文献速递青光眼眼底病与葡萄膜炎

原发性开角型青光眼伴单侧视野缺损患者的视盘周围与黄斑血管密度

Peripapillary and Macular Vessel Density in Patients with Primary Open-Angle Glaucoma and Unilateral Visual Field Loss.
PubMed 文献 · Ophthalmology · 2017-11-22

横断面研究纳入33例单眼视野缺损的原发性开角型青光眼患者和33只健康眼,用OCT血管成像测量血管密度并与结构参数比较。未受影响眼的全图像血管密度低于健康眼但高于对侧 affected 眼,鉴别未受影响眼与健康眼的AUC以全图像血管密度最高(0.84)。作者认为OCT-A可在视野损害前检测到视网膜微血管改变,但需纵向研究验证。

要点

  • 未受影响眼全图像血管密度52.0%,低于健康眼55.9%,高于对侧 affected 眼48.8%(P < 0.001)。
  • 鉴别未受影响眼与健康眼AUC:全图像血管密度0.84,黄斑神经节细胞复合体0.78,视盘周围RNFL 0.77,旁中心凹血管密度0.69。
  • 作者结论认为OCT-A可在视野损害前检测到微血管改变,但需纵向研究确定其价值。

核心结论

  • OCT-A检测可在原发性开角型青光眼患者视野损害可检测之前发现视网膜微血管改变,这些改变可能反映与青光眼病理生理相关组织的损伤。
  • 需要纵向研究来确定OCT-A测量能否改善青光眼发病和进展的检测或预测。

研究设计与样本

  • 横断面研究,纳入33例单眼视野缺损(平均视野平均偏差-3.9±3.1 dB)而对侧眼视野正常(平均视野平均偏差-0.2±0.9 dB)的原发性开角型青光眼患者,以及33只健康眼。
  • 所有受试者接受OCT血管成像、频域OCT成像和视野检查。
  • 比较青光眼眼与健康眼的眼间血管测量差异,以及频域OCT视网膜神经纤维层、黄斑神经节细胞复合体厚度和盘沿面积测量。
  • 用受试者工作特征曲线下面积评估未受影响眼与健康眼鉴别的诊断准确性。

主要发现

  • 未受影响眼平均全图像血管密度52.0%,高于对侧 affected 眼48.8%,低于健康眼55.9%(P < 0.001)。
  • 未受影响眼平均视盘周围视网膜神经纤维层厚度87.5 μm、黄斑神经节细胞复合体厚度87.7 μm、盘沿面积1.0 mm2,高于对侧 affected 眼(76.5 μm、79.5 μm、0.8 mm2;P < 0.001),低于健康眼(98.0 μm、94.5 μm、1.4 mm2;P < 0.001)。
  • 鉴别未受影响眼与健康眼的AUC以全图像血管密度最高(0.84),其次为黄斑神经节细胞复合体(0.78)、视盘周围视网膜神经纤维层(0.77)和旁中心凹血管密度(0.69)。

关键数值与推荐

  • 未受影响眼平均视野平均偏差-0.2±0.9 dB,对侧 affected 眼-3.9±3.1 dB。
  • 未受影响眼全图像血管密度52.0%,对侧 affected 眼48.8%,健康眼55.9%(P < 0.001)。
  • 未受影响眼视盘周围视网膜神经纤维层厚度87.5 μm、黄斑神经节细胞复合体厚度87.7 μm、盘沿面积1.0 mm2;对侧 affected 眼分别为76.5 μm、79.5 μm、0.8 mm2(P < 0.001);健康眼分别为98.0 μm、94.5 μm、1.4 mm2(P < 0.001)。
  • 鉴别未受影响眼与健康眼的AUC:全图像血管密度0.84、黄斑神经节细胞复合体0.78、视盘周围视网膜神经纤维层0.77、旁中心凹血管密度0.69。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文结论指出需要纵向研究来确定OCT-A测量能否改善青光眼发病和进展的检测或预测。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To characterize OCT angiography (OCT-A) vessel density of patients with primary open-angle glaucoma (POAG) with unilateral visual field (VF) loss. DESIGN: Cross-sectional study. PARTICIPANTS: A total of 33 patients with POAG with a VF defect in 1 eye (mean VF mean deviation [MD], -3.9±3.1 decibels [dB]) and normal VF in the other eye (mean VF MD, -0.2±0.9 dB) and 33 healthy eyes. METHODS: All subjects underwent OCT-A imaging, spectral-domain (SD)-OCT imaging, and VF testing. OCT-A retinal vascular measurements were summarized as whole image vessel density (wiVD), circumpapillary vessel density (cpVD), and parafoveal vessel density (pfVD). Inter-eye differences in vascular measures, as well as SD OCT retinal nerve fiber layer (RNFL), macular ganglion cell complex (mGCC) thickness, and rim area measurements in glaucoma and healthy eyes were compared. Areas under the receiver operating characteristic curves (AUROCs) were used to evaluate diagnostic accuracy for differentiating between unaffected eyes of patients with POAG and healthy eyes. MAIN OUTCOME MEASURES: Difference in OCT-A vessel density and SD OCT structural parameters between unaffected eyes of patients with POAG with the fellow affected eyes and healthy controls. RESULTS: Mean wiVD in unaffected eyes of patients with POAG (52.0%) was higher than in their fellow affected eyes (48.8%) but lower than in healthy eyes (55.9%; P < 0.001). Mean circumpapillary RNFL (cpRNFL) thickness, mGCC thickness, and rim area measurement in unaffected eyes of patients with POAG (87.5 μm, 87.7 μm, and 1.0 mm2) were also higher than those measurements in their fellow eyes (76.5 μm, 79.5 μm, and 0.8 mm2; P < 0.001) and lower than in healthy eyes (98.0 μm, 94.5 μm, and 1.4 mm2; P < 0.001). The AUROCs for differentiating unaffected eyes of patients with POAG from healthy eyes were highest for wiVD (0.84), followed by mGCC (0.78), cpRNFL (0.77), and pfVD (0.69). CONCLUSIONS: OCT-A measures detect changes in retinal microvasculature before VF damage is detectable in patients with POAG, and these changes may reflect damage to tissues relevant to the pathophysiology of glaucoma. Longitudinal studies are needed to determine whether OCT-A measures can improve the detection or prediction of the onset and progression of glaucoma.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Yarmohammadi A, Zangwill LM, Manalastas PIC, et al. Peripapillary and Macular Vessel Density in Patients with Primary Open-Angle Glaucoma and Unilateral Visual Field Loss. Ophthalmology. 2017. PMID: 29174012. doi:10.1016/j.ophtha.2017.10.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。