双眼眼轴长度与角膜屈光力差异对白内障术后屈光结果的预测作用
该回顾性队列研究纳入2013年9月至2015年8月在TLC(加拿大安大略省米西索加)接受双侧超声乳化术的729例患者(1458眼),比较按双眼眼轴长度差异(IALD)和双眼角膜屈光力差异(IKD)分层的术后屈光误差>0.5 D比例。结果显示IALD≥0.2 mm与术后屈光误差>0.5 D风险升高相关,IALD≥0.4 mm时70.0%在目标范围内 vs <0.4 mm时80.7%;IKD与屈光误差 largely 无关,但IKD较大与术后UCVA>0.3 logMAR风险升高相关。
要点
- IALD≥0.2 mm即与术后屈光误差>0.5 D风险升高相关(OR 1.4,95%CI 1.1-1.8)。
- IALD≥0.4 mm者70.0%在目标范围内 vs <0.4 mm者80.7%。
- IKD与屈光误差 largely 无关,但IKD较大与术后UCVA>0.3 logMAR风险升高相关。
核心结论
- 双眼眼轴长度差异小至≥0.2 mm即与术后屈光误差>0.5 D风险升高及更差UCVA相关。
- 双眼角膜屈光力差异与术后屈光误差无关,但差异≥0.4 D与更差UCVA相关。
- 作者认为这些切点应在术前规划和与患者讨论中考虑,未来需研究重复测量、辅助测量设备或区分真实差异与伪影能否减少残余屈光误差。
研究设计与样本
- 回顾性队列研究,纳入2013年9月至2015年8月在TLC(加拿大安大略省米西索加)接受双侧超声乳化术的729例患者(1458眼)。
- 采用广义估计方程计算比例、OR及95%CI以校正患者内相关性。
主要发现
- 79.1%的眼屈光误差≤0.5 D,47.0%≤0.25 D,97.2%≤1.0 D。
- IALD切点0.2 mm时屈光误差>0.5 D的OR为1.4(95%CI 1.1-1.8),0.3 mm时为1.6(95%CI 1.2-2.1),0.4 mm时为1.8(95%CI 1.3-2.5)。
- IALD≥0.4 mm者70.0%(95%CI 63.5-75.7)在目标范围内 vs <0.4 mm者80.7%(95%CI 78.4-82.9)。
- 对于给定IALD的患者,较短眼与较长眼超出目标的机会相似。
- 超出目标的眼睛<-0.5 D的可能性是>0.5 D的两倍。
关键数值与推荐
- 屈光误差>0.5 D的OR:IALD 0.2 mm为1.4(95%CI 1.1-1.8),0.3 mm为1.6(95%CI 1.2-2.1),0.4 mm为1.8(95%CI 1.3-2.5)。
- 目标范围内比例:IALD≥0.4 mm为70.0%(95%CI 63.5-75.7) vs <0.4 mm为80.7%(95%CI 78.4-82.9)。
- 术后UCVA>0.3 logMAR风险升高与较大IKD-平、陡及平均相关,IKD≥0.4 D与更差UCVA相关。
临床怎么用
- 作者认为这些切点应在术前规划和与患者讨论中考虑。
- 作者提出未来需研究重复测量、使用辅助测量设备或基于术前屈光特征区分真实差异与伪影能否减少残余屈光误差。
局限性
- 未来需研究重复测量、使用辅助测量设备或尝试基于术前屈光特征区分真实差异与伪影能否减少残余屈光误差。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To determine whether differences between eyes in axial length (AL) and corneal power (K) on optical biometry are predictive of refractive outcomes. DESIGN: Retrospective cohort study. PARTICIPANTS: A total of 729 patients (1458 eyes) who underwent bilateral phacoemulsification at TLC (Mississauga, Ontario, Canada) from September 2013 to August 2015. METHODS: We compared the proportion of patients having >0.5 diopters (D) of refractive error from target stratified by interocular axial length differences (IALDs) and interocular K differences (IKDs) between eyes as measured by optical biometry (IOL-Master, Carl Zeiss Meditec, Oberkochen, Germany). Analysis was repeated for 0.25 D or 1.0 D targets and for patients with uncorrected visual acuity (UCVA) >0.3 logarithm of the minimum angle of resolution (logMAR) postoperatively. MAIN OUTCOME MEASURES: Proportions, odds ratios (ORs), and corresponding 95% confidence intervals (CIs) were computed using generalized estimating equations to account for within-patient correlation. RESULTS: Some 79.1% of eyes were ≤0.5 D of refractive target, 47.0% were ≤0.25 D, and 97.2% were ≤1.0 D. The OR of having a refractive outcome >0.5 D from target for IALD cutoff of 0.2 mm was 1.4 (1.1-1.8), of 0.3 mm was 1.6 (1.2-2.1), and of 0.4 mm was 1.8 (1.3-2.5). This translates to 70.0% (63.5-75.7) within target for IALD of ≥0.4 mm versus 80.7% (78.4-82.9) for <0.4 mm. For a given patient with IALD, the chance of being off target was similar for the shorter and longer eye. Eyes outside of target were twice as likely to be <-0.5 D than >0.5 D. Interocular K difference was largely not associated with prediction error, yet larger IKD-flat, steep, and average were associated with increased odds of UCVA >0.3 logMAR postoperatively. CONCLUSIONS: Interocular axial length difference of as little as ≥0.2 mm is associated with a higher chance of >0.5 D of refractive error from target and worse UCVA. Interocular K difference was not associated with worse refractive error from target, although a difference of ≥0.4 D was associated with worse UCVA. These cutoffs should be considered in preoperative planning and discussion with patients. Future study is required to assess whether repeating measurements, using adjunctive measurement devices, or attempting to separate true differences from artifact based on preoperative refractive characteristics reduces residual refractive error.
引用
- Kansal V, Schlenker M, Ahmed IIK, et al. Interocular Axial Length and Corneal Power Differences as Predictors of Postoperative Refractive Outcomes after Cataract Surgery. Ophthalmology. 2018. PMID: 29459040. doi:10.1016/j.ophtha.2018.01.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。