萎缩型年龄相关性黄斑变性眼中的绿色发射荧光团:彩色眼底自发荧光初步研究
前瞻性观察性横断面病例系列纳入25眼(18例)晚期年龄相关性黄斑变性(AMD)伴临床识别黄斑萎缩(MA)者,用450 nm激发彩色眼底自发荧光(FAF)成像检测MA区绿色发射荧光成分(GEFC)。14眼(56.0%)MA区存在GEFC,11眼(44.0%)不存在,GEFC与对应SD-OCT上Bruch膜上高反射物质相关。
要点
- 25眼中14眼(56.0%)MA区存在GEFC,11眼(44.0%)不存在。
- MA区GEFC的存在与分布和对应SD-OCT上Bruch膜上高反射物质相关。
- 短波荧光团存在于MA区,似乎对应残留碎屑或玻璃膜疣样物质。
核心结论
- 短波荧光团存在于MA区,似乎对应残留碎屑或玻璃膜疣样物质。
- 彩色FAF成像显示的短波荧光团可能值得进一步研究。
研究设计与样本
- 前瞻性、观察性、横断面病例系列,纳入25眼(18例)晚期AMD伴临床识别MA者。
- 使用450 nm激发波长、具备彩色FAF成像能力的共聚焦发光二极管蓝光FAF设备(EIDON,CenterVue,帕多瓦,意大利)成像,并从总FAF图像中减去红色成分以突出绿色成分。
- 主要结局指标为MA区内绿色发射荧光成分(GEFC)的存在。
- 经黄斑区获取容积谱域光学相干断层扫描(SD-OCT),并与FAF图像识别的MA病灶(包括GEFC增高区域)进行关联。
主要发现
- 25眼中14眼(56.0%)MA区存在GEFC,11眼(44.0%)MA区不存在GEFC。
- MA区GEFC的存在与分布和对应SD-OCT扫描上Bruch膜上高反射物质的存在相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND/AIMS: To investigate the presence of short-wave fluorophores within regions of age-related macular degeneration (AMD)-associated macular atrophy (MA) area. METHODS: This is a prospective, observational, cross-sectional case series. 25 eyes (18 patients) with late AMD and clinically identified MA were enrolled. Eyes were imaged using a confocal light-emitting diode blue-light fundus autofluorescence (FAF) device (EIDON, CenterVue, Padua, Italy) with 450 nm excitation wavelength and the capability for 'colour' FAF imaging, including both the individual red and green components of the emission spectrum. To produce images with a high contrast for isolating the green component, the red component was subtracted from the total FAF image. The main outcome measure was the presence of green emission fluorescence component (GEFC) within the MA area. Volume spectral domain optical coherence tomography (SD-OCT) scans were obtained through the macula and the OCT was correlated with the MA lesions identified on the FAF images, including regions of increased GEFC. RESULTS: Of the investigated eyes, 11 out of 25 (44.0 %) showed the absence of GEFC in the MA area, whereas 14 eyes (56.0%) were characterised by GEFC within the MA area. The presence and distribution of GEFC in the MA area correlated with the presence of hyper-reflective material over Bruch's membrane on the corresponding SD-OCT scans. CONCLUSION: Short-wave fluorophores, which contribute to the GEFC, are present in the MA area and appear to correspond to residual debris or drusenoid material. Short-wavelength fluorophores revealed by colour FAF imaging may warrant further study.
引用
- Borrelli E, Lei J, Balasubramanian S, et al. Green emission fluorophores in eyes with atrophic age-related macular degeneration: a colour fundus autofluorescence pilot study. Br J Ophthalmol. 2017. PMID: 28972030. doi:10.1136/bjophthalmol-2017-310881
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。