急性眼压升高对大鼠视网膜闪烁刺激功能与血流反应的影响
研究评估急性眼压升高至约45毫米汞柱对大鼠视网膜闪烁刺激诱导的功能与血流反应的影响。11只Brown Norway大鼠在正常眼压、眼压升高期间及移除血管环后10分钟同步测量总视网膜血流量与视网膜电图。急性眼压升高抑制了闪烁刺激诱导的总视网膜血流量变化和视网膜电图二次谐波成分,移除血管环后约10分钟内恢复。
要点
- 急性眼压升高至约45毫米汞柱时,总视网膜血流量从5.6±1.9微升/分钟降至3.8±1.2微升/分钟(P<0.01)。
- 眼压升高期间闪烁刺激诱导的总视网膜血流量变化从6.0±3.3%降至0.1±0.3%(P<0.01)。
- 眼压升高期间视网膜电图二次谐波成分降至基线的55%(P<0.01),移除血管环后仍显著低于基线(P<0.01)。
核心结论
- 急性眼压升高至45毫米汞柱导致大鼠视网膜对闪烁刺激的功能反应和总视网膜血流量反应受到抑制。
研究设计与样本
- 研究纳入15只Brown Norway大鼠,在氯胺酮/赛拉嗪麻醉前进行暗适应。
- 用血管环将一只眼眼压急性升高至约45毫米汞柱。
- 11只大鼠在眼压升高前、眼压升高期间及移除血管环后10分钟接受白光闪烁刺激(10赫兹,持续2秒,0.80 log scotopic cd·s/m2),用光学相干断层扫描联合视网膜电图系统同步测量总视网膜血流量和视网膜功能变化。
- 其余4只大鼠在麻醉注射后10至90分钟频繁测量全身血压。
主要发现
- 全身血压在整个测量期间维持在99±4毫米汞柱(n=4)。
- 正常眼压下总视网膜血流量为5.6±1.9微升/分钟,视神经乳头附近平均视网膜血管尺寸为44.1±4.5微米。
- 眼压升高期间总视网膜血流量显著降低至3.8±1.2微升/分钟(P<0.01),血管尺寸显著缩小至35.1±2.6微米(P<0.01),两者在移除血管环后约10分钟内恢复至基线。
- 正常眼压下闪烁刺激诱导的总视网膜血流量变化为6.0±3.3%,眼压升高期间显著降至0.1±0.3%(P<0.01),移除血管环后10分钟内恢复至5.9±1.7%。
- 眼压升高期间视网膜电图二次谐波成分幅度降至基线值的55%(P<0.01),且仍显著低于基线(P<0.01)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the effect of acutely elevated intraocular pressure (IOP) on the functional and blood flow responses of the rat retina to flicker stimulation. METHODS: Brown Norway (n = 15) rats were dark-adapted before ketamine/xylazine anesthesia. IOP was raised acutely in one eye to ∼45 mm Hg with a vascular loop. In 11 rats, white light flicker stimulus (10 Hz, 2 seconds duration, 0.80 log scotopic cd·s/m2) was applied before and during IOP elevation, and 10 minutes after loop removal. Changes in the total retinal blood flow (TRBF) and retinal function induced by the visual stimulus were measured simultaneously with a combined optical coherence tomography (OCT) + electroretinography (ERG) system. Systemic blood pressure was measured in the remaining four rats frequently from 10 to 90 minutes post anesthesia injection. RESULTS: The systemic blood pressure remained at 99 ± 4 mm Hg throughout the measurements (n = 4). Under normal IOP, the TRBF was 5.6 ± 1.9 μL/min, and the average retinal blood vessel size (BVS) in the vicinity of the optic nerve head (ONH) was 44.1 ± 4.5 μm. During IOP elevation, the TRBF was significantly lower (3.8 ± 1.2 μL/min, P < 0.01) and the BVS was significantly smaller (35.1 ± 2.6 μm, P < 0.01). Both TRBF and BVS returned to baseline within ∼10 minutes from removal of the vascular loop. The flicker-induced TRBF change measured under normal IOP (6.0 ± 3.3%) was reduced significantly to 0.1 ± 0.3% (P < 0.01) during IOP elevation, and recovered to 5.9 ± 1.7% within 10 minutes after loop removal. During IOP elevation, the magnitude of the ERG second harmonic component (SHC) decreased to 55% of its baseline value (P < 0.01) and remained significantly smaller than baseline (P < 0.01). CONCLUSIONS: Acute IOP elevation to 45 mm Hg caused suppression of the retinal functional and TRBF response to flicker stimulation.
引用
- Tan B, MacLellan B, Mason E, et al. The Effect of Acutely Elevated Intraocular Pressure on the Functional and Blood Flow Responses of the Rat Retina to Flicker Stimulation. Invest Ophthalmol Vis Sci. 2017. PMID: 29075764. doi:10.1167/iovs.17-22412
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。