充气下吊灯辅助周边玻璃体切除术中巩膜自压陷治疗孔源性视网膜脱离:一项回顾性队列研究
回顾性队列研究纳入130只原发性孔源性视网膜脱离眼,均行充气下吊灯辅助周边玻璃体切除术,68只眼采用巩膜自压陷(压陷组),62只眼未压陷(非压陷组)。压陷组修剪所致视网膜裂孔眼数少于非压陷组(0/68 vs 3/62,0% vs 4.8%,P=0.04),巩膜压陷组需吊灯重新定位的眼数少于非压陷组(22 vs 46,P<0.001)。
要点
- 压陷组修剪所致视网膜裂孔为0/68眼(0%),非压陷组为3/62眼(4.8%),P=0.04。
- 压陷组视网膜再脱离1/68眼,非压陷组3/62眼,P=0.267。
- 压陷组需吊灯重新定位22眼,非压陷组46眼,P<0.001。
核心结论
- 充气下吊灯辅助周边玻璃体切除术中行巩膜自压陷可完整修剪玻璃体基底部而不造成医源性视网膜裂孔,视网膜复位率更高,且吊灯重新定位需求少于非压陷法。
- 作者认为巩膜自压陷是充气下吊灯辅助玻璃体切除术的一个优势,与既往报道相反。
研究设计与样本
- 回顾性队列研究,纳入130只原发性孔源性视网膜脱离眼,均行充气下吊灯辅助周边玻璃体切除术。
- 巩膜自压陷用于68只眼(研究组;压陷组),非压陷用于62只眼(对照组;非压陷组)。
主要发现
- 修剪所致视网膜裂孔眼数压陷组0/68眼(0%)少于非压陷组3/62眼(4.8%),P=0.04。
- 视网膜再脱离压陷组1/68眼,非压陷组3/62眼,P=0.267。
- 两组间logMAR最佳矫正视力无统计学显著差异(P=0.229)。
- 需吊灯重新定位者压陷组22眼,非压陷组46眼,P<0.001。
关键数值与推荐
- 结局变量包括修剪所致视网膜裂孔、视网膜再脱离率、最终logMAR最佳矫正视力和术中并发症。
临床怎么用
- 作者认为巩膜自压陷是充气下吊灯辅助玻璃体切除术的一个优势,与既往报道相反。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate incidence of iatrogenic retinal breaks in eyes for whom self-indentation during chandelier-assisted peripheral vitrectomy under air, for primary retinal detachment, had been performed compared with eyes for whom a nonindentation chandelier-assisted peripheral vitrectomy under air had been performed. METHODS: Retrospective cohort study. One hundred and thirty eyes with primary rhegmatogenous retinal detachment were identified. All the patients had undergone a chandelier-assisted peripheral vitrectomy under air. Scleral self-indentation had been used in 68 eyes (study group; indentation), whereas nonindentation had been used in 62 eyes (comparison; nonindentation). Outcome variables included the following: trimming-induced retinal breaks, retinal redetachment rate, final logMAR best-corrected visual acuity, and intraoperative complications. RESULTS: The number of eyes with trimming-induced retinal break was statistically less in indentation group than in nonindentation group (0/68 and 3/62 eyes, 0% and 4.8%, respectively) (P = 0.04). Redetachment was observed in one eye (indentation) (1/68) and in three eyes (nonindentation) (3/62) (P = 0.267). There was no statistically significant difference in logMAR best-corrected visual acuity between both groups (P = 0.229). Chandelier repositioning was needed in 22 eyes (indentation) compared with 46 eyes (nonindentation) (P < 0.001). CONCLUSION: Self-indentation, during chandelier-assisted peripheral vitrectomy under air, enables complete trimming of the vitreous base without causing iatrogenic retinal breaks, with a higher retinal reattachment rate, and with less need for chandelier repositioning than with nonindentation approach. By contrast with previous reports, we consider scleral self-indentation as an advantage for chandelier air vitrectomy.
引用
- Ewais WA, Nossair AA, Aly LS, et al. SCLERAL SELF-INDENTATION DURING CHANDELIER-ASSISTED PERIPHERAL VITRECTOMY UNDER AIR FOR RHEGMATOGENOUS RETINAL DETACHMENT: A Retrospective Cohort Study. Retina. 2019. PMID: 29117070. doi:10.1097/IAE.0000000000001955
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。