文献速递青光眼

Kahook双刃小梁切开术获取小梁网的组织学分析

Histologic Analysis of Trabecular Meshwork Obtained From Kahook Dual Blade Goniotomy.
PubMed 文献 · Am J Ophthalmol · 2018-06-05

术后眼压和青光眼药物数量均显著下降(P<.0001,P=.035),标本中小梁网组织获取率高于传统外路小梁切除术的报道值(71% vs 20%)。

要点

  • KDB小梁切开术获取的小梁网组织学标本中,小梁网组织获取率为71%,高于传统外路小梁切除术报道的20%。
  • 术后所有病例眼压和青光眼药物数量均显著下降(P<.0001,P=.035)。
  • 10例标本均可见小梁网梁结构,其中4例变形,3例有激光小梁成形术史。

核心结论

  • KDB小梁切开术获取的组织中小梁网含量高,标本具有足够的解剖保留可用于组织学研究,可能为研究开角型青光眼小梁网功能障碍提供新方法。

主要发现

  • 患者平均年龄74.2±6.7岁。
  • 10例标本均识别出小梁网梁结构,其中4例变形,变形的4例中3例有激光小梁成形术史。
  • 胶原IV染色在10/10例标本中阳性,覆盖小梁网梁;弹性蛋白在8/10例标本中沿小梁网梁存在。
  • 术后所有病例眼压和青光眼药物数量均显著下降(P<.0001,P=.035)。

关键数值与推荐

  • KDB小梁切开术获取标本中小梁网组织获取率为71%,传统外路小梁切除术报道的获取率为20%。

临床怎么用

  • KDB小梁切开术获取的小梁网标本可用于组织学研究,可能为研究开角型青光眼小梁网功能障碍提供新方法。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To determine whether there are identifiable, reproducible findings in the trabecular meshwork (TM) of patients with primary open-angle glaucoma (POAG) who underwent Kahook Dual Blade (KDB) goniotomy. DESIGN: Noncomparative retrospective case series. METHODS: Tertiary academic referral center, Veterans Affairs Medical Center. Thirteen patients (14 eyes) with POAG (100%) were treated with KDB goniotomy from May to December 2017. Isolated TM tissue was collected from 9 patients (10 eyes) and submitted for histologic analysis. Hematoxylin-eosin, periodic acid-Schiff, and elastin Van Gieson stains were completed, in addition to immunohistochemistry for collagen IV. RESULTS: Mean age of patients was 74.2 ± 6.7 years. Trabecular beams were identified in all 10 specimens, although distorted in 4 samples, of which 3 had a history of laser trabeculoplasty. Collagen IV staining was present in 10 of 10 samples, coating the trabecular beams. Elastin was present in 8 of 10 samples along the trabecular beams. Intraocular pressure and number of glaucoma medications decreased significantly in all cases postoperatively (P < .0001, P = .035, respectively). CONCLUSIONS: This pilot study demonstrates that tissue obtained during KDB goniotomy has a high yield of containing TM compared to reported yield of TM in specimens collected from traditional ab externo trabeculectomy (71% vs 20%, respectively). These goniotomy specimens possess sufficient anatomic preservation to be studied histologically. Trabecular meshwork obtained with this procedure may provide a novel modality to study TM dysfunction in open-angle glaucomas.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Swaminathan SS, Monsalve P, Zhou XY, et al. Histologic Analysis of Trabecular Meshwork Obtained From Kahook Dual Blade Goniotomy. Am J Ophthalmol. 2018. PMID: 29883587. doi:10.1016/j.ajo.2018.05.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。