应用白细胞介素-10及IL-10/IL-6比值阈值在眼内样本中筛查玻璃体视网膜淋巴瘤
纳入119例(16例最终诊断为玻璃体视网膜淋巴瘤,103例为葡萄膜炎)已检测房水和/或玻璃体IL-10、IL-6的患者,比较两组细胞因子水平及 demographic 数据。玻璃体IL-10阈值65 pg/mL灵敏度93%、特异度100%,房水IL-10阈值30 pg/mL灵敏度78%、特异度97%;玻璃体IL-10/IL-6比值>1灵敏度93%、特异度100%。作者认为IL-10及IL-10/IL-6比值阈值可能有助于更早诊断并可能改善预后。
要点
- 玻璃体IL-10阈值65 pg/mL筛查VRL的灵敏度93%、特异度100%。
- 房水IL-10阈值30 pg/mL筛查VRL的灵敏度78%、特异度97%。
- 玻璃体IL-10/IL-6比值>1筛查VRL的灵敏度93%、特异度100%。
核心结论
- 玻璃体视网膜淋巴瘤诊断困难,检测房水和玻璃体中的白细胞介素等工具可使其更容易。
- 使用IL-10及IL-10/IL-6比值的阈值可能允许更早诊断,并可能改善预后。
研究设计与样本
- 纳入119例已检测房水和/或玻璃体IL-10及IL-6的患者,其中16例最终诊断为玻璃体视网膜淋巴瘤(第1组),103例最终诊断为葡萄膜炎(第2组)。
- 按IL-10、IL-6水平及人口学数据比较两组。
主要发现
- 第1组玻璃体IL-10均值为5,636 pg/mL,第2组为6.7 pg/mL;第1组房水IL-10均值为190 pg/mL,第2组为8.6 pg/mL。
- 第1组玻璃体IL-10/IL-6比值均值为29.02,房水为10.9;第2组两种体液比值均为0.1。
- 上述VRL与葡萄膜炎患者间的数值差异有统计学意义(P < 0.001)。
关键数值与推荐
- 玻璃体IL-10阈值65 pg/mL对应灵敏度93%、特异度100%。
- 房水IL-10阈值30 pg/mL对应灵敏度78%、特异度97%。
- 玻璃体IL-10/IL-6比值高于1对应灵敏度93%、特异度100%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To determine a threshold for interleukin (IL)-10 and IL-10/IL-6 ratio in the aqueous humor (AH) and the vitreous for the screening of vitreoretinal lymphoma (VRL). METHODS: One hundred nineteen patients for whom IL-10 and IL-6 in the AH and/or vitreous had been measured were included: 16 patients with a final diagnosis of VRL and 103 patients with final diagnosis of uveitis. Groups were compared according to IL-10 and IL-6 levels and demographic data. RESULTS: In patients with VRL (Group 1), mean IL-10 values were 5,636 pg/mL, and in patients with uveitis (Group 2), 6.7 pg/mL in the vitreous and 190 pg/mL in Group 1 and 8.6 pg/mL in the AH. In Group 1, the mean IL-10/IL-6 ratio was 29.02 in the vitreous and 10.9 in the AH; in Group 2, ratio was 0.1 in both humors. These values were significantly different between patients with VRL and with uveitis (P < 0.001). A cutoff of 65 pg/mL and 30 pg/mL IL-10 in the vitreous and AH, respectively, was associated with sensitivity of 93% and 78%, respectively, and specificity of 100% and 97%, respectively. A ratio higher than 1 in the vitreous had sensitivity of 93% and specificity of 100%. CONCLUSION: Vitreoretinal lymphoma diagnosis is difficult, and tools like interleukin measurements in AH and vitreous can make it easier. The use of a cutoff for IL-10 and IL-10/IL-6 ratio could allow for an earlier diagnosis that may improve prognosis.
引用
- Pochat-Cotilloux C, Bienvenu J, Nguyen AM, et al. USE OF A THRESHOLD OF INTERLEUKIN-10 AND IL-10/IL-6 RATIO IN OCULAR SAMPLES FOR THE SCREENING OF VITREORETINAL LYMPHOMA. Retina. 2018. PMID: 29135797. doi:10.1097/IAE.0000000000001922
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。