研究用高分辨率眶部磁共振成像比较内斜视、外斜视、上斜视与正常对照在中央注视及最大内收、外展时视神经鞘拴系和眼球平移情况。结果发现内斜视和上斜视内收时视神经鞘拴系与正常相似,外斜视则未出现,可能与内收角度受限有关。

要点

  • 内斜视和上斜视内收时视神经鞘拴系与正常相似,且无眼球内陷。
  • 外斜视内收时未出现视神经鞘拴系,可能因内收角度显著小于正常。
  • 外斜视内收时眼球鼻侧平移显著小于正常,内斜视和上斜视外展时颞侧平移也显著小于正常。

核心结论

  • 内斜视和上斜视内收时视神经及鞘发生拴系且无眼球内陷,与正常受试者相似。
  • 外斜视内收时视神经鞘拴系不发生,可能由于内收角度受限。
  • 限制内收可考虑作为视神经鞘拴系的潜在治疗方法。

研究设计与样本

  • 采用表面线圈在2毫米厚准冠状面获取高分辨率眶部磁共振成像。
  • 纳入25例内斜视(49眼眶)、11例外斜视(15眼眶)、7例上斜视(12眼眶)和31例正常对照(62眼眶)。
  • 在靶控中央注视、最大可及外展和内收状态下成像,用面积质心确定视神经路径弯曲度和眼球位置。

主要发现

  • 内斜视内收角度30.6°±0.9°,上斜视27.2°±2.3°,与正常28.3°±0.7°无显著差异。
  • 外斜视内收角度19.0°±2.5°,显著小于正常(P=0.005)。
  • 外斜视内收时眼球鼻侧平移显著小于正常,内斜视和上斜视外展时颞侧平移显著小于正常(所有P<0.02)。
  • 任何组在外展或内收时均未出现眼球内陷。

临床怎么用

  • 对于内斜视和上斜视患者,内收时视神经鞘拴系与正常相似,提示这些人群可能存在类似的视神经机械应力。
  • 外斜视患者内收时视神经鞘未拴系,可能与内收角度受限有关,限制内收或可作为视神经鞘拴系的潜在治疗方向。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Repetitive strain to the optic nerve (ON) due to tethering in adduction has been recently proposed as an intraocular pressure-independent mechanism of optic neuropathy in primary open-angle glaucoma. Since strabismus may alter adduction, we investigated whether gaze-related ON straightening and associated globe translation differ in horizontal and vertical strabismus. METHODS: High-resolution orbital magnetic resonance imaging was obtained in 2-mm thick quasi-coronal planes using surface coils in 25 subjects (49 orbits) with esotropia (ET, 19 ± 3.6Δ SEM), 11 (15 orbits) with exotropia (XT, 33.7 ± 7.3Δ), 7 (12 orbits) with hypertropia (HT, 14.6 ± 3.2Δ), and 31 normal controls (62 orbits) in target-controlled central gaze, and in maximum attainable abduction and adduction. Area centroids were used to determine ON path sinuosity and globe positions. RESULTS: Adduction angles achieved in ET (30.6° ± 0.9°) and HT (27.2° ± 2.3°) did not significantly differ from normal (28.3° ± 0.7°), but significantly less adduction was achieved in XT (19.0° ± 2.5°, P = 0.005). ON sheath tethering in adduction occurred in ET and HT similarly to normal, but did not in XT. The globe translated significantly less than normal, nasally in adduction in XT and temporally in abduction in ET and HT (P < 0.02, for all). Globe retraction did not occur during abduction or adduction in any group. CONCLUSIONS: Similar to normal subjects, the ON and sheath become tethered without globe retraction in ET and HT. In XT, adduction tethering does not occur, possibly due to limited adduction angle. Thus, therapeutic limitation of adduction could be considered as a possible treatment for ON sheath tethering.