双目OCT系统评估原在位斜视

Use of a Binocular Optical Coherence Tomography System to Evaluate Strabismus in Primary Position.
PubMed 文献 · JAMA Ophthalmol · 2018-01-01

该研究纳入15例斜视患者和15名健康志愿者,在斜视检查(APCT)后使用双目OCT原型机进行自动化前节成像,分析同时采集的OCT图像以评估斜视的存在和角度。结果显示双目OCT在所有15例斜视患者中正确识别偏斜类型和方向,水平与垂直偏斜的OCT测量值与APCT测量值强相关。

要点

  • 双目OCT在所有15例斜视患者中正确识别偏斜类型和方向,包括水平和垂直偏斜。
  • 水平偏斜OCT与APCT测量值强相关(Pearson r=0.85;95%CI 0.60-0.95;P<.001)。
  • 垂直偏斜OCT与APCT测量值强相关(Pearson r=0.89;95%CI 0.69-0.96;P<.001)。

核心结论

  • 双目前节OCT成像可为临床医生提供斜视的精确测量。
  • 该原型机有望整合多种双眼视觉测试,为眼位偏斜的评估、诊断和监测提供定量数据。

研究设计与样本

  • 2016年作为EASE研究的一部分,从英国伦敦Moorfields Eye Hospital NHS Foundation Trust招募15例斜视患者,另15名健康志愿者接受双目OCT原型机自动化前节成像。
  • 所有参与者先进行斜视检查包括交替棱镜遮盖试验(APCT),再行OCT成像。
  • 使用ImageJ分析单眼注视时同时采集的成对OCT图像,以评估斜视的存在和角度。

主要发现

  • 斜视患者中位年龄55岁(IQR 33-66.5岁),健康组中位年龄50岁(IQR 41-59岁);15名参与者(50%)为女性,25名参与者(83.3%)为白人。
  • 水平偏斜中位幅度为20∆(IQR 13-35∆),垂直偏斜中位幅度为3∆(IQR 0-5∆)。
  • 双目OCT成像在所有15例斜视患者中正确揭示偏斜类型和方向,包括水平和垂直偏斜。
  • APCT与OCT测量值在水平偏斜(Pearson r=0.85;95%CI 0.60-0.95;P<.001)和垂直偏斜(r=0.89;95%CI 0.69-0.96;P<.001)上强相关。
  • 健康组中9/15名参与者(60%)APCT显示隐性水平偏斜(中位幅度2∆,范围2-4∆),6名(40%)为正位;OCT成像显示12/15名参与者(80%)存在水平偏斜,1名参与者(6.7%)可见垂直偏斜。

临床怎么用

  • 双目前节OCT成像可客观、自动化地评估和量化斜视,提供与APCT强相关的测量值。
  • 该原型机有望整合多种双眼视觉测试,为眼位偏斜的评估、诊断和监测提供定量数据。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

IMPORTANCE: Current clinical methods for assessing strabismus can be prone to error. Binocular optical coherence tomography (OCT) has the potential to assess and quantify strabismus objectively and in an automated manner. OBJECTIVE: To evaluate the use of a binocular OCT prototype to assess the presence and size of strabismus. DESIGN, SETTING, AND PARTICIPANTS: Fifteen participants with strabismus were recruited in 2016 as part of the EASE study from Moorfields Eye Hospital National Health Service Foundation Trust, London, England, and 15 healthy volunteers underwent automated anterior segment imaging using the binocular OCT prototype. All participants had an orthoptic assessment, including alternating prism cover test (APCT), before undergoing imaging. Simultaneously acquired pairs of OCT images, captured with 1 eye fixating, were analyzed using ImageJ (National Institutes of Health) to assess the presence and angle of strabismus. MAIN OUTCOMES AND MEASURES: The direction and size of strabismus measured using binocular OCT was compared with that found using APCT. RESULTS: The median age for participants with strabismus was 55 years (interquartile range [IQR], 33-66.5 years) and for the healthy group, 50 years (IQR, 41-59 years); 15 participants (50%) were women, and 25 participants (83.3%) were white. The median magnitude of horizontal deviation was 20∆ (IQR, 13-35∆) and for vertical deviation, 3∆ (IQR, 0-5∆). Binocular OCT imaging correctly revealed the type and direction of the deviation in all 15 participants with strabismus, including horizontal and vertical deviations. The APCT and OCT measurements were strongly correlated for the horizontal (Pearson r = 0.85; 95% CI, 0.60-0.95; P < .001) and vertical (r = 0.89; 95% CI, 0.69-0.96; P < .001) deviations. In the healthy cohort, 9 of 15 participants (60%) had a latent horizontal deviation on APCT results (median magnitude 2∆, range 2-4∆). Six (40%) had orthophoria. Horizontal deviations were observed on OCT imaging results in 12 of the 15 participants (80%), and a vertical deviation was visible in 1 participant (6.7%). CONCLUSIONS AND RELEVANCE: These findings suggest that binocular anterior segment OCT imaging can provide clinicians with a precise measurement of strabismus. The prototype can potentially incorporate several binocular vision tests that will provide quantitative data for the assessment, diagnosis, and monitoring of ocular misalignments.