健康与圆锥角膜(含/不含交联)生物力学评估及参数(A1L-A2L)相关性
新参数A1L-A2L可区分交联与未交联及健康角膜,A2V和A2L也有助于鉴别。Corvis ST或可用于监测交联疗效。
要点
- A1L-A2L在交联角膜与未交联圆锥角膜及健康角膜间差异高度显著。
- A2V和DA在交联圆锥角膜中较未交联组和健康对照组均显著增加。
- 随访分析显示角膜厚度和眼压有统计学显著变化。
核心结论
- A2V和A2L均可区分健康与圆锥角膜以及交联与非交联圆锥角膜。
- A1L-A2L差值可可靠区分交联与未交联及健康角膜。
- Corvis ST似乎提供监测交联治疗成功的有用技术。
研究设计与样本
- 另对10例圆锥角膜患者分别在CXL治疗前后进行检查。
- 使用超高速Scheimpflug技术(Corvis ST)进行角膜生物力学测量。
主要发现
- 新参数A1L-A2L在交联角膜与未交联圆锥角膜或健康角膜之间显示高度显著差异。
- 第二压平速度(A2V)和形变幅度(DA)在交联圆锥角膜眼中较未交联圆锥角膜眼和健康对照均显著增加。
- 最高曲率半径在所有组间也显著。
- 向内压平长度(A1L)在对照组显著增加,而向外压平长度(A2L)在交联圆锥角膜眼较其他两组显著降低。
- 随访分析显示角膜厚度和眼压有统计学显著变化,压平时间1和2及DA呈接近显著的倾向。
临床怎么用
- Corvis ST测量的角膜形变可重复,为圆锥角膜评估和生物力学提供有用信息。
- A1L-A2L差值可用于区分交联与未交联及健康角膜。
- Corvis ST似乎可用于监测交联治疗的效果。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: To examine corneal biomechanics in healthy and keratoconic eyes, with or without crosslinking obtained by ultrahigh-speed Scheimpflug measurements (Corvis ST). METHODS: One hundred and seventeen eyes were studied in three groups: group 1 (n=39) contained keratoconic eyes without crosslinking. Group 2 (CXL; n=28) comprised keratoconic eyes after crosslinking. These were compared with a control group (n=50 matched healthy eyes). In addition, 10 keratoconus patients, before and after CXL treatment, respectively, were examined. RESULTS: The novel parameter A1L-A2L demonstrated highly significant differences between crosslinked corneas and untreated keratoconic or healthy corneas. Velocity during second applanation (A2V) and deformation amplitude (DA) were significantly increased in crosslinked keratoconic eyes both compared with untreated keratoconic eyes and with healthy controls. Radius at highest curvature also was significant among all groups. Inward applanation length (A1L) was significantly increased in controls, whereas outward applanation length (A2L) was significantly reduced in crosslinked keratoconic eyes compared with both other groups. The follow-up analysis revealed statistically significant changes in pachymetry and intraocular pressure and showed tendencies towards significance in applanation times 1 and 2 and in DA. CONCLUSIONS: Both A2V and A2L are viable parameters to discriminate healthy from keratoconic but also crosslinked from non-crosslinked keratoconic corneas. The difference of A1L-A2L could reliably discriminate crosslinked from non-crosslinked and healthy corneas. Follow-up examination in a small cohort allows distinction between crosslinked and untreated keratoconus in follow-up examinations. The difference of A1L-A2L could reliably discriminate crosslinked from non-crosslinked and healthy corneas. Measurements of corneal deformation using dynamic ultrahigh-speed Scheimpflug technology are reproducible and provide useful information about keratoconus assessment and biomechanics. Therefore, the Corvis ST seems to provide useful technology to monitor therapeutic success of crosslinking treatment.
引用
- Fuchsluger TA, Brettl S, Geerling G, et al. Biomechanical assessment of healthy and keratoconic corneas (with/without crosslinking) using dynamic ultrahigh-speed Scheimpflug technology and the relevance of the parameter (A1L-A2L). Br J Ophthalmol. 2018. PMID: 29871966. doi:10.1136/bjophthalmol-2017-311627
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。