扫描视觉诱发电位游标与光栅视力检测弱视
研究在36例成人弱视患者和36例年龄匹配正常对照中比较扫描视觉诱发电位(sVEP)游标视力、光栅视力与字母视力的关系。结果显示sVEP游标与光栅视力均与对应心理物理视力和字母视力显著相关,但游标视力更精确反映字母视力损失程度,且sVEP游标视力与字母视力呈1:1关系。
要点
- sVEP游标与光栅视力均与对应心理物理视力显著相关(P<0.001)。
- sVEP游标视力(P<0.0001)和光栅视力(P<0.01)均与字母视力显著相关。
- sVEP游标视力与字母视力呈1:1关系,比光栅视力更能反映弱视视力损失程度。
核心结论
- sVEP游标视力与字母视力呈1:1关系,而sVEP光栅视力不呈此关系,故sVEP游标视力能更好地表征弱视视力损失程度。
- 每种sVEP测量均可预测字母视力,且因无需行为反应,可能对学前及非言语患者的视功能评估有用。
研究设计与样本
- 在36例成人弱视患者和36例年龄匹配正常视力对照中测量三种视力。
- 字母视力用logMAR视力表测量,游标和光栅视力用sVEP和心理物理法对相同刺激进行估计。
- 对知觉与电生理视力测量进行回归分析。
主要发现
- sVEP游标和光栅视力与对应心理物理视力显著相关(P<0.001)。
- sVEP游标视力(P<0.0001)和光栅视力(P<0.01)均与字母视力显著相关。
- 对sVEP和心理物理测量,游标视力均比光栅视力更精确反映字母视力损失程度。
- 以不同时间频率和调制类型重复sVEP光栅视力测试,表明sVEP视力测量具有良好的可靠性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Vernier and grating acuity can be measured with swept-parameter visual evoked potentials (sVEP). However, whether sVEP Vernier and grating acuities are comparable in predicting letter acuity has not been systematically evaluated. This study evaluated the validity and reliability of sVEP Vernier and grating acuity for the detection of amblyopia in adults. METHODS: Three types of acuity were measured in 36 adults with amblyopia and 36 age-matched normal-vision controls. Letter acuity was measured with a logMAR chart. Both Vernier and grating acuity were estimated by sVEP and psychophysics for the same stimuli. Regression analyses were performed between the perceptual and electrophysiologic acuity measurements. RESULTS: SVEP Vernier and grating acuities were significantly correlated with their corresponding psychophysical acuities (P < 0.001). Both the sVEP Vernier (P < 0.0001) and grating (P < 0.01) acuities were also significantly correlated with letter acuity. However, Vernier acuity more precisely reflected the magnitude of the letter acuity loss than did grating acuity for both sVEP and psychophysical measures. Repeating sVEP grating acuity tests with different temporal frequencies and modulation types indicated good reliability of sVEP acuity measures. CONCLUSIONS: SVEP Vernier acuity has a 1:1 relationship with letter acuity, but sVEP grating acuity does not. SVEP Vernier acuity thus provides a better characterization of the magnitude of the amblyopic acuity loss than does sVEP grating acuity. Nonetheless, each of the sVEP measurements can be used to predict letter acuity and because they can be made without a behavioral response, they may be useful measures of visual function in pre- and nonverbal patients.
引用
- Hou C, Good WV, Norcia AM, et al. Detection of Amblyopia Using Sweep VEP Vernier and Grating Acuity. Invest Ophthalmol Vis Sci. 2018. PMID: 29625467. doi:10.1167/iovs.17-23021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。