.31. Age, grade of nuclear cataract (NUC), posterior subcapsular opacity, and image quality index (IQI) significantly contributed to CFs. For example, regression equation for CF at 0.23° = 0.17 + 0.16 × IQI + 0.29 × NUC grade + 0.01 × age (P < 0.001). CONCLUSIONS: Cataracts affected MPOD measurements with the Spectralis-MP, but corrected MPOD results could be obtained via regression equations.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Obana A, Gohto Y, Sasano H, et al. Grade of Cataract and Its Influence on Measurement of Macular Pigment Optical Density Using Autofluorescence Imaging. Invest Ophthalmol Vis Sci. 2018. PMID: 30025122. doi:10.1167/iovs.17-23699

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。