健康眼、高眼压症眼与青光眼眼在急性眼压升高后的活体三维筛板应变
研究比较了健康眼(20只)、高眼压型原发性开角型青光眼(POAG,20只)、原发性闭角型青光眼(PACG,16只)和高眼压症(OHT,20只)眼在急性眼压升高至约35和45 mmHg后的活体筛板三维应变。结果显示OHT眼平均筛板应变(3.96%)显著低于健康眼(6.81%,P<0.05),POAG眼平均应变高于PACG眼(4.05%),健康眼高于POAG和PACG眼,但后述差异无统计学显著性。
要点
- 高眼压症眼平均筛板应变3.96%,显著低于健康眼的6.81%(P<0.05)。
- POAG眼平均筛板应变高于PACG眼(4.05%),健康眼高于POAG和PACG眼,但差异无统计学显著性。
- POAG和OHT眼的局部筛板变形在颞下和颞侧八分区应变最低。
核心结论
- 在活体人眼可测得急性眼压升高引起的筛板应变。
- 在该研究人群中,数据提示高眼压症筛板承受的眼压诱导应变低于健康筛板。
研究设计与样本
- 研究纳入20只健康眼、20只高眼压型原发性开角型青光眼眼、16只原发性闭角型青光眼眼和20只高眼压症眼(视野正常)。
- 每只测试眼在基线眼压及使用眼压计急性升高眼压至约35 mmHg和45 mmHg后,用光学相干断层扫描(OCT)对视神经乳头各成像三次。
- 对基线和眼压升高后的OCT容积应用三维应变映射算法提取眼压诱导的三维应变,并提取八分区筛板应变以研究局部变形模式。
主要发现
- 高眼压症受试者平均筛板应变为3.96%,显著低于健康受试者的6.81%(P<0.05)。
- POAG受试者平均筛板应变高于PACG受试者的4.05%,健康受试者高于POAG和PACG受试者,但这些差异无统计学显著性。
- POAG和高眼压症受试者的局部筛板变形在颞下和颞侧八分区应变最低。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare in vivo lamina cribrosa (LC) strains (deformations) following acute IOP elevation in healthy, glaucoma, and ocular hypertensive subjects. METHODS: There were 20 healthy, 20 high-tension primary open-angle glaucoma (POAG), 16 primary angle-closure glaucoma (PACG), and 20 ocular hypertensive (OHT; with normal visual fields) eyes studied. For each test eye, the optic nerve head was imaged three times (at baseline IOP, following an acute elevation of IOP to approximately 35 then 45 mm Hg using an ophthalmodynamomter) using optical coherence tomography (OCT). A three-dimensional (3D) strain-mapping algorithm was applied to both sets of baseline and IOP-elevated OCT volumes to extract IOP-induced 3D strains. Octant-wise LC strains were also extracted to study the pattern of local deformation. RESULTS: The average LC strain in OHT subjects (3.96%) was significantly lower than that measured in healthy subjects (6.81%; P < 0.05). On average, POAG subjects experienced higher strain than the PACG subjects (4.05%), healthy subjects experienced higher strains than the POAG and PACG subjects, but these difference were not statistically significant. Local LC deformations showed lowest strain in the infero-temporal and temporal octant in the POAG and OHT subjects. CONCLUSIONS: We demonstrate measurable LC strains in vivo in humans as a response to acute IOP elevation. In this population, our data suggest that OHT LCs experience lower IOP-induced strains than healthy LCs.
引用
- Beotra MR, Wang X, Tun TA, et al. In Vivo Three-Dimensional Lamina Cribrosa Strains in Healthy, Ocular Hypertensive, and Glaucoma Eyes Following Acute Intraocular Pressure Elevation. Invest Ophthalmol Vis Sci. 2018. PMID: 29340640. doi:10.1167/iovs.17-21982
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。