文献速递眼底病与葡萄膜炎

自动量化中心凹无血管区指标用于糖尿病视网膜病变诊断的评估

Evaluation of Automatically Quantified Foveal Avascular Zone Metrics for Diagnosis of Diabetic Retinopathy Using Optical Coherence Tomography Angiography.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2018-01-01

本研究开发基于广义梯度矢量流(GGVF)蛇形模型的自动算法,在光学相干断层扫描血管成像(OCTA)上量化中心凹无血管区(FAZ),并与黄斑外无血管面积(EAA)比较诊断糖尿病视网膜病变(DR)及关联最佳矫正视力(BCVA)的性能;纳入66只糖尿病眼和19只健康对照眼,结果显示自动与手动FAZ分割一致性Jaccard指数>0.82,EAA在区分各DR严重程度与健康对照时敏感性最高,作者认为EAA可能是更好的DR生物标志物。

要点

  • 自动FAZ检测在所有DR严重程度眼中重复性优秀,与手动分割一致性Jaccard指数>0.82。
  • 结合FAZ大小与形状不规则性的指标与临床DR分级及BCVA相关性最强。
  • 在所有测试的OCTA指标中,EAA区分无临床视网膜病变、轻中度NPDR、重度NPDR至增殖期DR与健康对照的敏感性最高。

核心结论

  • 本研究的GGVF蛇形算法可准确可靠地检测FAZ,适用于所有DR严重程度的OCTA数据,并可能用于获取糖尿病患者的黄斑缺血临床有用信息。
  • 虽然FAZ指标可提供黄斑缺血及可能的视力潜力信息,但EAA测量可能是更好的DR生物标志物。

研究设计与样本

  • 研究纳入66只糖尿病眼(来自66例糖尿病患者,涵盖不同DR严重程度)和19只健康对照眼(来自19例健康参与者),获取3×3-mm黄斑OCTA扫描。
  • 采用基于广义梯度矢量流(GGVF)蛇形模型的自动算法检测FAZ,计算FAZ大小和形状不规则性指标。
  • 将自动FAZ分割与手动勾画比较,并测试FAZ指标的访视内重复性;评估两种传统FAZ指标、两种新型FAZ指标及EAA与DR严重程度(按早期治疗糖尿病视网膜病变研究ETDRS图表确定)及BCVA的相关性。

主要发现

  • 手动与自动FAZ勾画的一致性Jaccard指数>0.82,自动FAZ检测在所有DR严重程度眼中重复性优秀。
  • 结合FAZ大小和形状不规则性的指标与临床DR分级及BCVA相关性最强。
  • 在所有测试的OCTA指标中,EAA区分无临床视网膜病变的糖尿病眼、轻中度非增殖期DR(NPDR)、重度NPDR至增殖期DR与健康对照的敏感性最高。

关键数值与推荐

  • 手动与自动FAZ勾画一致性Jaccard指数>0.82。
  • 自动FAZ检测在所有DR严重程度眼中重复性优秀。
  • EAA在所有测试的OCTA指标中区分各DR严重程度与健康对照的敏感性最高。

临床怎么用

  • 作者认为GGVF蛇形算法可准确可靠地检测FAZ,并可能用于从OCTA数据获取糖尿病患者黄斑缺血的临床有用信息。
  • 作者认为虽然FAZ指标可提供黄斑缺血及可能的视力潜力信息,但EAA测量可能是更好的DR生物标志物。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To describe an automated algorithm to quantify the foveal avascular zone (FAZ), using optical coherence tomography angiography (OCTA), and to compare its performance for diagnosis of diabetic retinopathy (DR) and association with best-corrected visual acuity (BCVA) to that of extrafoveal avascular area (EAA). METHODS: We obtained 3 × 3-mm macular OCTA scans in diabetic patients with various levels of DR and healthy controls. An algorithm based on a generalized gradient vector flow (GGVF) snake model detected the FAZ, and metrics assessing FAZ size and irregularity were calculated. We compared the automated FAZ segmentation to manual delineation and tested the within-visit repeatability of FAZ metrics. The correlations of two conventional FAZ metrics, two novel FAZ metrics, and EAA with DR severity and BCVA, as determined by Early Treatment Diabetic Retinopathy Study (ETDRS) charts, were assessed. RESULTS: Sixty-six eyes from 66 diabetic patients and 19 control eyes from 19 healthy participants were included. The agreement between manual and automated FAZ delineation had a Jaccard index > 0.82, and the repeatability of automated FAZ detection was excellent in eyes at all levels of DR severity. FAZ metrics that incorporated both FAZ size and shape irregularity had the strongest correlation with clinical DR grade and BCVA. Of all the tested OCTA metrics, EAA had the greatest sensitivity in differentiating diabetic eyes without clinical evidence of retinopathy, mild to moderate nonproliferative DR (NPDR), and severe NPDR to proliferative DR from healthy controls. CONCLUSIONS: The GGVF snake algorithm tested in this study can accurately and reliably detect the FAZ, using OCTA data at all DR severity grades, and may be used to obtain clinically useful information from OCTA data regarding macular ischemia in patients with diabetes. While FAZ metrics can provide clinically useful information regarding macular ischemia, and possibly visual acuity potential, EAA measurements may be a better biomarker for DR.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Lu Y, Simonett JM, Wang J, et al. Evaluation of Automatically Quantified Foveal Avascular Zone Metrics for Diagnosis of Diabetic Retinopathy Using Optical Coherence Tomography Angiography. Invest Ophthalmol Vis Sci. 2018. PMID: 29715365. doi:10.1167/iovs.17-23498

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。