比较眼底荧光素血管造影与扫频源光学相干断层扫描血管成像在糖尿病黄斑灌注评估中的应用
研究纳入21例糖尿病患者的41只眼,在Moorfields眼科医院1个月内完成彩色眼底照相、眼底荧光素血管造影(FFA)及扫频源光学相干断层扫描血管成像(SS-OCTA)两种扫描方案(3×3 mm与4.5×4.5 mm)的毛细血管浅层 plexus 成像,定量评估中心凹无血管区直径与面积、定性分析及糖尿病黄斑缺血分级。结果显示SS-OCTA在中心凹无血管区分析中可重复性好,与FFA一致性有限,尤其在糖尿病黄斑缺血分级方面;FFA识别微动脉瘤更敏感。
要点
- SS-OCTA在糖尿病黄斑灌注评估中,中心凹无血管区分析可重复性好。
- FFA与SS-OCTA在糖尿病黄斑缺血分级上一致性低至中等。
- FFA识别微动脉瘤较SS-OCTA更敏感。
核心结论
- 扫频源OCTA在糖尿病患者的黄斑灌注评估中是一种可重复的技术,尤其在中心凹无血管区分析方面。
- 其与FFA的一致性有限,尤其在糖尿病黄斑缺血分级方面。
- 眼底荧光素血管造影在识别微动脉瘤方面更敏感。
研究设计与样本
- 研究纳入21例糖尿病患者的41只眼,于Moorfields眼科医院(伦敦)在1个月间隔内接受彩色眼底照相、FFA及SS-OCTA毛细血管浅层 plexus 成像,SS-OCTA采用3×3 mm与4.5×4.5 mm两种扫描方案。
- 进行定量评估(中心凹无血管区直径与面积)、定性分析(宏观与微观水平)及早期治疗糖尿病视网膜病变研究糖尿病黄斑缺血分级,并记录伪影,计算组内相关系数与加权kappa值。
主要发现
- 中心凹无血管区面积均值(标准差):FFA为0.695(0.52)mm,SS-OCTA 3×3方案为0.627(0.54)mm,SS-OCTA 4.5×4.5方案为0.701(0.54)mm。
- 组内相关系数显示FFA与SS-OCTA在垂直直径及中心凹无血管区面积测量上一致性良好。
- SS-OCTA 3×3与4.5×4.5两种方案在所有定量测量上一致性良好。
- 糖尿病黄斑缺血分级的加权kappa显示FFA与SS-OCTA一致性低至中等,而两种SS-OCTA方案间一致性良好。
关键数值与推荐
- 中心凹无血管区面积均值(标准差):FFA 0.695(0.52)mm,SS-OCTA 3×3方案0.627(0.54)mm,SS-OCTA 4.5×4.5方案0.701(0.54)mm。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare fundus fluorescein angiography (FFA) and swept-source optical coherence tomography angiography (SS-OCTA) in the evaluation of macular perfusion in diabetic patients. METHODS: Forty-one eyes (21 diabetic patients) seen at Moorfields Eye Hospital (London) over a 1-month interval underwent color fundus photography, FFA, and SS-OCTA imaging of the capillary superficial plexus using 2 different protocols: 3 × 3 mm and 4.5 × 4.5 mm. Quantitative assessment (foveal avascular zone diameters and area), qualitative analysis (macroscopic and microscopic levels) and Early Treatment Diabetic Retinopathy Study diabetic macular ischemia grading were performed. Artifacts were recorded. Intraclass correlation coefficients and weighted kappa values were calculated. RESULTS: Mean (SD) foveal avascular zone area was 0.695 (0.52) mm on FFA, 0.627 (0.54) mm on SS-OCTA 3 × 3 and 0.701 (0.54) mm on SS-OCTA 4.5 × 4.5 protocol. Intraclass correlation coefficients showed good agreement between FFA and SS-OCTA for both vertical diameter and foveal avascular zone area measurements. The agreement between SS-OCTA 3 × 3 and 4.5 × 4.5 was good for all quantitative measurements. Weighted kappa for diabetic macular ischemia grading showed low to fair agreement between FFA and SS-OCTA, whereas the agreement was good between two different SS-OCTA protocols. CONCLUSION: Swept-source OCTA is a reproducible technique in the assessment of macular perfusion in diabetic patients with special regards to foveal avascular zone analysis. The agreement with FFA is limited especially for diabetic macular ischemia grading. Fundus fluorescein angiography is more sensitive in identifying microaneurysms.
引用
- La Mantia A, Kurt RA, Mejor S, et al. COMPARING FUNDUS FLUORESCEIN ANGIOGRAPHY AND SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IN THE EVALUATION OF DIABETIC MACULAR PERFUSION. Retina. 2019. PMID: 29346244. doi:10.1097/IAE.0000000000002045
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。