SITA标准视野检查在检测青光眼进展方面优于FDT2矩阵视野检查
研究纳入120例青光眼患者,在基线和随后4年中每6个月接受一次HFA SITA标准自动视野检查和FDT2检查,采用逐点线性回归(PLR)并按三种标准判定视野进展。结果显示,无论采用哪种标准,HFA SITA标准检测到的视野进展率总体均高于FDT2(P<0.001)。
要点
- 120例青光眼患者每6个月接受HFA SITA标准与FDT2检查,持续4年。
- 采用逐点线性回归并按三种进展标准比较两种视野检查。
- 无论采用哪种标准,HFA SITA标准检出的视野进展率总体均高于FDT2(P<0.001)。
核心结论
- HFA SITA标准视野检查识别青光眼视野进展的比率至少不低于FDT2,总体高于FDT2(P<0.001)。
研究设计与样本
- 120例青光眼患者在基线和随后4年中每6个月接受一次HFA SITA标准自动视野检查和FDT2检查,共两次基线检查。
- FDT2数值被标准化为HFA SAP数值,采用逐点线性回归(PLR)分析全部数据序列以判定青光眼进展。
主要发现
- 按三种标准(≥3个聚集测试点进展、≥3个非聚集测试点进展、进展测试点总数)比较,HFA SITA标准检出的视野进展率总体均高于FDT2(P<0.001)。
关键数值与推荐
- 进展判定标准一:3个或以上聚集测试点进展。
- 进展判定标准二:3个或以上非聚集测试点进展。
- 进展判定标准三:进展测试点总数。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The Humphrey Matrix (FDT2) may be more sensitive in detecting glaucomatous visual field loss than SITA standard automated perimetry (SAP) performed on the Humphrey Field Analyzer (HFA). Therefore, FDT may be a good candidate to determine disease progression in patients with glaucoma. Our aim was to test the hypothesis that automated perimetry using the FDT2 would be equal to, or more effective than, HFA SITA-Standard, in identifying glaucomatous progression. METHODS: One hundred and twenty patients with glaucoma were tested twice at baseline and every 6 months for 4 years with HFA SITA-Standard and FDT2. FDT2 values were standardised to HFA SAP values. We used pointwise linear regression (PLR) over the full data series to identify glaucomatous progression and generated an array of results using three different criteria: (1) three or more clustered test locations progressing, (2) three or more non-clustered test locations progressing and (3) total number of progressing test locations. We compared HFA SAP and FDT2 for the number of locations signalled by the PLR detection algorithm. RESULTS: Regardless of the criteria, HFA SAP with SITA-Standard testing detected visual field progression at a higher rate than the FDT2 overall (P<0.001). CONCLUSION: HFA SAP identifies glaucomatous visual field progression at a rate at least as high if not higher than FDT2.
引用
- Wall M, Johnson CA, Zamba KD, et al. SITA-Standard perimetry has better performance than FDT2 matrix perimetry for detecting glaucomatous progression. Br J Ophthalmol. 2018. PMID: 29331951. doi:10.1136/bjophthalmol-2017-310894
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。