PubMed 文献 · Invest Ophthalmol Vis Sci · 2018-01-01

该研究基于疑似或已确诊青光眼参与者的标准自动视野计纵向数据,对24-2视野每个位置拟合异质固定效应模型,假设变异性随敏感度下降呈指数增加。结果显示所有52个位置变异性均随损伤显著增加;敏感度为30 dB时变异性随偏心度增加,敏感度为25 dB时无此规律。结论认为敏感度与变异性的关系因偏心度而异。

要点

  • 所有52个视野位置变异性随敏感度下降显著增加。
  • 敏感度30 dB时变异性随偏心度增加,中央平均SD 1.54 dB低于周边1.74 dB。
  • 敏感度25 dB时变异性与偏心度无预测性关系(P=0.340)。

核心结论

  • 敏感度与变异性的关系因偏心度而异,健康位置中央变异性低于周边,受损位置无系统偏心度差异。

研究设计与样本

  • 从疑似或已确诊青光眼参与者获取标准自动视野计纵向视野序列。
  • 对24-2视野每个位置拟合异质固定效应模型,假设变异性随敏感度下降呈指数增加。

主要发现

  • 所有52个位置变异性随损伤显著增加。
  • 敏感度30 dB时变异性随偏心度增加(P=0.0003),最中央四个位置平均SD 1.54 dB,最周边位置1.74 dB。
  • 敏感度25 dB时变异性与偏心度无预测性关系(P=0.340),最中央四个位置平均SD 2.36 dB,最周边位置2.24 dB。

关键数值与推荐

  • 敏感度30 dB时,最中央四个位置平均SD 1.54 dB,最周边位置1.74 dB。
  • 敏感度25 dB时,最中央四个位置平均SD 2.36 dB,最周边位置2.24 dB。
  • 敏感度30 dB时变异性与偏心度关系P=0.0003;敏感度25 dB时P=0.340。

临床怎么用

  • 解读青光眼视野时需考虑偏心度对敏感度-变异性关系的影响。
  • 中央与周边位置在健康状态下变异性不同,评估损伤时不宜统一阈值。

局限性

  • 摘要未报告样本量、随访时长及具体统计模型细节。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Perimetric sensitivities become more variable with glaucomatous functional loss. This study examines the extent to which this relation varies between locations, and whether this can be predicted by eccentricity-related differences in spatial summation. METHODS: Longitudinal series of visual fields from standard automated perimetry were obtained from participants with suspected or extant glaucoma. For each location in the 24-2 visual field, heterogeneous fixed-effects models were fit to the data, assuming that variability increased exponentially as sensitivity decreased. The predicted variability at each location was calculated when sensitivity was either 30 dB or 25 dB. RESULTS: Variability significantly increased with damage at all 52 locations. When sensitivity was 30 dB, variability increased with eccentricity, with P = 0.0003. The average SD was 1.54 dB at the four most central locations, versus 1.74 dB at the most peripheral locations. When sensitivity was 25 dB, variability did not vary predictably with eccentricity, with P = 0.340. The average SD was 2.36 dB at the four central locations, versus 2.24 dB at the most peripheral locations. CONCLUSIONS: The relation between sensitivity and variability differed by eccentricity. Among healthy locations, variability was lower centrally, where the stimulus size is larger than Ricco's area, than peripherally. Among damaged locations, variability did not systematically vary with eccentricity. This could be because Ricco's area expands in glaucoma, such that stimuli were now smaller than this area at all locations.