文献速递白内障与屈光手术

白内障术后植入节段性折射多焦人工晶状体的视觉结局

Visual Outcomes After Implantation of a Segmental Refractive Multifocal Intraocular Lens Following Cataract Surgery.
PubMed 文献 · Am J Ophthalmol · 2018-04-21

前瞻性非随机非对照病例系列纳入50眼(25例)双眼白内障患者,评估优化景深的节段性折射多焦人工晶状体术后3个月视力等指标。结果显示各距离视力均<0.20 logMAR,中距离视力与景深良好,阅读能力、对比敏感度与脱镜率高。

要点

  • 术后3个月裸眼视力在4米、80厘米、40厘米分别为0.05、0.18、0.16 logMAR。
  • 离焦曲线显示单眼与双眼视力在0.00至-2.00 D范围平坦。
  • 阅读 acuity 0.100 logRAD,阅读速度94词/分钟,脱镜率高。

核心结论

  • 该节段性多焦人工晶状体在各距离提供良好视力(<0.20 logMAR),尤其提供良好的中距离视力与景深。
  • 该晶状体显示良好的阅读能力、光学质量和对比敏感度以及高脱镜率。

研究设计与样本

  • 前瞻性、非随机、非对照病例系列,共50眼(25例患者),地点为德国法兰克福歌德大学眼科。
  • 纳入标准为双眼白内障、年龄>45岁、术后角膜散光≤0.75屈光度、中间视觉瞳孔大小3-6毫米、中心移位<1毫米(Pentacam)。
  • 排除标准为眼部手术史、弱视或预计术后矫正远视力>0.3 logMAR。
  • 术后3个月评估4米、80厘米、40厘米的裸眼与矫正视力、对比敏感度、阅读能力、离焦曲线及光学质量与脱镜问卷。

主要发现

  • 裸眼视力:4米0.05 ± 0.122 logMAR,80厘米0.18 ± 0.164 logMAR,40厘米0.16 ± 0.140 logMAR。
  • 离焦曲线测试显示单眼与双眼视力在0.00至-2.00 D范围平坦,分别为-0.03至0.11 logMAR和-0.05至0.05 logMAR。
  • 中位对比敏感度在明视与中间视觉条件下、无眩光与有眩光时分别为1.81 logCS、1.65 logCS、1.52 logCS和1.14 logCS。
  • 40厘米阅读速度显示阅读视力0.100 logRAD,速度94词/分钟。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate visual outcomes, with particular attention to intermediate visual acuity (VA), of a segmental refractive multifocal intraocular lens (IOL) with optimized depth of focus (DoF). DESIGN: Prospective, nonrandomized, noncomparative case series. METHODS: Setting: Department of Ophthalmology, Goethe University, Frankfurt/Germany. Patient or Study Population: Fifty eyes (25 patients) were included. Inclusion criteria were bilateral cataract, age > 45 years, corneal astigmatism ≤ 0.75 diopter (D) postoperatively, pupil size 3-6 mm (mesopic), and center shift < 1 mm (Pentacam). Exclusion criteria were ocular surgeries, amblyopia, or potential postoperative distance-corrected VA (DCVA) > 0.3 logMAR. Intervention or Observation: Uncorrected (UCVA) and DCVA in 4 m, 80 cm, 40 cm; contrast sensitivity (CS); reading skills; defocus curve; and questionnaire on optical quality (OQ) and spectacle independence were assessed after 3 months. MAIN OUTCOME MEASURES: UCVA and DCVA in 4 m, 80 cm, 40 cm; defocus curve. RESULTS: UCVA was 0.05 ± 0.122 logMAR at 4 m, 0.18 ± 0.164 logMAR at 80 cm, and 0.16 ± 0.140 logMAR at 40 cm. Defocus curve testing showed, respectively, a flat monocular and binocular VA range from 0.00 to -2.00 D (-0.03 to 0.11 logMAR, -0.05 to 0.05 logMAR). Median CS under photopic and mesopic conditions without and with glare was 1.81 logCS, 1.65 logCS, 1.52 logCS, and 1.14 logCS, respectively. Reading speed at 40 cm showed a reading acuity of 0.100 logRAD with 94 words/minute. CONCLUSION: This segmental multifocal IOL provides good VA at all distances (<0.20 logMAR), particularly providing good intermediate visual acuity and DoF. It showed good reading skills, OQ, and CS and high spectacle independence.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Kohnen T, Hemkeppler E, Herzog M, et al. Visual Outcomes After Implantation of a Segmental Refractive Multifocal Intraocular Lens Following Cataract Surgery. Am J Ophthalmol. 2018. PMID: 29684328. doi:10.1016/j.ajo.2018.04.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。