PubMed 文献 · Br J Ophthalmol · 2018-04-29

该研究为观察性横断面研究的回顾性分析,纳入25例早期至中期年龄相关性黄斑变性(AMD)患者的25只眼,使用偏振敏感光学相干断层扫描(OCT)评估5933个玻璃膜疣。结果显示41.3%的玻璃膜疣上方RPE完整,28.1%RPE不规则但连续,30.6%RPE信号不连续;RPE改变程度与玻璃膜疣形状、内部反射率、均匀性及直径显著相关,较大玻璃膜疣出现RPE不连续的概率更高(OR 3.2,p<0.001)。

要点

  • 偏振敏感OCT可显示玻璃膜疣特征与上方RPE完整性的相关性。
  • 5933个玻璃膜疣中30.6%上方RPE信号不连续。
  • 玻璃膜疣直径与构型与RPE丢失显著相关(OR 3.2,p<0.001)。

核心结论

  • 偏振敏感OCT显示特定玻璃膜疣特征与上方RPE层完整性相关,玻璃膜疣直径和构型与RPE丢失显著相关。

研究设计与样本

  • 回顾性观察性横断面研究,纳入25例早期至中期AMD患者的25只眼,使用偏振敏感OCT黄斑体积扫描并手动分级。

主要发现

  • 共评估5933个玻璃膜疣及其相邻RPE和光感受器层,41.3%的玻璃膜疣上方RPE完整,28.1%RPE层不规则但连续,30.6%RPE层信号不连续。
  • RPE改变程度与玻璃膜疣形状(p<0.001)、内部反射率(p<0.001)、均匀性(p<0.001)及直径显著相关,较大玻璃膜疣出现RPE不连续的概率更高(OR 3.2,p<0.001)。
  • 显示上方焦点或光感受器层改变的玻璃膜疣数量太少无法得出结论,但若存在则呈现RPE改变的倾向。

关键数值与推荐

  • RPE改变与玻璃膜疣形状、内部反射率、均匀性及直径相关(p<0.001)。
  • 较大玻璃膜疣出现RPE不连续的OR为3.2(p<0.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the impact of drusen size and structure on retinal pigment epithelium (RPE) and photoreceptor layers in eyes with early to intermediate age-related macular degeneration (AMD) using polarisation-sensitive optical coherence tomography (OCT). DESIGN: Retrospective investigation of an observational cross-sectional study. PARTICIPANTS: Patients with early to intermediate AMD. METHODS: Twenty-five eyes of 25 patients with drusen were imaged with polarisation-sensitive OCT using macular volume scans. Each scan was manually graded for six distinct drusen characteristics and the integrity of both the overlying RPE and photoreceptor layer. The central scan of each single druse, as well as its diameter and location, were selected for statistical calculations. RESULTS: A total number of 5933 individual drusen including their adjacent RPE and photoreceptor layer were evaluated. 41.3% of all drusen demonstrated an intact overlying RPE; in 28.1% the RPE layer was irregular, but continuous. In 30.6%, the RPE layer signal was discontinuous above the area of drusen. The level of RPE alteration was significantly related to shape (p<0.001), internal reflectivity (p<0.001) and homogeneity (p<0.001) of the drusen and their diameter, with a higher probability for larger drusen to have a discontinuous RPE (OR 3.2, p<0.001). The number of drusen showing overlying foci or an altered photoreceptor layer was too small to be conclusive, but showed a trend towards an altered RPE if present. CONCLUSIONS: Polarisation-sensitive OCT reveals a correlation between specific drusen characteristics and the integrity of the overlying RPE layer. Drusen diameter and configuration were significantly associated with RPE loss.