文献速递小儿眼科与斜弱视角膜与眼表疾病

儿童无晶状体眼的接触镜矫正:美国眼科学会报告

Contact Lens Correction of Aphakia in Children: A Report by the American Academy of Ophthalmology.
PubMed 文献 · Ophthalmology · 2018-04-07

该报告由美国眼科学会采用文献综述与专家小组评级方法,检索PubMed、Cochrane图书馆和ClinicalTrials.gov,纳入10篇文章(4项Ⅱ级、6项Ⅲ级证据)。硅弹性体(SE)镜与硬性透气性(RGP)镜均对儿童无晶状体眼有效,但现有数据不足以比较两者视力结局;SE镜可过夜配戴但不良事件更多,RGP镜需每晚取出且需更定制化配适但不良事件较少。

要点

  • SE镜与RGP镜均对儿童无晶状体眼有效,但证据有限。
  • 现有数据不足以比较SE镜与RGP镜的视力结局。
  • SE镜不良事件多于RGP镜;唯一直接比较的研究中RGP镜更换率约高50%。

核心结论

  • 文献证据有限;硅弹性体镜与硬性透气性镜均被证实对儿童无晶状体眼有效。
  • 硅弹性体镜更易配适且可过夜配戴;硬性透气性镜须每晚取出、需更定制化配适,但不良事件较少。
  • practitioner选择镜片类型应基于每位患者的特定需求。

研究设计与样本

  • 美国眼科学会报告,采用文献综述与专家小组评级方法。
  • 检索于2018年1月在PubMed、Cochrane图书馆和ClinicalTrials.gov进行,无日期或语言限制。
  • 合并检索共获167条引文,其中27篇全文审阅,最终10篇文章纳入评估并由小组方法学家评定证据等级。
  • 纳入研究包括4项Ⅱ级研究和6项Ⅲ级研究。

主要发现

  • 现有数据不足以比较使用硅弹性体镜与硬性透气性镜治疗眼的视力结局。
  • 硅弹性体镜可过夜配戴,但不良事件多于硬性透气性镜。
  • 硅弹性体镜相关不良事件包括微生物性角膜炎、角膜浸润、角膜水肿、角膜瘢痕、镜片粘附角膜、浅层点状角膜炎、眼睑肿胀和结膜充血。
  • 在唯一直接比较硅弹性体镜与硬性透气性镜的研究中,硬性透气性镜的镜片更换率约高50%。

关键数值与推荐

  • 硅弹性体镜可过夜配戴,但不良事件多于硬性透气性镜。
  • 硬性透气性镜须每晚取出并需更定制化配适,但不良事件较少。
  • 唯一直接比较研究中硬性透气性镜更换率约高50%。

临床怎么用

  • 作者结论认为硅弹性体镜与硬性透气性镜均对儿童无晶状体眼有效。
  • 作者指出硅弹性体镜更易配适且可过夜配戴,硬性透气性镜须每晚取出且需更定制化配适但不良事件较少。
  • 作者建议 practitioner 选择镜片类型应基于每位患者的特定需求。

局限性

  • 文献证据有限。
  • 现有数据不足以比较硅弹性体镜与硬性透气性镜的视力结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To review the published literature to assess the visual outcomes and adverse events associated with the 2 most commonly used contact lenses for treating aphakia in children: silicone elastomer (SE) and rigid gas permeable (RGP). METHODS: Literature searches were last conducted in January 2018 in the PubMed, Cochrane Library, and ClinicalTrials.gov databases with no date or language restrictions. These combined searches yielded 167 citations, 27 of which were reviewed in full text. Of these, 10 articles were deemed appropriate for inclusion in this assessment and subsequently assigned a level of evidence rating by the panel methodologist. RESULTS: The literature search identified 4 level II studies and 6 level III studies. There were insufficient data to compare visual outcomes for eyes treated using SE lenses versus RGP lenses. Silicone elastomer lenses have the advantage that they can be worn on an extended-wear basis, but they were associated with more adverse events than RGP lenses. These adverse events included microbial keratitis, corneal infiltrates, corneal edema, corneal scars, lenses adhering to the cornea, superficial punctate keratopathy, lid swelling, and conjunctival hyperemia. The lens replacement rate was approximately 50% higher for RGP lenses in the only study that directly compared SE and RGP lenses. CONCLUSIONS: Limited evidence was found in the literature on this topic. Silicone elastomer and RGP contact lenses were found to be effective for treating aphakia in children. Silicone elastomer lenses are easier to fit and may be worn on an extended-wear basis. Rigid gas permeable lenses must be removed every night and require a more customized fit, but they are associated with fewer adverse events. The choice of which lens a practitioner prescribes should be based on the particular needs of each patient.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Lambert SR, Kraker RT, Pineles SL, et al. Contact Lens Correction of Aphakia in Children: A Report by the American Academy of Ophthalmology. Ophthalmology. 2018. PMID: 29631901. doi:10.1016/j.ophtha.2018.03.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。