缝线套索技术用于人工晶状体及囊袋张力装置巩膜固定
本文描述一种缝线套索技术:用26G针载Gore-Tex缝线制作套索,在巩膜固定部位安全回收Gore-Tex缝线,避免眼内操作粗大弯针,无需大巩膜切口,成本低,可联合Hoffman角膜巩膜袋。
要点
- Gore-Tex缝线比聚丙烯10-0更抗断裂,但针粗且过度弯曲,眼内操作有损伤风险。
- 用26G针载Gore-Tex缝线制作套索,经巩膜固定部位插入,从主切口引出线环。
- 套索回收载装置缝线至巩膜固定部位,避免不适当针和大巩膜切开,成本低。
核心结论
- 缝线套索技术可安全回收Gore-Tex缝线至巩膜固定部位,避免眼内操作粗大弯针及大巩膜切开。
研究设计与样本
- 本文为技术描述,未报告研究设计与样本量。
主要发现
- 26G针载Gore-Tex缝线制作套索,经巩膜固定部位插入,线环从主切口引出。
- 套索用于将载装置的Gore-Tex缝线端回收至巩膜固定部位。
- 该技术无需不适当针和大巩膜切开,成本低,可联合Hoffman角膜巩膜袋。
关键数值与推荐
- Gore-Tex缝线比聚丙烯10-0更抗断裂。
- 使用26G针载Gore-Tex缝线制作套索。
- 1 cc注射器作为手柄固定针座处缝线。
临床怎么用
- 在巩膜固定部位插入载缝线26G针,从主切口引出线环形成套索。
- 用套索回收载装置Gore-Tex缝线端至巩膜固定部位。
- 可联合Hoffman角膜巩膜袋进行巩膜固定。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Polytetrafluoroethylene (Gore-Tex) suture is preferred for scleral fixation of intraocular lenses or capsular tension devices as it is more resilient to breakage than polypropylene 10-0. However, manipulation of the thick calibre and overcurved configuration of the Gore-Tex needle within the eye poses a risk of damage to the intraocular structures. Existing techniques that overcome the problem of needles within the anterior chamber involve special instruments to retrieve the suture. We describe a technique that creates a suture snare from a short segment of the Gore-Tex suture borne on a 26-gauge needle, which is used to retrieve the Gore-Tex suture safely at the scleral fixation site. The suture is threaded into the bore of the needle leaving a short length extending from the hub which is secured by inserting a 1 cc syringe acting as a handle. The needle is inserted at the scleral fixation site, and the suture trailing from the needle tip forms a loop which is externalised at the main incision. This suture snare is used to retrieve the end of the Gore-Tex suture bearing the device to the scleral fixation site when the needle and the loop of the suture are withdrawn from the eye. This technique eliminates the inappropriate needle and the need for a large sclerostomy, and is cost-effective and can also be used in combination with the conjunctival-sparing Hoffman corneoscleral pocket.
引用
- Chee SP, Chan NS. Suture snare technique for scleral fixation of intraocular lenses and capsular tension devices. Br J Ophthalmol. 2018. PMID: 29891735. doi:10.1136/bjophthalmol-2018-311868