评估MP-3微视野计在青光眼患者中的实用性
本研究纳入30例原发性开角型青光眼患者的30只眼,用MP-3与Humphrey视野分析仪(HFA)以10-2测试网格各测量两次视野,并用OCT测量黄斑区神经节细胞复合体(GCC)厚度。结果显示MP-3测量时间显著长于HFA,但两者的平均绝对偏差(MAD)与组内相关系数(ICC)无显著差异,且MP-3视野敏感度与GCC厚度的结构-功能关系更强。
要点
- MP-3测量时间10分29秒±2分55秒,显著长于HFA的7分06秒±0分49秒(P < .001)。
- HFA的MAD为0.83±0.69 dB、ICC为0.89±0.69,MP-3的MAD为0.65±0.67 dB、ICC为0.89±0.69,两者无显著差异。
- MP-3视野敏感度与GCC厚度的结构-功能关系强于HFA。
核心结论
- MP-3微视野计的重复测试再现性与HFA相似,但结构-功能关系更好。
研究设计与样本
- 信度与效度研究,纳入30例原发性开角型青光眼患者的30只眼,每只眼用MP-3和HFA以10-2测试网格各测量视野两次,并用OCT测量GCC厚度。
主要发现
- HFA 10-2平均测量时间为7分06秒±0分49秒,MP-3为10分29秒±2分55秒,MP-3显著更长(P < .001,配对Wilcoxon检验)。
- HFA的MAD为0.83±0.69 dB、ICC为0.89±0.69,MP-3的MAD为0.65±0.67 dB、ICC为0.89±0.69,两者MAD与ICC均无显著差异。
- MP-3视野敏感度与GCC厚度的结构-功能关系强于HFA。
关键数值与推荐
- 重复测试再现性以全部68个视野测试点的平均绝对偏差(MAD)和重复视野敏感度的组内相关系数(ICC)评估。
- 结构-功能关系采用线性混合模型分析视野敏感度与经视网膜神经节细胞位移校正后的GCC厚度之间的关系。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The purpose of the current study was to evaluate the test-retest reproducibility and structure-function relationship of the MP-3 microperimeter, compared against the Humphrey Field Analyzer (HFA). METHODS: Design: Reliability and validity study. SETTING: Institutional, or clinical practice. STUDY POPULATION: Thirty eyes of 30 primary open-angle glaucoma patients were enrolled. OBSERVATION PROCEDURES: Visual fields (VF) were measured twice with the MP-3 and HFA instruments, using the 10-2 test grid pattern in both perimeters. Ganglion cell complex (GCC) thickness was measured using optical coherence tomography (OCT). Test-retest reproducibility was assessed using the mean absolute deviation (MAD) measure at all 68 VF test points, and also the intraclass correlation coefficient (ICC) of the repeated VF sensitivities. The structure-function relationship between VF sensitivities (measured with MP-3 or HFA) and GCC thickness (adjusted for the retinal ganglion cell displacement) was analyzed using linear mixed modeling. MAIN OUTCOME MEASURE: Reproducibility and structure-function relationship. RESULTS: The average measurement duration with the HFA 10-2 was 7 minutes and 6 seconds (7m06s) ± 0m49s (mean ± standard deviation). A significantly (P < .001, paired Wilcoxon test) longer measurement duration was observed for the MP-3 test: 10m29s ± 2m55s. There were no significant differences in MAD and ICC values between HFA (MAD; 0.83 ± 0.69 dB and ICC: 0.89 ± 0.69, mean ± standard deviation) and MP-3 (MAD: 0.65 ± 0.67 dB and ICC: 0.89 ± 0.69). MP-3 VF sensitivities had a stronger structure-function relationship with GCC thickness compared to HFA. CONCLUSIONS: The MP-3 microperimeter has a similar test-retest reproducibility to the HFA but a better structure-function relationship.