文献速递青光眼

使用结合结构与功能测量的二维连续时间隐马尔可夫模型预测青光眼进展的临床性能

Clinical Prediction Performance of Glaucoma Progression Using a 2-Dimensional Continuous-Time Hidden Markov Model with Structural and Functional Measurements.
PubMed 文献 · Ophthalmology · 2018-03-20

本研究在134只眼(134例青光眼或疑似青光眼患者,平均随访4.4±1.2年)中评估二维连续时间隐马尔可夫模型(2D CT HMM)预测青光眼变化检测的性能。模型基于OCT平均环视盘视网膜神经纤维层厚度和视野指数或平均偏差训练,训练集预测准确率57.0%,验证集68.0%,预测偏差在随访中保持稳定。

要点

  • 2D CT HMM利用单次访视信息可预测至少5次后续访视的变化检测,性能相似。
  • 训练集预测准确率57.0%,验证集68.0%。
  • 预测长期变化路径的偏差在整个随访期间保持稳定。

核心结论

  • 2D CT HMM在模拟临床环境中对青光眼变化检测显示出有前景的预测性能。
  • 该模型允许仅用1次访视的信息预测至少5次后续访视,且性能相似。

研究设计与样本

  • 纵向、回顾性研究,纳入134例青光眼或疑似青光眼患者的134只眼,平均随访4.4±1.2年,平均访视次数7.1±1.8。
  • 使用OCT平均环视盘视网膜神经纤维层厚度和视野指数或平均偏差训练2D CT HMM。
  • 训练集为134只眼中的107只眼(80%),包含除最后一次访视外的所有访视;验证集为剩余27只眼,作为独立组进行二次性能测试。

主要发现

  • 基线平均年龄61.9±11.4岁,视野指数90.7±17.4,平均偏差-3.50±6.04 dB,环视盘视网膜神经纤维层厚度74.9±12.2 μm。
  • 训练集预测准确率57.0%,验证集68.0%。
  • 预测的长期检测变化路径与实际检测变化路径的偏差在整个患者随访期间保持稳定。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Previously, we introduced a state-based 2-dimensional continuous-time hidden Markov model (2D CT HMM) to model the pattern of detected glaucoma changes using structural and functional information simultaneously. The purpose of this study was to evaluate the detected glaucoma change prediction performance of the model in a real clinical setting using a retrospective longitudinal dataset. DESIGN: Longitudinal, retrospective study. PARTICIPANTS: One hundred thirty-four eyes from 134 participants diagnosed with glaucoma or as glaucoma suspects (average follow-up, 4.4±1.2 years; average number of visits, 7.1±1.8). METHODS: A 2D CT HMM model was trained using OCT (Cirrus HD-OCT; Zeiss, Dublin, CA) average circumpapillary retinal nerve fiber layer (cRNFL) thickness and visual field index (VFI) or mean deviation (MD; Humphrey Field Analyzer; Zeiss). The model was trained using a subset of the data (107 of 134 eyes [80%]) including all visits except for the last visit, which was used to test the prediction performance (training set). Additionally, the remaining 27 eyes were used for secondary performance testing as an independent group (validation set). The 2D CT HMM predicts 1 of 4 possible detected state changes based on 1 input state. MAIN OUTCOME MEASURES: Prediction accuracy was assessed as the percentage of correct prediction against the patient's actual recorded state. In addition, deviations of the predicted long-term detected change paths from the actual detected change paths were measured. RESULTS: Baseline mean ± standard deviation age was 61.9±11.4 years, VFI was 90.7±17.4, MD was -3.50±6.04 dB, and cRNFL thickness was 74.9±12.2 μm. The accuracy of detected glaucoma change prediction using the training set was comparable with the validation set (57.0% and 68.0%, respectively). Prediction deviation from the actual detected change path showed stability throughout patient follow-up. CONCLUSIONS: The 2D CT HMM demonstrated promising prediction performance in detecting glaucoma change performance in a simulated clinical setting using an independent cohort. The 2D CT HMM allows information from just 1 visit to predict at least 5 subsequent visits with similar performance.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Song Y, Ishikawa H, Wu M, et al. Clinical Prediction Performance of Glaucoma Progression Using a 2-Dimensional Continuous-Time Hidden Markov Model with Structural and Functional Measurements. Ophthalmology. 2018. PMID: 29571832. doi:10.1016/j.ophtha.2018.02.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。