文献速递角膜与眼表疾病

原发性后弹力层内皮角膜移植术中早期移植物脱离的相关因素

Factors Associated With Early Graft Detachment in Primary Descemet Membrane Endothelial Keratoplasty.
PubMed 文献 · Am J Ophthalmol · 2018-01-12

这项病例对照研究纳入173枚供体角膜和173只接受后弹力层内皮角膜移植术(DMEK)或DMEK联合白内障摘除及人工晶状体植入术的患眼,评估早期移植物脱离的危险因素。多因素分析显示,DMEK联合白内障摘除及人工晶状体植入术(OR=5.31,95%CI 2.03-13.86,P<.002)和术后2-3小时前房空气填充≤75%前房高度(OR=2.66,95%CI 1.12-6.34,P=.027)是术后移植物脱离的独立危险因素。作者认为,DMEK同期行白内障摘除是早期移植物脱离的危险因素,序贯手术可能优于联合手术以减少再次注气;术后早期应监测前房空气水平并维持在75%以上。

要点

  • DMEK联合白内障摘除及人工晶状体植入术是早期移植物脱离的独立危险因素(OR=5.31)。
  • 术后2-3小时前房空气填充≤75%前房高度是移植物脱离的独立危险因素(OR=2.66)。
  • 作者认为序贯手术可能优于联合手术,术后早期前房空气水平应维持在75%以上。

核心结论

  • DMEK同期行白内障摘除是早期移植物脱离的危险因素,序贯手术可能优于联合手术以减少再次注气。
  • 术后早期应监测前房空气水平并维持在75%以上。

研究设计与样本

  • 病例对照研究,纳入173枚供体角膜和173只接受DMEK或DMEK联合超声乳化及人工晶状体植入术的患眼。
  • 采用预剥离DMEK移植物经pull-through技术移植,术毕前房注入空气,仅怀疑瞳孔阻滞时于3小时后移除。
  • 所有移植物脱离病例均行再次注气,不论脱离范围,均经眼前段光学相干断层扫描记录。
  • 供体特征来自眼库数据库并与受体数据库匹配。

主要发现

  • DMEK联合白内障摘除及人工晶状体植入术是移植物脱离的独立危险因素(OR=5.31,95%CI 2.03-13.86,P<.002)。
  • 术后2-3小时前房空气填充≤75%前房高度是移植物脱离的独立危险因素(OR=2.66,95%CI 1.12-6.34,P=.027)。

关键数值与推荐

  • DMEK联合白内障摘除及人工晶状体植入术:OR=5.31,95%CI 2.03-13.86,P<.002。
  • 术后2-3小时前房空气填充≤75%前房高度:OR=2.66,95%CI 1.12-6.34,P=.027。

临床怎么用

  • 作者认为,为减少再次注气,序贯手术可能优于DMEK联合白内障摘除手术。
  • 作者建议术后早期监测前房空气水平并维持在75%以上。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the risk factors for early graft detachment in Descemet membrane endothelial keratoplasty (DMEK). DESIGN: Case-control study. METHODS: Participants: A total of 173 donor corneas and 173 eyes of the patients following DMEK or DMEK in combination with phacoemulsification and intraocular lens implantation were included. INTERVENTION: Pre-stripped DMEK grafts were transplanted using pull-through technique. At the end of surgery, the anterior chamber was filled with air, which was removed 3 hours later only if pupillary block was suspected. Rebubbling was performed in all cases with graft detachment, independently of its extension, as documented by means of anterior segment optical coherence tomography. The donor characteristics were collected from the eye bank database and matched with the recipient database. MAIN OUTCOME MEASURES: Donor and recipient characteristics affecting graft detachment using univariate and multivariate analysis. RESULTS: The combination of DMEK with cataract removal and IOL implantation (odds ratio [OR] = 5.31, 95% confidence interval [CI] 2.03-13.86, P < .002) and air fill of ≤75% of anterior chamber height at 2-3 hours postoperatively (OR = 2.66, 95% CI 1.12-6.34, P = .027) were found to be independent risk factors for postoperative graft detachment. CONCLUSIONS: Cataract removal at the time of DMEK is a risk factor for early graft detachment and therefore sequential surgery may be preferred over combined surgery in an attempt at minimizing rebubbling. Air level in the anterior chamber should be monitored and maintained above 75% in the early hours following surgery.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Leon P, Parekh M, Nahum Y, et al. Factors Associated With Early Graft Detachment in Primary Descemet Membrane Endothelial Keratoplasty. Am J Ophthalmol. 2018. PMID: 29339064. doi:10.1016/j.ajo.2017.12.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。