1273只连续眼植入两种环曲面人工晶状体旋转稳定性的比较

Comparison of the Rotational Stability of Two Toric Intraocular Lenses in 1273 Consecutive Eyes.
PubMed 文献 · Ophthalmology · 2018-03-12

该回顾性队列研究在单一私立诊所纳入18个月内接受白内障手术并植入Acrysof(626眼)或Tecnis(647眼)环曲面人工晶状体的连续患者,比较术后旋转稳定性。Acrysof组术后旋转≤5度的眼比例显著高于Tecnis组(91.9% vs 81.8%,P<0.0001),平均旋转度数更低,Tecnis更倾向逆时针旋转,但需再次手术复位比例无显著差异(3.1% vs 1.6%,P=0.10)。

要点

  • Acrysof组术后旋转≤5度眼比例91.9%,显著高于Tecnis组81.8%(P<0.0001)。
  • Acrysof组平均旋转2.72度,低于Tecnis组3.79度(P<0.05)。
  • Tecnis组需复位比例3.1% vs Acrysof组1.6%,未达统计学显著(P=0.10)。

核心结论

  • Acrysof环曲面人工晶状体较Tecnis环曲面人工晶状体表现出显著更高的旋转稳定性。

研究设计与样本

  • 回顾性队列研究,在单一私立诊所进行,纳入2015年4月至2016年9月18个月期间所有植入Acrysof(n=626)或Tecnis(n=647)环曲面人工晶状体的患者,仅排除无法使用数字标记系统手术者。
  • 所有患者在同一手术中心以相似技术行白内障手术,使用基于角膜缘血管配准的数字标记系统记录术毕晶状体轴位,术后当日或次晨散瞳检查比较两种晶状体模型术后旋转。
  • 主要结局指标为晶状体旋转>5度和>10度的眼百分比,次要主要结局为需返回手术室复位旋转晶状体的可能性。

主要发现

  • 首次术后检查时,Acrysof组91.9%眼旋转≤5度,Tecnis组81.8%(P<0.0001)。
  • 旋转≤10度者Acrysof组97.8% vs Tecnis组93.2%(P=0.0002),≤15度者98.6% vs 96.4%(P=0.02)。
  • 平均旋转度数Acrysof组2.72度(95%CI 2.35-3.08度)vs Tecnis组3.79度(95%CI 3.36-4.22度),P<0.05。
  • Tecnis环曲面人工晶状体表现出强烈的逆时针旋转倾向,而Acrysof无此倾向。
  • 需复位者Tecnis组3.1% vs Acrysof组1.6%,未达统计学显著(P=0.10);两组屈光结果相似。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the rotational stability of the 2 most commonly used toric intraocular lenses (TIOLs). DESIGN: Retrospective cohort study in a single private practice. SUBJECTS: The study included all patients receiving an Acrysof (n = 626) or Tecnis TIOL (n = 647) over an 18-month period from April 2015 to September 2016. Patients were only excluded if their surgery could not be performed using a digital marking system. METHODS: All patients had cataract surgery performed in the same surgical center with a similar technique. A digital marking system with limbal vessel registration was used to record the axis of the TIOL at the conclusion of surgery. A dilated examination was performed either later on the day of surgery or the next morning, and the postoperative rotation of the 2 TIOL models was compared. Patients who required a return to the operating room for TIOL repositioning were examined to determine risk factors for reoperation and subsequent outcomes. MAIN OUTCOME MEASURES: The primary outcome measure was the percentage of eyes with TIOL rotation >5 and >10 degrees. The second main outcome was likelihood of requiring return to the operating room to reposition a rotated TIOL. RESULTS: The Acrysof TIOL was less likely to rotate postoperatively, with 91.9% of eyes rotated ≤5 degrees at the first postoperative check compared with 81.8% of Tecnis TIOL eyes (P < 0.0001). This difference persisted for rotation ≤10 degrees (97.8% Acrysof vs. 93.2% Tecnis, P = 0.0002) and ≤15 degrees (98.6% Acrysof vs. 96.4% Tecnis, P = 0.02). The mean rotation was 2.72 degrees (95% confidence interval 2.35-3.08 degrees) for Acrysof and 3.79 degrees (95% confidence interval 3.36-4.22 degrees) for Tecnis TIOLs (P < 0.05). The Tecnis TIOL showed a strong predisposition to rotate counterclockwise, unlike the Acrysof. More Tecnis TIOL patients required repositioning (3.1% vs. 1.6%), but this did not reach statistical significance (P = 0.10). Refractive outcomes were similar between the 2 groups. CONCLUSIONS: The Acrysof TIOL showed significantly greater rotational stability than the Tecnis TIOL.