健康中国人施莱姆管形态与眼压的昼夜变化:一项SS-OCT研究
该研究用扫频源光学相干断层扫描(SS-OCT)在5个时间点(上午8点、11点、下午2点、5点、晚8点)对51名健康受试者102只眼进行施莱姆管(SC)成像并同步测量眼压(IOP)。结果显示仅下方象限SC面积和直径的变化与IOP变化呈负相关(P=0.0046和P=0.0332),Valsalva动作(VM)期间SC面积和直径显著高于动作前(P<0.001)。
要点
- 仅下方象限施莱姆管面积和直径的变化与眼压变化呈负相关。
- Valsalva动作期间施莱姆管面积和直径显著高于动作前(P<0.001)。
- 施莱姆管检出率在上方象限最高(85.3%),下方象限最低(75.5%)。
核心结论
- 施莱姆管参数的变化仅在下方象限与眼压变化呈负相关。
- Valsalva动作可使健康受试者的施莱姆管扩张。
- 施莱姆管成像未来可能成为探究眼压波动原因及白天施莱姆管形态变化的方法。
研究设计与样本
- 用扫频源光学相干断层扫描(SS-OCT)在体成像51名健康受试者102只眼的颞侧、鼻侧、下方和上方角膜缘,时间点为上午8点、11点、下午2点、5点和晚8点。
- 同一时间点用Goldmann压平眼压计(GAT)测量眼压,在ImageJ中测量施莱姆管直径和横截面积。
- 用广义估计方程模型分析施莱姆管参数变化、眼压及其他生物测量参数之间的关联。
- 另对47名健康受试者94只眼的颞侧和下方角膜缘在晚8点于Valsalva动作前及动作期间进行成像。
主要发现
- 不同时间点的平均眼压分别为13.37、12.89、11.9、12.02和12.36 mm Hg。
- 四个象限中施莱姆管检出率在上方象限最高(85.3%),下方象限最低(75.5%)。
- 校正年龄、性别、眼别、等效球镜和眼轴长度后,仅下方象限施莱姆管面积和直径的变化与眼压变化呈负相关(分别为P=0.0046和P=0.0332)。
- Valsalva动作期间平均施莱姆管面积和直径显著高于动作前(P<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To characterize the diurnal variations in the dimensions of the Schlemm's canal (SC) and its association with intraocular pressure (IOP) using swept-source optical coherence tomography (SS-OCT). METHODS: The temporal, nasal, inferior, and superior limbus of 102 eyes of 51 healthy subjects were imaged in vivo by SS-COT at 5 time points of 8 AM, 11 AM, 2 PM, 5 PM, and 8 PM. IOP was measured at the same time by Goldmann applanation tonometry (GAT). The diameter and the cross-sectional area of the SC were measured in ImageJ. The associations between changes in the SC parameters, IOP, and other biometric parameters were determined using a general estimating equations model. The temporal and inferior limbus of 94 eyes of 47 healthy subjects were also imaged before and during the Valsalva maneuver (VM) at 8 PM. RESULTS: Mean IOPs at different time points were 13.37, 12.89, 11.9, 12.02, and 12.36 mm Hg. Of all four quadrants, the detectable rate of SC was highest in the superior quadrant (85.3%) and lowest in the inferior quadrant (75.5%). We found that changes in the SC area and diameter were negatively associated with IOP changes only in the inferior quadrant (P = 0.0046 and P = 0.0332, respectively), after adjusting for age, sex, eye, spherical equivalent, and axial length. The mean SC area and diameter during the VM were significantly higher than prior to the VM (P < 0.001). CONCLUSIONS: The changes in the SC parameters were negatively associated with IOP changes only in the inferior quadrant. The VM could expand the SC in healthy subjects. Imaging of the SC may be a useful method to discover the reason why IOP fluctuates, and how SC changes morphologically during the daytime in the future.
引用
- Gao K, Li F, Aung T, et al. Diurnal Variations in the Morphology of Schlemm's Canal and Intraocular Pressure in Healthy Chinese: An SS-OCT Study. Invest Ophthalmol Vis Sci. 2017. PMID: 29117278. doi:10.1167/iovs.17-22019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。