使用光学相干断层扫描进行宽范围角膜上皮映射
本研究使用新型商用算法的SD-OCT对220例正常眼进行直径9 mm的角膜上皮厚度映射,并评估年龄、性别和眼轴的影响,另在50例中测量重复性。结果显示除鼻侧外中央上皮厚于周边,上方象限最薄、下方最厚,男性除上方外侧外各部位上皮更厚,三个区域与年龄弱相关,与眼轴无显著关系,重复性良好至优秀。
要点
- 除鼻侧(P=0.124)外,中央角膜上皮厚于周边各区域。
- 上方象限上皮最薄,下方象限最厚。
- 男性除上方外侧(P=0.123)外各部位上皮均较厚,三个区域与年龄弱相关,与眼轴无显著关系。
核心结论
- 本研究在健康正常眼中使用新型算法进行宽直径角膜上皮映射,可作为未来研究的参考。
研究设计与样本
- 使用SD-OCT机器及新发布的商用算法计算220例个体的上皮厚度,纳入屈光误差在+5至-6屈光度(D)之间的正常眼,排除眼压>22 mm Hg、白内障史、既往眼部手术或疾病及角膜病变者,另排除有全身疾病证据或妊娠者;重复性在50例个体中测量。
主要发现
- 除鼻侧(P=0.124)外,中央角膜上皮厚度大于周边所有区域。
- 上方象限最薄,下方象限最厚。
- 男性除上方外侧区域(P=0.123)外,所有位置上皮均较厚。
- 三个区域与年龄呈弱相关:上方外侧(P=0.039,R=-0.152)、颞侧外侧(P=0.042,R=-0.150)和上方颞侧外侧(P=0.011,R=-0.187)。
- 与眼轴长度无显著关系。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To map the corneal epithelium using a map measuring 9 mm in diameter and view the effects of age, sex, and axial length. Additionally, we wanted to demonstrate the reproducibility of this technique. METHODS: We calculated the epithelial thickness in 220 individuals using an SD-OCT machine with the newly released commercially available algorithm. We included normal eyes with refractive errors between +5 and -6 diopters (D). We excluded patients with an intraocular pressure of >22 mm Hg, history of cataract, previous ocular surgery, or disease and those with corneal pathology. Additionally, we excluded patients with evidence of systemic disease or pregnancy. Lastly, reproducibility was measured in 50 individuals. RESULTS: We found the center of the corneal epithelium to be thicker than the peripheral in all zones except the nasal (P = 0.124). The superior quadrant was found to be the thinnest while the inferior was the thickest. Males had a thicker epithelium in all locations except the superior outer section (P = 0.123). Three zones had a weak correlation with age: outer superior (P = 0.039, R = -0.152); outer temporal (P = 0.042, R = -0.150); and outer superior temporal (P = 0.011, R = -0.187). There was no significant relationship with the axial length. We found good to excellent reproducibility when using this technique in the central as well as the peripheral cornea. CONCLUSIONS: We provide a comprehensive study in healthy, normal eyes using a novel algorithm to map the corneal epithelium with a wide diameter. This study can be used as a reference for future research.
引用
- Hashmani N, Hashmani S, Saad CM, et al. Wide Corneal Epithelial Mapping Using an Optical Coherence Tomography. Invest Ophthalmol Vis Sci. 2018. PMID: 29625491. doi:10.1167/iovs.17-23717