文献速递眼底病与葡萄膜炎

扫频源OCT血管成像在脉络膜黑色素瘤中的应用:22例连续病例分析

SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IN CHOROIDAL MELANOMA: An Analysis of 22 Consecutive Cases.
PubMed 文献 · Retina · 2019-01-01

研究对22例脉络膜黑色素瘤患者行SS-OCT-A检查,评估其显示肿瘤内在血管的能力。结果显示SS-OCT-A在全部病例中检测到肿瘤微血管,其中自动脉络膜分割识别14眼(64%),自动全眼分割识别16眼(73%),手动调整分割线后识别22眼(100%)。

要点

  • SS-OCT-A在全部22眼中显示脉络膜黑色素瘤内在微血管。
  • 自动脉络膜分割识别14眼(64%),自动全眼分割识别16眼(73%),手动调整后识别22眼(100%)。
  • 吲哚菁绿血管造影在20例中显示肿瘤内在微血管20例(100%),荧光素血管造影仅4例(20%)。

核心结论

  • SS-OCT-A是评估脉络膜黑色素瘤患者的有效成像技术,在本系列中无论肿瘤大小、位置及既往治疗史,均能显示肿瘤内在微血管。

研究设计与样本

  • 连续病例系列,纳入22例(22眼)诊断为脉络膜黑色素瘤的患者,其中11例(50%)为未治疗病例。
  • 所有患者接受完整眼科评估,包括最佳矫正视力、彩色眼底照相、B超、荧光素血管造影、吲哚菁绿血管造影及SS-OCT-A(PLEX Elite 9000)。

主要发现

  • 肿瘤基底平均10.3 mm(范围5-15 mm),厚度平均4.3 mm(范围1.5-8.9 mm)。
  • 13眼(59%)记录到渗出性视网膜脱离。
  • 荧光素血管造影在20例中显示肿瘤内在微血管4例(20%),吲哚菁绿血管造影在20例中显示20例(100%)。
  • SS-OCT-A在22眼中均检测到微血管:自动脉络膜分割识别14眼(64%),自动全眼分割识别16眼(73%),手动调整分割线后识别22眼(100%)。

临床怎么用

  • SS-OCT-A可用于评估脉络膜黑色素瘤的内在微血管,手动调整分割线可提高微血管识别率。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To describe the imaging features of choroidal melanoma using swept-source optical coherence tomography angiography (SS-OCT-A) and to evaluate its ability to display tumor intrinsic vasculature. METHODS: Consecutive patients diagnosed with choroidal melanoma underwent a complete ophthalmic evaluation, including best-corrected visual acuity, color fundus photography, B-scan ultrasound, fluorescein angiography, indocyanine green angiography, and SS-OCT-A (PLEX Elite 9000; Carl Zeiss Meditec, Inc, Dublin, CA). RESULTS: Twenty-two eyes of 22 consecutive patients were included in the study; 11 cases (50%) were treatment naive. Three lesions (14%) were located at the macula, 14 (63%) between the macula and equator, and 5 (23%) between the equator and the ora serrata. The mean tumor base and thickness were, respectively, 10.3 mm (range 5-15 mm) and 4.3 mm (range 1.5-8.9 mm). Seventeen lesions (77%) were dome shaped, whereas 5 (23%) had a mushroom configuration. Thirteen lesions (59%) were pigmented, 5 (23%) partially pigmented, and 4 (18%) amelanotic. An exudative retinal detachment was documented in 13 eyes (59%). Fluorescein angiography and indocyanine green angiography were performed in 20 patients and disclosed intrinsic microvasculature of the tumor, respectively, in 4 (20%) and 20 (100%) cases. Swept-source optical coherence tomography angiography was performed in 22 eyes and detected microvasculature of choroidal melanoma in all cases. Specifically, intrinsic vasculature could be recognized in 14 eyes (64%) using the automated choroid segmentation, 16 eyes (73%) using the automated whole eye segmentation, and in 22 eyes (100%) with fine manual adjustments of segmentation lines. CONCLUSION: Swept-source optical coherence tomography angiography represents a valid imaging technique to evaluate patients affected by choroidal melanomas. In our series, SS-OCT-A disclosed the intrinsic microvasculature of the tumor in all cases despite their size, location, and history of previous treatments.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Pellegrini M, Corvi F, Invernizzi A, et al. SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IN CHOROIDAL MELANOMA: An Analysis of 22 Consecutive Cases. Retina. 2019. PMID: 29863536. doi:10.1097/IAE.0000000000002205