文献速递青光眼神经眼科

Bruch膜开口基于的视网膜神经节细胞层神经纤维层测量在同一天内的重复性

Intraday Repeatability of Bruch's Membrane Opening-Based Neuroretinal Rim Measurements.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2017-01-01

这项非干预性前瞻性队列研究纳入51例青光眼或高眼压患者,在同一天间隔5小时进行两次标准化SD-OCT视盘扫描和眼压测量,评估BMO-MRW、BMO-MRA和RNFL厚度的日内重复性。结果显示BMO-MRW的日内重复性高,与RNFL厚度相当,其变异性似乎不受眼压日内波动驱动,而BMO-MRA的个体内变异性较高。

要点

  • BMO-MRW的日内平均差异为2.95μm或1.76%,ICC大于0.994,重复性高。
  • RNFL厚度的日内平均差异为1.18μm或1.89%,与BMO-MRW的重复性相当。
  • BMO-MRA的日内平均差异为0.02mm2或2.68%,个体内变异性较高。

核心结论

  • SD-OCT评估BMO-MRW显示出高日内重复性,与RNFL厚度参数相当。
  • 变异性似乎并非由典型的日内眼压中度波动驱动。
  • 二维参数BMO-MRA具有相当高的个体内变异性。

研究设计与样本

  • 非干预性前瞻性队列研究,连续纳入51例青光眼或高眼压患者。
  • 在同一天两个不同时间点(间隔5小时)进行标准化SD-OCT视盘扫描和眼压评估。
  • 使用随机效应模型、组内相关系数(ICC)和Bland-Altman图分析BMO-MRW、BMO-MRA和RNFL厚度测量的重复性。

主要发现

  • 平均BMO面积为1.86±0.30 mm2。
  • 基线时平均BMO-MRW为206.46±0.86 μm,平均BMO-MRA为0.89±0.34 mm2,平均RNFL厚度为71.61±0.20 μm。
  • 个体内测量平均差异:BMO-MRW为2.95 μm或1.76%,BMO-MRA为0.02 mm2或2.68%,RNFL厚度为1.18 μm或1.89%。
  • 时间点比较:RNFL厚度η2=0.001(P=0.757),BMO-MRA η2=0.043(P=0.01),BMO-MRW η2=0.07(P=0.06)。
  • ICC均大于0.994。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess possible intraday variability in Bruch's membrane opening-based (BMO) assessment of neuroretinal rim by spectral-domain optical coherence tomography (SD-OCT) of the optic nerve head (ONH) as well as to evaluate its independence from intraindividual IOP changes. METHODS: In this noninterventional, prospective cohort study, 51 consecutively enrolled patients with glaucoma or ocular hypertension underwent standardized SD-OCT of the ONH and IOP assessment at two different time points with a time gap of 5 hours on the same day. Random effects models, intraclass correlation coefficients (ICC) and Bland-Altman plots were used to analyze repeatability of BMO minimum rim width (BMO-MRW) and area (BMO-MRA) and peripapillary retinal nerve fiber layer (RNFL) thickness measurements. RESULTS: Mean BMO area was 1.86 ± 0.30 mm2. At baseline, mean BMO-MRW was 206.46 ± 0.86 μm, mean BMO-MRA was 0.89 ± 0.34 mm2, and mean RNFL thickness was 71.61 ± 0.20 μm. Within intraindividual measurements, mean difference was 2.95 μm or 1.76% for BMO-MRW, 0.02 mm2 or 2.68% for BMO-MRA, and 1.18 μm or 1.89% for RNFL thickness. Comparing time points, η2 was 0.001 (P = 0.757) for RNFL thickness, 0.043 (P = 0.01) for BMO-MRA, and 0.07 (P = 0.06) for BMO-MRW. Intraclass correlation coefficients were greater than 0.994, respectively. Variability of morphometric parameters did not correlate to intraindividual IOP fluctuations. CONCLUSIONS: Assessment of BMO-MRW by SD-OCT shows high intraday repeatability, which is comparable to the parameter RNFL thickness. Variability seems not to be driven by typical moderate intraday fluctuations of IOP. The two-dimensional parameter BMO-MRA incorporates a fairly higher intraindividual variability.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Enders P, Bremen A, Schaub F, et al. Intraday Repeatability of Bruch's Membrane Opening-Based Neuroretinal Rim Measurements. Invest Ophthalmol Vis Sci. 2017. PMID: 29049719. doi:10.1167/iovs.17-22812

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。