视网膜变性中黄斑中心凹视锥细胞结构与自适应光学视觉 acuity 的关系
本研究使用自适应光学扫描激光检眼镜(AOSLO)测量4名健康受试者和15名遗传性视网膜变性(IRD)患者的黄斑中心凹视锥细胞间距,并评估其与视力(VA)及黄斑敏感度的相关性。结果显示ETDRS-VA与AOSLO-VA显著相关(ρ=0.79),视锥细胞间距与AOSLO-VA相关(ρ=0.54),与ETDRS字母数负相关(ρ=-0.64);AOSLO-VA和ETDRS-VA在视锥细胞密度低于正常约40%-42%前保持≥20/20。结论提示VA是黄斑视锥细胞存活的不敏感指标,视锥细胞间距可能更敏感。
要点
- ETDRS-VA与AOSLO-VA显著相关(ρ=0.79,95%CI 0.5-0.9)。
- 视锥细胞间距与AOSLO-VA相关(ρ=0.54),与ETDRS字母数负相关(ρ=-0.64)。
- AOSLO-VA和ETDRS-VA在视锥细胞低于正常约40%-42%前保持≥20/20。
核心结论
- VA与黄斑中心凹视锥细胞间距仅弱相关,直至视锥细胞低于正常40%至43%。
- VA是黄斑视锥细胞存活的不敏感指标,视锥细胞间距可能更敏感地反映视锥细胞丢失。
研究设计与样本
- 使用AOSLO对4名健康受试者和15名IRD患者进行黄斑中心凹视锥细胞成像。
- 通过840 nm扫描激光投射「E」视标测量AOSLO介导的视力(AOSLO-VA)。
- 由两名独立评分者测量 preferred retinal locus 的视锥细胞间距,并计算低于47名年龄相似健康受试者平均密度的视锥细胞百分比。
主要发现
- ETDRS-VA与AOSLO-VA显著相关(ρ=0.79,95%CI 0.5-0.9)。
- 视锥细胞间距与AOSLO-VA相关(ρ=0.54,95%CI 0.02-0.7),与ETDRS字母数负相关(ρ=-0.64,95%CI -0.8至-0.2)。
- AOSLO-VA在视锥细胞低于正常40.2%(95%CI 31.1-45.5)前保持≥20/20。
- ETDRS-VA在视锥细胞低于正常42.0%(95%CI 36.5-46.1)前保持≥20/20。
- 视锥细胞间距z评分与黄斑敏感度负相关(ρ=-0.79,95%CI -0.9至-0.4),黄斑敏感度在视锥细胞低于平均43.1%(95%CI 39.3-46.6)前保持≥35 dB。
关键数值与推荐
- ETDRS-VA与AOSLO-VA的相关系数ρ=0.79(95%CI 0.5-0.9)。
- 视锥细胞间距与AOSLO-VA的相关系数ρ=0.54(95%CI 0.02-0.7)。
- 视锥细胞间距与ETDRS字母数的相关系数ρ=-0.64(95%CI -0.8至-0.2)。
- AOSLO-VA保持≥20/20的视锥细胞密度阈值:低于正常40.2%(95%CI 31.1-45.5)。
- ETDRS-VA保持≥20/20的视锥细胞密度阈值:低于正常42.0%(95%CI 36.5-46.1)。
临床怎么用
- 在IRD患者中,ETDRS-VA与AOSLO-VA显著相关,可用于评估黄斑功能。
- 视锥细胞间距与VA及黄斑敏感度相关,可能作为视锥细胞丢失的更敏感指标。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate foveal function in patients with inherited retinal degenerations (IRD) by measuring visual acuity (VA) after correction of higher-order aberrations. METHODS: Adaptive optics scanning laser ophthalmoscopy (AOSLO) was used to image cones in 4 healthy subjects and 15 patients with IRD. The 840-nm scanning laser delivered an "E" optotype to measure AOSLO-mediated VA (AOSLO-VA). Cone spacing was measured at the preferred retinal locus by two independent graders and the percentage of cones below the average density of 47 age-similar healthy subjects was computed. Cone spacing was correlated with best-corrected VA measured with the Early Treatment of Diabetic Retinopathy Study protocol (ETDRS-VA), AOSLO-VA, and foveal sensitivity. RESULTS: ETDRS-VA significantly correlated with AOSLO-VA (ρ = 0.79, 95% confidence interval [CI] 0.5-0.9). Cone spacing correlated with AOSLO-VA (ρ = 0.54, 95% CI 0.02-0.7), and negatively correlated with ETDRS letters read (ρ = -0.64, 95% CI -0.8 to -0.2). AOSLO-VA remained ≥20/20 until cones decreased to 40.2% (CI 31.1-45.5) below normal. Similarly, ETDRS-VA remained ≥20/20 until cones were 42.0% (95% CI 36.5-46.1) below normal. Cone spacing z scores negatively correlated with foveal sensitivity (ρ = -0.79, 95% CI -0.9 to -0.4) and foveal sensitivity was ≥35 dB until cones were 43.1% (95% CI 39.3-46.6) below average. CONCLUSIONS: VA and foveal cone spacing were weakly correlated until cones were reduced by 40% to 43% below normal. The relationship suggests that VA is an insensitive measure of foveal cone survival; cone spacing may be a more sensitive measure of cone loss.
引用
- Foote KG, Loumou P, Griffin S, et al. Relationship Between Foveal Cone Structure and Visual Acuity Measured With Adaptive Optics Scanning Laser Ophthalmoscopy in Retinal Degeneration. Invest Ophthalmol Vis Sci. 2018. PMID: 30025078. doi:10.1167/iovs.17-23708
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。