新生血管性年龄相关性黄斑变性中包括视网膜下高反射物质在内的病灶自动分割
该研究构建了基于卷积神经网络(CNN)的自动分割算法,使用93例新生血管性年龄相关性黄斑变性(nAMD)患者的930张B扫描光谱域光学相干断层扫描(SD-OCT)图像进行训练与验证。结果显示,该网络对眼内液(IRF)、视网膜下液(SRF)、色素上皮脱离(PED)和视网膜下高反射物质(SHRM)的分割与检测与临床医生具有良好一致性。
要点
- CNN网络对IRF、SRF、SHRM和PED分割的Dice系数分别为0.78、0.82、0.75和0.80。
- 所有病灶检测均获得高阳性预测值(范围0.94-0.99)和高敏感性(范围0.97-0.99)。
- CNN网络可为临床医生提供nAMD病灶的定量数据。
核心结论
- 基于CNN的网络通过自动分割和检测包括IRF、SRF、PED和SHRM在内的病理病灶,为临床医生提供nAMD的定量数据。
研究设计与样本
- 诊断工具的信度与效度分析,构建了包含93例nAMD患者93只眼的930张B扫描数据集。
- 使用来自550张B扫描的11550张增强图像训练CNN深度神经网络。
- 使用包含140张B扫描的验证集和240张B扫描的测试集评估训练后网络的性能。
主要发现
- 训练网络与临床医生在病灶分割和检测方面均观察到良好一致性。
- IRF、SRF、SHRM和PED分割的Dice系数分别为0.78、0.82、0.75和0.80。
- IRF、SRF、SHRM和PED的阳性预测值分别为0.79、0.80、0.75和0.80。
- IRF、SRF、SHRM和PED的敏感性分别为0.77、0.84、0.73和0.81。
- IRF、SRF、SHRM和PED的相对面积差分别为-4.32%、-10.29%、4.13%和0.34%,组内相关系数分别为0.98、0.98、0.97和0.98。
关键数值与推荐
- 所有病灶检测均具有高阳性预测值(范围0.94-0.99)和高敏感性(范围0.97-0.99)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate an automated segmentation algorithm with a convolutional neural network (CNN) to quantify and detect intraretinal fluid (IRF), subretinal fluid (SRF), pigment epithelial detachment (PED), and subretinal hyperreflective material (SHRM) through analyses of spectral-domain optical coherence tomography (SD-OCT) images from patients with neovascular age-related macular degeneration (nAMD). DESIGN: Reliability and validity analysis of a diagnostic tool. METHODS: We constructed a dataset including 930 B-scans from 93 eyes of 93 patients with nAMD. A CNN-based deep neural network was trained using 11 550 augmented images derived from 550 B-scans. The performance of the trained network was evaluated using a validation set including 140 B-scans and a test set of 240 B-scans. The Dice coefficient, positive predictive value (PPV), sensitivity, relative area difference (RAD), and intraclass correlation coefficient (ICC) were used to evaluate segmentation and detection performance. RESULTS: Good agreement was observed for both segmentation and detection of lesions between the trained network and clinicians. The Dice coefficients for segmentation of IRF, SRF, SHRM, and PED were 0.78, 0.82, 0.75, and 0.80, respectively; the PPVs were 0.79, 0.80, 0.75, and 0.80, respectively; and the sensitivities were 0.77, 0.84, 0.73, and 0.81, respectively. The RADs were -4.32%, -10.29%, 4.13%, and 0.34%, respectively, and the ICCs were 0.98, 0.98, 0.97, and 0.98, respectively. All lesions were detected with high PPVs (range 0.94-0.99) and sensitivities (range 0.97-0.99). CONCLUSIONS: A CNN-based network provides clinicians with quantitative data regarding nAMD through automatic segmentation and detection of pathologic lesions, including IRF, SRF, PED, and SHRM.
引用
- Lee H, Kang KE, Chung H, et al. Automated Segmentation of Lesions Including Subretinal Hyperreflective Material in Neovascular Age-related Macular Degeneration. Am J Ophthalmol. 2018. PMID: 29655643. doi:10.1016/j.ajo.2018.04.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。