文献速递青光眼神经眼科

基于个体视网膜神经纤维层厚度轮廓的视野采样

Sampling the Visual Field Based on Individual Retinal Nerve Fiber Layer Thickness Profile.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2018-01-01

研究提出一种基于个体视网膜神经纤维层(RNFL)厚度轮廓的缺陷采样法选择视野测试点,并在23例青光眼患者中与均匀采样、24-2模式、极坐标模式及简化极坐标模式比较。结果显示,在15只眼中缺陷采样法在9只眼发现更多异常位点,显著优于其他三种采样方案;8只眼无方法优于随机预期。

要点

  • 缺陷采样法结合24-2高预测值位点与基于RNFL厚度的额外位点,共52个测试点。
  • 在15只可分析眼中,缺陷采样法在9只眼识别更多异常位点,显著优于24-2、极坐标、简化极坐标和均匀采样。
  • 8只眼中无任何方法发现多于随机预期的异常点。

主要发现

  • 8只眼中无方法发现多于随机预期的异常点(超几何分布,P < 0.05)。
  • 剩余15只眼中,缺陷采样法在9只眼识别更多异常位置,显著优于24-2模式(2只眼,P < 0.001)、极坐标模式(2只眼,P < 0.001)、简化极坐标模式(2只眼,P < 0.004)和均匀采样(1只眼,P < 0.001)。

关键数值与推荐

  • 首先选择24-2模式中检测青光眼阳性预测值最高的26个视野位点,再基于RNFL厚度从2×2度网格中选择额外26个位点。
  • 使用个体化映射将视野位点与视盘周围RNFL厚度关联。

局限性

  • 8只眼中无方法发现多于随机预期的异常点,原文未进一步说明原因。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Current perimeters use fixed grid patterns. We test whether a grid based on an individual's retinal nerve fiber layer (RNFL) thickness profile would find more visual field (VF) defects. METHODS: We describe the defect-based method for choosing test locations. First, the 26 VF locations with the highest positive predictive value to detect glaucoma from the 24-2 pattern are chosen. An additional 26 locations are chosen from a 2 × 2 degree grid based on RNFL thickness. An individualized map was used to relate VF locations to peripapillary RNFL thickness. To test whether the 52 locations chosen by the defect-based method find more defects than other test grids, we collected a 386-location (2 × 2 degree grid) VF measurement on 23 glaucoma participants and classed each location in the dataset as either abnormal or normal using a suprathreshold test. Using this data, defect-based sampling was compared to: a method that sampled VF locations uniformly around the optic nerve head (ONH); the 24-2 pattern; a polar pattern; and a reduced polar pattern. The outcome measure was the number of abnormal points that were selected as test locations. RESULTS: For 8 eyes, no method found more abnormal points than would be expected by chance (hypergeometric distribution, P < 0.05). Of the remaining 15 eyes, the defect-based method identified more abnormal locations on nine eyes, which was significantly better than the other three sampling schemes (24-2: 2 eyes, P < 0.001; polar: 2 eyes, P < 0.001; reduced polar: 2 eyes, P < 0.004; and uniform: 1 eye, P < 0.001). CONCLUSIONS: Using structural information to choose locations to test in a VF for individual patients identifies more abnormal locations than using existing grid patterns and uniform sampling based on structure.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Ballae Ganeshrao S, Turpin A, McKendrick AM, et al. Sampling the Visual Field Based on Individual Retinal Nerve Fiber Layer Thickness Profile. Invest Ophthalmol Vis Sci. 2018. PMID: 29490343. doi:10.1167/iovs.17-21979

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。