文献速递青光眼神经眼科

利用「大数据」在虚拟眼科诊所中监测测量指标的示例

Example of monitoring measurements in a virtual eye clinic using 'big data'.
PubMed 文献 · Br J Ophthalmol · 2017-10-26

该研究比较了在青光眼监测服务(GMS)就诊的250例患者与标准青光眼诊疗服务患者「大数据」数据库中患者的视野检查结果,发现GMS患者平均MD在两次连续就诊间为+1.6dB至-18.9dB,4.8%(95%CI 2.5%至8.2%)的GMS患者超出参考数据库90%预期值,1.9%(95%CI 0.4%至5.4%)的GMS患者视野变化超出预期90%限值,结论为GMS患者在视野检查上具有等效结局。

要点

  • GMS患者平均MD在两次连续就诊间范围为+1.6dB至-18.9dB。
  • 4.8%(95%CI 2.5%至8.2%)的GMS患者评分超出参考数据库90%预期值。
  • 1.9%(95%CI 0.4%至5.4%)的GMS患者视野变化超出预期90%限值。

核心结论

  • 利用标准青光眼诊疗服务中收集的「大数据」,本研究发现GMS患者在视野检查上具有等效结局。
  • 研究结果为在医院眼科服务中实施虚拟医疗服务提供了支持。

研究设计与样本

  • 研究比较了250例GMS患者与标准青光眼诊疗服务患者「大数据」数据库(参考数据库)的视野检查平均MD测量值。
  • 同时比较了GMS患者与参考数据库患者之间视野进展速度。

主要发现

  • GMS患者平均MD在两次连续就诊间范围为+1.6dB至-18.9dB。
  • 第一次分析中,12例(4.8%;95%CI 2.5%至8.2%)GMS患者评分超出基于参考数据库的90%预期值。
  • 第二次分析中,1.9%(95%CI 0.4%至5.4%)的GMS患者视野变化超出预期90%限值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To assess the equivalence of measurement outcomes between patients attending a standard glaucoma care service, where patients see an ophthalmologist in a face-to-face setting, and a glaucoma monitoring service (GMS). METHODS: The average mean deviation (MD) measurement on the visual field (VF) test for 250 patients attending a GMS were compared with a 'big data' repository of patients attending a standard glaucoma care service (reference database). In addition, the speed of VF progression between GMS patients and reference database patients was compared. Reference database patients were used to create expected outcomes that GMS patients could be compared with. For GMS patients falling outside of the expected limits, further analysis was carried out on the clinical management decisions for these patients. RESULTS: The average MD of patients in the GMS ranged from +1.6dB to -18.9dB between two consecutive appointments at the clinic. In the first analysis, 12 (4.8%; 95% CI 2.5% to 8.2%) GMS patients scored outside the 90% expected values based on the reference database. In the second analysis, 1.9% (95% CI 0.4% to 5.4%) GMS patients had VF changes outside of the expected 90% limits. CONCLUSIONS: Using 'big data' collected in the standard glaucoma care service, we found that patients attending a GMS have equivalent outcomes on the VF test. Our findings provide support for the implementation of virtual healthcare delivery in the hospital eye service.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Jones L, Bryan SR, Miranda MA, et al. Example of monitoring measurements in a virtual eye clinic using 'big data'. Br J Ophthalmol. 2017. PMID: 29074497. doi:10.1136/bjophthalmol-2017-310440

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。