高度近视中的眼压与青光眼性视神经病变
该院基观察性研究纳入东京高度近视诊所261例患者共517眼,基于眼底照片定义青光眼性视神经病变(GON)。GON患病率为27.3%(95%CI:23.4,31.0);眼轴≤27.4mm眼中GON仅与较高眼压相关(OR:1.35;95%CI:1.02,1.80),眼轴≥27.5mm眼中GON与较大视盘、较长眼轴和较大年龄相关,而与眼压无显著关联。
要点
- 高度近视人群中GON患病率为27.3%(95%CI:23.4,31.0)。
- 眼轴≤27.4mm眼中,GON与较高眼压相关(OR:1.35;95%CI:1.02,1.80)。
- 眼轴≥27.5mm眼中,GON与较大视盘、较长眼轴和较大年龄相关,与眼压无显著关联。
核心结论
- 在眼轴≤27.4mm的近视眼中,GON与眼压升高相关;而在眼轴≥27.5mm的高度近视眼中,较大视盘、较长眼轴和较大年龄是与GON相关的因素,眼压(多在正常范围内)则不是。
- 作者提出,未来研究可探讨异常低的眼压是否与高度近视眼中较低的GON患病率相关。
研究设计与样本
- 医院为基础的观察性研究,纳入在东京高度近视诊所接受治疗且有眼底照片和眼压读数的患者。
- 共纳入261例患者517眼,平均年龄62.1±14.2岁(范围13-89岁),平均眼轴29.5±2.2mm(范围23.2-35.3mm)。
- 以眼底照片上视神经乳头的表现作为GON的定义依据。
主要发现
- 517眼中141眼(27.3%;95%CI:23.4,31.0)存在GON。
- 青光眼组平均眼压14.5±3.3mmHg(中位数14mmHg;范围8-38mmHg),非青光眼组平均眼压14.7±2.5mmHg(中位数14mmHg;范围6-23mmHg),两组差异无统计学显著(P=0.53)。
- 眼轴≤27.4mm的眼中,GON的存在仅与较高眼压相关(P=0.037;OR:1.35;95%CI:1.02,1.80)。
- 眼轴≥27.5mm的眼中,GON的存在与较大年龄(P<0.001;OR:1.05;95%CI:1.03,1.08)、较长眼轴(P<0.001;OR:1.60;95%CI:1.34,1.91)、较短颞侧动脉弓垂直直径(P=0.009;OR:0.82;95%CI:0.71,0.95)和较长视盘最小直径(P=0.002;OR:3.07;95%CI:1.52,6.21)相关。
- 在眼轴≥27.5mm的眼中,若将眼压加入模型,眼压与GON患病率无显著关联(P=0.97;OR:1.00;95%CI:0.91,1.10)。
关键数值与推荐
- GON定义依据为眼底照片上视神经乳头的表现。
- 眼轴≤27.4mm眼中GON与眼压的OR为1.35(95%CI:1.02,1.80;P=0.037)。
- 眼轴≥27.5mm眼中GON与年龄的OR为1.05(95%CI:1.03,1.08;P<0.001),与眼轴的OR为1.60(95%CI:1.34,1.91;P<0.001),与颞侧动脉弓垂直直径的OR为0.82(95%CI:0.71,0.95;P=0.009),与视盘最小直径的OR为3.07(95%CI:1.52,6.21;P=0.002)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To examine the association between intraocular pressure (IOP) and the prevalence of glaucomatous optic neuropathy (GON) in high myopia. METHODS: The hospital-based observational study consisted of patients treated in the Tokyo High Myopia Clinics and for whom fundus photographs and IOP readings were available. The appearance of the optic nerve head on fundus photographs was the basis for the definition of GON. RESULTS: Among 517 eyes of 261 patients (mean age: 62.1 ± 14.2 years; range: 13-89 years; mean axial length: 29.5 ± 2.2 mm; range: 23.2-35.3 mm), GON was present in 141 eyes (27.3%; 95% confidence intervals [CIs]: 23.4, 31.0). Mean IOP did not differ significantly (P = 0.53) between the glaucoma group (14.5 ± 3.3 mm Hg; median: 14 mm Hg; range: 8-38 mm Hg) and the nonglaucomatous group (14.7 ± 2.5 mm Hg; median: 14 mm Hg; range: 6-23 mm Hg). In eyes with an axial length of ≤27.4 mm, higher presence of GON was correlated only with higher IOP (P = 0.037; odds ratio [OR]:1.35; 95% CI: 1.02, 1.80). In eyes with an axial length of ≥27.5 mm, presence of GON was correlated with older age (P < 0.001; OR: 1.05; 95% CI :1.03, 1.08), longer axial length (P < 0.001; OR: 1.60; 95% CI: 1.34, 1.91), shorter vertical diameter of the temporal arterial arcade (P = 0.009; OR: 0.82; 95% CI: 0.71, 0.95), and longer minimal optic disc diameter (P = 0.002; OR: 3.07; 95% CI: 1.52, 6.21). If IOP was added to the model, it was not significantly associated with the prevalence of GON (P = 0.97; OR: 1.00; 95% CI: 0.91, 1.10). CONCLUSIONS: GON was associated with elevated IOP in myopic eyes with an axial length of ≤27.4 mm, while in more highly myopic eyes (axial length ≥27.5 mm), larger optic disc, longer axial elongation and older age-but not IOP mostly within its normal range-were factors associated with GON. Future studies may examine an abnormally low IOP to be associated with a lower GON prevalence in highly myopic eyes.
引用
- Jonas JB, Nagaoka N, Fang YX, et al. Intraocular Pressure and Glaucomatous Optic Neuropathy in High Myopia. Invest Ophthalmol Vis Sci. 2017. PMID: 29164230. doi:10.1167/iovs.17-21942
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。