文献速递眼底病与葡萄膜炎

视网膜疾病中OCTA血管密度测量的重复性

Repeatability of vessel density measurements using optical coherence tomography angiography in retinal diseases.
PubMed 文献 · Br J Ophthalmol · 2018-07-04

这项前瞻性研究分析了134只患有糖尿病黄斑水肿、视网膜静脉阻塞伴黄斑水肿、视网膜前膜或湿性年龄相关性黄斑变性的眼,连续两次OCTA血管密度测量的全血管密度ICC为0.812、CV为6.72%;单因素分析显示BCVA、信号强度、CMT和GC-IPL厚度影响重复性,多因素分析仅GC-IPL厚度显著。

要点

  • 四种视网膜疾病全血管密度测量的ICC为0.812,CV为6.72%。
  • 单因素分析显示BCVA、信号强度、CMT和GC-IPL厚度与重复性显著相关。
  • 多因素分析中仅GC-IPL厚度对重复性有显著影响。

核心结论

  • OCTA测量的血管密度在多种视网膜疾病中显示出相对较好的重复性。
  • BCVA、信号强度、CMT和GC-IPL厚度影响重复性,分析血管密度时应考虑这些因素。

研究设计与样本

  • 前瞻性分析视网膜疾病患者连续两次OCTA血管密度测量,共134只眼,包括DME 20只、RVO伴黄斑水肿44只、ERM 50只、湿性AMD 20只。
  • 评估ICC、CV和重测SD,并进行线性回归分析以确定与重复性相关的因素。

主要发现

  • 四种疾病全血管密度的ICC为0.812,CV为6.72%。
  • 单因素分析显示BCVA(B,8.553;p=0.031)、信号强度(B,-1.688;p=0.050)、CMT(B,0.019;p=0.015)和平均GC-IPL厚度(B,-0.103;p=0.001)是影响重复性的显著因素。
  • 多因素分析显示GC-IPL厚度对重复性有显著结果。
  • 平均年龄64.9岁,平均BCVA为0.24,平均CMT为391.6 µm,平均GC-IPL厚度为61.4 µm。

关键数值与推荐

  • 全血管密度ICC为0.812,CV为6.72%(四种疾病合计)。
  • BCVA的B值为8.553(p=0.031),信号强度的B值为-1.688(p=0.050),CMT的B值为0.019(p=0.015),平均GC-IPL厚度的B值为-0.103(p=0.001)。

临床怎么用

  • 分析OCTA血管密度时,应考虑BCVA、信号强度、CMT和GC-IPL厚度对测量重复性的影响。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To analyse the repeatability of vessel density (VD) measurements using optical coherence tomography angiography (OCTA) in patients with retinal diseases. METHODS: Two consecutive VD measurements using OCTA were analysed prospectively in patients with retinal diseases (diabetic macular oedema (DME), retinal vein occlusion (RVO) with macular oedema, epiretinal membrane (ERM), wet age-related macular degeneration (AMD)). The intraclass correlation coefficient (ICC), coefficient of variation (CV) and test-retest SD of VD measurements were assessed, and linear regression analyses were conducted to identify factors related to repeatability. RESULTS: A total of 134 eyes were analysed involving 20 eyes with DME, 44 eyes with RVO with macular oedema, 50 eyes with ERM and 20 eyes with wet AMD. The mean age was 64.9 years, and the mean best-corrected visual acuity (BCVA) was 0.24. The mean central macular thickness (CMT) was 391.6 µm, and the mean ganglion cell-inner plexiform layer (GC-IPL) thickness was 61.4 µm. In all four diseases, the ICC and CV of the full VD were 0.812 and 6.72%, respectively. Univariate analyses showed that the BCVA (B, 8.553; p=0.031), signal strength (B, -1.688; p=0.050), CMT (B, 0.019; p=0.015) and mean GC-IPL thickness (B, -0.103; p=0.001) were significant factors that affected the repeatability. Multivariate analyses of these factors showed a significant result for the GC-IPL thickness. CONCLUSIONS: Measurements of the VD using OCTA showed relatively good repeatability for various retinal diseases. The BCVA, signal strength, CMT and GC-IPL thickness affected the repeatability, so these factors should be considered when analysing the VD.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Lee MW, Kim KM, Lim HB, et al. Repeatability of vessel density measurements using optical coherence tomography angiography in retinal diseases. Br J Ophthalmol. 2018. PMID: 29973363. doi:10.1136/bjophthalmol-2018-312516

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。