文献速递角膜与眼表疾病

气动分离失败后采用黏弹剂泡行深板层角膜移植术的结果

Results of viscobubble deep anterior lamellar keratoplasty after failure of pneumatic dissection.
PubMed 文献 · Br J Ophthalmol · 2017-12-23

该研究在140只圆锥角膜眼中先行气动分离,失败后改行基质内注射眼科黏弹剂(OVD)形成大气泡并完成深板层角膜移植术(DALK)。气动注射形成大气泡106/140眼(75.71%),OVD注射在剩余30眼中形成大气泡28眼(93.33%,占总眼数20%),联合成功率95.71%。OVD辅助分离失败后手法分离困难,导致严重界面混浊和视力预后差。

要点

  • 气动分离失败后基质内注射OVD可使大气泡形成率从75.71%提高至95.71%。
  • OVD注射在气动失败后的30眼中形成大气泡28眼(93.33%,占总眼数20%)。
  • OVD辅助分离失败后手法分离困难,2眼出现深皱褶、界面混浊和最佳矫正视力下降。

核心结论

  • 气动分离失败后基质内注射OVD可大幅提高大气泡形成成功率(本组从75.71%升至95.71%)。
  • 但OVD辅助分离失败时,OVD浸润残留基质使手法分离特别困难,并导致严重界面混浊和视力预后差。

研究设计与样本

  • 对130例患者140只圆锥角膜眼行DALK,先尝试气动分离,失败后仅二次注射空气和OVD。
  • 记录空气和OVD注射后大气泡形成率,评估并发症、最佳矫正视力(BSCVA)和角膜断层参数。
  • 评估时间点为术后3个月、6个月、12个月以及完全拆线后。

主要发现

  • 空气注射在106/140眼(75.71%)形成大气泡。
  • OVD注射未在4眼中尝试(插管时穿孔n=2;气泡破裂n=2),在剩余30眼中形成大气泡28眼(93.33%,占总眼数20%)。
  • OVD辅助分离失败后2/30眼(6.66%,占总眼数1.42%)需手法分离,且这2眼均出现深皱褶、界面混浊和BSCVA下降。
  • 气动辅助组BSCVA在术后仅3个月内统计学优于OVD辅助组(P=0.01),此后两次技术间无统计学显著差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To report the outcomes of bubble formation obtained by means of intrastromal injection of ophthalmic viscoelastic device (OVD) after failure of pneumatic dissection for deep anterior lamellar keratoplasty (DALK). METHODS: DALK was performed in 140 keratoconic eyes of 130 patients by injecting air and OVD only secondarily, after pneumatic dissection had failed; the bubble formation rates after air and OVD injection were recorded; complications, best spectacle-corrected visual acuity (BSCVA) and corneal tomographic parameters were evaluated 3 months, 6 months and 12 months postoperatively, as well as after complete suture removal. RESULTS: Air injection created a big bubble in 106/140 eyes (75.71%); OVD injection was not attempted in 4 eyes (perforation during cannula insertion n=2; air bubble burst n=2) and created a big bubble in 28 of the remaining 30 eyes (93.33%, 20% of the total). Manual dissection was required in 2/30 eyes (6.66%, 1.42% of the total) after failed OVD-assisted dissection.Deep folds, interface opacity and reduced BSCVA were noted in both eyes after failed OVD-assisted dissection. BSCVA was statistically better after pneumatic-assisted than after OVD-assisted dissection (P 0.01) only up to 3 months postoperatively; no statistically significant differences were recorded between the two techniques at later examinations. CONCLUSION: Intrastromal injection of OVD after failed pneumatic dissection increases considerably the success rate of bubble formation (from 75.71% to 95.71% in our series); however, when bubble formation fails, infiltration of OVD into the residual stroma makes manual dissection particularly challenging and causes severe interface haze resulting in poor visual outcomes.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Scorcia V, De Luca V, Lucisano A, et al. Results of viscobubble deep anterior lamellar keratoplasty after failure of pneumatic dissection. Br J Ophthalmol. 2017. PMID: 29275378. doi:10.1136/bjophthalmol-2017-311419

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。