文献速递角膜与眼表疾病

软性接触镜佩戴者眼表温度与泪膜稳定性的关联

Association Between Ocular Surface Temperature and Tear Film Stability in Soft Contact Lens Wearers.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2018-01-01

本研究纳入20例正常软性接触镜佩戴者的20只眼,比较四种日抛型软性接触镜佩戴前后眼表温度变化(ΔOST)与泪膜稳定性的相关性。结果显示ΔOST与无创泪膜破裂时间(NIBUT)及泪膜干涉图案(TIPCL)分级显著相关,硅水凝胶镜片delefilcon A的ΔOST显著小于水凝胶镜片。作者认为眼表温度变化可用于评估软性接触镜佩戴者的泪膜稳定性。

要点

  • ΔOST与NIBUT在无镜片及戴镜状态下均显著相关(r=0.411与r=0.642,P<0.01)。
  • 戴镜时TIPCL分级与ΔOST显著相关(r=-0.636,P<0.01)。
  • delefilcon A的ΔOST显著小于etafilcon A与polymacon(P<0.05与P<0.01)。

核心结论

  • 软性接触镜佩戴时眼表温度变化与泪膜稳定性相关,眼表温度测量可用于评估软性接触镜佩戴者的泪膜稳定性。

研究设计与样本

  • 研究纳入20例正常软性接触镜佩戴者的20只眼(20名男性,年龄24.4±4.1岁),比较四种日抛型软性接触镜(硅水凝胶delefilcon A及水凝胶etafilcon A含聚乙烯吡咯烷酮、etafilcon A、polymacon)佩戴前与佩戴15分钟后的参数。

主要发现

  • ΔOST与NIBUT在无镜片时(r=0.411,P<0.01)及戴镜时(r=0.642,P<0.01)均显著相关。
  • 戴镜时TIPCL分级与ΔOST显著相关(r=-0.636,P<0.01)。
  • delefilcon A的ΔOST显著小于etafilcon A(P<0.05)及polymacon(P<0.01)。
  • delefilcon A与含PVP的etafilcon A的NIBUT均显著小于etafilcon A(两者比较P<0.05)。
  • delefilcon A的TIPCL分级显著小于etafilcon A及polymacon(两者比较P<0.01)。

临床怎么用

  • 作者认为,眼表温度测量可用于评估软性接触镜佩戴者的泪膜稳定性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate the correlation between the changes in the ocular surface temperature (OST) and tear film stability over soft contact lenses (SCLs). METHODS: We enrolled 20 eyes of 20 normal SCL wearers (20 men; 24.4 ± 4.1 years). We used four different daily disposable SCLs: one silicone hydrogel lens (delefilcon A) and three hydrogel lenses (etafilcon A with polyvinylpyrrolidone [PVP], etafilcon A, and polymacon). OST was measured every second during 10 seconds without blinking. We defined the difference in the OST from 0 to 10 seconds as ΔOST. To evaluate tear film stability, we measured noninvasive tear break-up time (NIBUT) and tear interference patterns on the contact lenses (TIPCL) using tear film interferometry. The parameters were measured before and 15 minutes after wearing each SCL. RESULTS: ΔOST was correlated significantly with NIBUT without (r = 0.411, P < 0.01) and with SCL (r = 0.642, P < 0.01). TIPCL grade was correlated significantly with ΔOST over SCLs (r = -0.636, P < 0.01). ΔOST was significantly smaller with silicone hydrogel delefilcon A than hydrogel etafilcon A and polymacon lenses (P < 0.05 and P < 0.01, respectively). Delefilcon A and etafilcon A with PVP lenses had significantly smaller NIBUT than etafilcon A (P < 0.05 for both comparisons). TIPCL grade of delefilcon A lens was significantly smaller than those of etafilcon A and polymacon (P < 0.01 for both comparisons). CONCLUSIONS: The changes in OST over SCLs are related to tear film stability. Measurements of OST can be used to evaluate tear film stability for SCL wearers.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。