文献速递角膜与眼表疾病

羧甲基化透明质酸基聚合物膜与眼表的摩擦系数

Coefficient of Friction Between Carboxymethylated Hyaluronic Acid-Based Polymer Films and the Ocular Surface.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2017-01-01

本研究在三种轴向载荷(0.3、0.5、0.7 N)和四种滑动速度(0.3、1.0、10、30 mm/s)下,量化了含与不含甲基纤维素的羧甲基化透明质酸基聚合物(CMHA-S)对羊和人巩膜的摩擦相互作用。结果显示静摩擦系数随速度显著增加(P < 0.003),动摩擦系数不受速度影响,加入甲基纤维素使静摩擦和动摩擦分别增加60%和80%,但甲基纤维素在测试中易磨损。作者认为甲基纤维素可在膜上形成摩擦差异,但设计时须考虑其可能增加降解速率。

要点

  • 静摩擦系数随滑动速度增加而显著增大(P < 0.003)。
  • 动摩擦系数不受滑动速度影响,平均为0.15 ± 0.1。
  • 甲基纤维素使CMHA-S静摩擦和动摩擦分别增加60%和80%,但易磨损。

核心结论

  • 数据提示甲基纤维素可用于在膜上形成摩擦差异,但设计时必须考虑甲基纤维素可能增加降解速率。

研究设计与样本

  • 在三种轴向载荷(0.3、0.5和0.7 N)和四种滑动速度(0.3、1.0、10和30 mm/s)下,量化含与不含甲基纤维素的羧甲基化透明质酸基聚合物(CMHA-S)对羊和人巩膜的摩擦相互作用。

主要发现

  • 静摩擦系数随速度显著增加(P < 0.003),在0.3至30 mm/s范围内分别为0.18 ± 0.08至0.46 ± 0.13。
  • 加入甲基纤维素后CMHA-S的摩擦更依赖速度。
  • 动摩擦系数不受速度影响,平均为0.15 ± 0.1。
  • 甲基纤维素使CMHA-S的静摩擦和动摩擦分别增加60%和80%,但甲基纤维素在测试中也易磨损。

局限性

  • 甲基纤维素在测试中易磨损。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Hyaluronic acid-based polymer films are emerging as drug-delivery vehicles for local and continuous drug administration to the eye. The highly lubricating hyaluronic acid increases comfort, but displaces films from the eye, reducing drug exposure and efficacy. Previous studies have shown that careful control of the surface interaction of the film with the eye is critical for improved retention. METHODS: In this study, the frictional interaction of a carboxymethylated, hyaluronic acid-based polymer (CMHA-S) with and without methylcellulose was quantified against ovine and human sclera at three axial loads (0.3, 0.5, and 0.7 N) and four sliding velocities (0.3, 1.0, 10, and 30 mm/s). RESULTS: Static coefficients of friction significantly increased with rate (P < 0.003), ranging between 0.18 ± 0.08 and 0.46 ± 0.13 for 0.3 to 30 mm/s, respectively. Friction became more rate-dependent when methylcellulose was added to CMHA-S. Kinetic coefficient of friction was not affected by rate, and averaged 0.15 ± 0.1. Methylcellulose increased CMHA-S static and kinetic friction by 60% and 80%, respectively, but was also prone to wear during testing. CONCLUSIONS: These data suggest that methylcellulose can be used to create a friction differential on the film, but a potentially increased degradation rate with the methylcellulose must be considered in the design.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Colter J, Wirostko B, Coats B, et al. Coefficient of Friction Between Carboxymethylated Hyaluronic Acid-Based Polymer Films and the Ocular Surface. Invest Ophthalmol Vis Sci. 2017. PMID: 29222545. doi:10.1167/iovs.17-22414

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。