深板层角膜移植术中黏弹剂与空气注射形成的分离平面不同
研究在巩膜角膜片上模拟深板层角膜移植术,比较不同深度注射黏弹剂与空气所形成大气泡的性质。黏弹剂注射多产生层内大气泡,以牵拉撕裂方式分离组织,不沿固定平面劈裂,与空气形成的1型或2型大气泡不同;术者应识别层内大气泡,避免误认为1型大气泡。
要点
- 浅层注射黏弹剂仅见层内积聚,中层注射可形成层内大气泡。
- 深层注射黏弹剂可形成1型、层内及混合大气泡,无2型大气泡。
- 黏弹剂形成的大气泡不沿固定平面劈裂,术中OCT有助识别层内大气泡。
核心结论
- 黏弹剂与空气注射所形成的大气泡可以不同,黏弹剂倾向于在注射部位发生组织牵拉撕裂,不似空气沿固定平面劈裂,术者不应将层内大气泡误认为1型大气泡。
研究设计与样本
- 在巩膜角膜片(n=32)中于浅层、中层和深层行层内注射1.2%和0.6%透明质酸钠0.1 mL与0.3 mL以模拟深板层角膜移植术,注射后针头在位行OCT检查,并对样本切片行组织学检查,另设12例空气注射对照。
主要发现
- 浅层注射(n=8)仅见黏弹剂层内积聚;中层注射(n=10)见黏弹剂层内积聚(n=6)和层内大气泡(n=4),泡壁含多少不一的基质组织,未见1型、2型或混合大气泡。
- 深层注射(n=14)获得1型大气泡(n=4)、层内大气泡(n=4)和混合大气泡(n=6)。
- 两种浓度黏弹剂的结果无差异;空气注射(n=12)获得1型大气泡10例、2型大气泡1例、混合大气泡1例,未见层内大气泡。
临床怎么用
- 术者应知悉黏弹剂分离可形成层内大气泡,不应将其与1型大气泡混淆;术中OCT应有助于识别层内大气泡。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: To investigate and define the nature of big bubbles (BB) formed by injection of viscoelastic in deep anterior lamellar keratoplasty. METHODS: Intrastromal injections of 0.1 and 0.3 mL of sodium hyaluronate 1.2% and 0.6% were made into sclera-corneal discs (n = 32) at superficial (anterior-third), midstromal (middle-third) and deep (posterior-third) levels to simulate deep anterior lamellar keratoplasty. Postinjection optical coherence tomograms (OCT) were obtained with the needle in situ. The samples were sectioned and examined histologically. Twelve control samples were injected with air. RESULTS: With superficial injections (n=8) only intrastromal accumulation of viscoelastic was noted. With midstromal injections (n=10) intrastromal accumulation of viscoelastic (n=6) and intrastromal big bubbles (IBB) (n=4) with substantial and variable stromal tissue in the walls were noted. No type 1, type 2 or mixed BB were noted. With deep injections (n=14), type 1 BB (n=4), IBB (n=4) and mixed BB (n=6) were obtained.There was no difference in the results with the two different concentrations of viscoelastic used. With air injection (n=12), 10 type 1 and 1 type 2 BB and 1 mixed BB were obtained. No IBB was noted. CONCLUSIONS: BB obtained by injection of viscoelastic and air can be different. The former tends to occur at the site of injection, especially with midstromal injections, takes the form of tissue separation by stretch and tearing and does not cleave in a consistent plane like air. Surgeons should be aware of IBB created by viscodissection and not confuse it for a type1 BB. Intraoperative OCT should help identify IBB.
引用
- Ross AR, Said DG, El-Amin A, et al. Deep anterior lamellar keratoplasty: dissection plane with viscoelastic and air can be different. Br J Ophthalmol. 2018. PMID: 29615397. doi:10.1136/bjophthalmol-2017-311349
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。