泪膜动力学对视觉质量的影响
本文综述泪膜动力学如何影响视觉质量。泪膜作为眼的第一折射成分,其动力学变化可导致视觉和眼表症状;波前传感器可客观量化泪膜诱导的光学像差,2007年干眼工作坊报告已将视觉障碍纳入干眼病定义。综述聚焦泪膜质量、数量和性质三方面引起的波前变异机制。
要点
- 泪膜是眼的第一折射成分,其动力学变化可导致视觉和眼表症状。
- 波前传感器可客观量化泪膜诱导的光学像差,为干眼的光学质量评估提供客观方法。
- 2007年干眼工作坊报告已将视觉障碍纳入干眼病定义。
核心结论
- 泪膜动力学变化可导致视觉和眼表症状,波前传感器可客观量化泪膜诱导的光学像差。
研究设计与样本
- 综述,聚焦泪膜动力学引起波前变异的机制,涵盖泪膜质量、数量和性质三方面。
主要发现
- 泪膜动力学改变可导致视觉相关和眼表相关症状。
- 波前传感器可客观测量并量化泪膜诱导的光学像差。
- 连续测量波前像差可揭示与泪膜动力学相关的动态光学变化。
- 综述分别展示了干眼、溢泪和滴眼液滴入对视觉质量的影响。
关键数值与推荐
- 2007年干眼工作坊报告将视觉障碍纳入干眼病定义。
临床怎么用
- 波前传感器可用于客观评估干眼患者的光学质量。
- 连续波前像差测量可用于观察泪膜动力学相关的动态光学变化。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The precorneal tear film is maintained by blinking and exhibits different phases in the tear cycle. The tear film serves as the most anterior surface of the eye and plays an important role as a first refractive component of the eye. Alterations in tear film dynamics may cause both vision-related and ocular surface-related symptoms. Although the optical quality associated with the tear film dynamics previously received little attention, objective measurements of optical quality using wavefront sensors have enabled us to quantify optical aberrations induced by the tear film. This has provided an objective method for assessing reduced optical quality in dry eye; thus, visual disturbances were included in the definition of dry eye disease in the 2007 Dry Eye Workshop report. In addition, sequential measurements of wavefront aberrations have provided us with valuable insights into the dynamic optical changes associated with tear film dynamics. This review will focus on the current knowledge of the mechanisms of wavefront variations that are caused by different aspects of tear film dynamics: specifically, quality, quantity and properties of the tear film, demonstrating the respective effects of dry eye, epiphora and instillation of eye drops on the quality of vision.
引用
- Koh S, Tung CI, Inoue Y, et al. Effects of tear film dynamics on quality of vision. Br J Ophthalmol. 2018. PMID: 29907632. doi:10.1136/bjophthalmol-2018-312333
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。