文献速递小儿眼科与斜弱视

翻转E字母在弱视筛查中是否过时?来自3-4岁儿童人群样本的常模证据

Should tumbling E go out of date in amblyopia screening? Evidence from a population-based sample normative in children aged 3-4 years.
PubMed 文献 · Br J Ophthalmol · 2017-10-07

该横断面研究纳入1756名3-4岁儿童,评估拥挤翻转E字母视力表的可行性与常模。总体可测率为95%(3岁92%、4岁98%);健康儿童首日平均视力0.14 logMAR(95%CI 0.14-0.15),两日最佳视力0.13 logMAR(95%CI 0.13-0.14)。作者认为这是欧洲白人儿童单眼拥挤翻转E字母的首个常模,也是比较3岁与4岁可测性的最大研究。

要点

  • 3岁儿童可测率92%,4岁98%,总体95%。
  • 首日平均视力0.14 logMAR(95%CI 0.14-0.15),两日最佳0.13 logMAR(95%CI 0.13-0.14)。
  • 总体假阳性转诊率1.3%,≥2 logMAR行屈光参差相关假阳性率0.17%。

核心结论

  • 这是欧洲白人儿童健康眼使用单眼拥挤翻转E字母的首个常模,也是比较3岁与4岁可测性的最大研究。
  • 可测率高于文献中其他视标,尤其在3岁儿童中高出5%-11%。

研究设计与样本

  • 横断面研究,邀请1756名儿童参加全面无创眼科检查,评估未矫正单眼拥挤翻转E字母视力。
  • 分析全人群可测率及健康儿童在不同年龄亚组、性别、学校类型和检查顺序下的视力。

主要发现

  • 总体可测率95%,3岁和4岁儿童分别为92%和98%。
  • 首日评估平均视力0.14 logMAR(95%CI 0.14-0.15)(小数视力0.72,95%CI 0.71-0.73),两日最佳视力0.13 logMAR(95%CI 0.13-0.14)(小数视力0.74,95%CI 0.73-0.74)。
  • 年龄分析显示首日视力组间差异有统计学意义(F(3,1146)=10.0;p<0.001;η2=0.026),最佳视力组间差异也有统计学意义(F(3,1155)=8.8;p<0.001;η2=0.022)。
  • 本常模与既往报道的HOTV-弱视治疗研究(HOTV-ATS)高度相关(首日视力r=0.97;最佳视力r=0.99),文献所述HOTV-ATS存在0.8至0.7行的持续高估。
  • 总体假阳性转诊率1.3%,≥2 logMAR行屈光参差相关假阳性率0.17%;眼间视力差≥1行logMAR与年龄无关(p=0.195)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: To determine a normative of tumbling E optotype and its feasibility for visual acuity (VA) assessment in children aged 3-4 years. METHODS: A cross-sectional study of 1756 children who were invited to participate in a comprehensive non-invasive eye exam. Uncorrected monocular VA with crowded tumbling E with a comprehensive ophthalmological examination were assessed. Testability rates of the whole population and VA of the healthy children for different age subgroups, gender, school type and the order of testing in which the ophthalmological examination was performed were evaluated. RESULTS: The overall testability rate was 95% (92% and 98% for children aged 3 and 4 years, respectively). The mean VA of the first-day assessment (first-VA) and best-VA over 2 days' assessments was 0.14 logMAR (95% CI 0.14 to 0.15) (decimal=0.72, 95% CI 0.71 to 0.73) and 0.13 logMAR (95% CI 0.13 to 0.14) (decimal=0.74, 95% CI 0.73 to 0.74). Analysis with age showed differences between groups in first-VA (F(3,1146)=10.0; p<0.001; η2=0.026) and best-VA (F(3,1155)=8.8; p<0.001; η2=0.022). Our normative was very highly correlated with previous reported HOTV-Amblyopia-Treatment-Study (HOTV-ATS) (first-VA, r=0.97; best-VA, r=0.99), with 0.8 to 0.7 lines consistent overestimation for HOTV-ATS as described in literature. Overall false-positive referral was 1.3%, being specially low regarding anisometropias of ≥2 logMAR lines (0.17%). Interocular difference ≥1 line VA logMAR was not associated with age (p=0.195). CONCLUSIONS: This is the first normative for European Caucasian children with single crowded tumbling E in healthy eyes and the largest study comparing 3 and 4 years old testability. Testability rates are higher than found in literature with other optotypes, especially in children aged 3 years, where we found 5%-11% better testability rates.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Guimaraes S, Fernandes T, Costa P, et al. Should tumbling E go out of date in amblyopia screening? Evidence from a population-based sample normative in children aged 3-4 years. Br J Ophthalmol. 2017. PMID: 28988161. doi:10.1136/bjophthalmol-2017-310691

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。