新生血管性年龄相关性黄斑变性(AMD)病灶大小测量的光学相干断层扫描血管成像可重复性
前瞻性非干预研究纳入48眼(46例新生血管性AMD患者),由同一检查者连续行两次OCTA检查,两名设盲阅片者用内置半自动软件测量脉络膜新生血管面积。两次测量平均面积分别为0.72±0.7 mm²和0.75±0.76 mm²,差值为0.03 mm²;两种测量功能的用户内一致性均为0.98,用户间一致性为0.98。作者认为OCTA可为AMD新生血管大小评估提供可重复的影像。
要点
- 48眼连续两次OCTA检查,脉络膜新生血管平均面积第一次0.72±0.7 mm²、第二次0.75±0.76 mm²,差值0.03 mm²。
- 用户内一致性「血管面积」和「选择面积」均为0.98(CI 0.98至0.99)。
- 用户间一致性「选择面积」和「血管面积」均为0.98(CI 0.97至0.99)。
核心结论
- 作者认为,OCTA在AMD背景下评估新生血管大小可提供可重复的影像。
研究设计与样本
- 前瞻性非干预研究,连续纳入表现为新生血管性年龄相关性黄斑变性(AMD)的患者。
- 同一名受过培训的检查者使用AngioVue(Optovue,Fremont,California,USA)行两次连续OCTA检查。
- 两名设盲阅片者在脉络膜毛细血管自动分割上使用仪器内置半自动测量软件测量新生血管病灶面积。
- 使用两种测量功能:第一种为用血流描绘工具(选择区域)手工勾画的总病灶面积,第二种为病灶内仅高血流血管的总面积(血管面积)。
- 共纳入46例患者的48眼,平均年龄77.4岁(±8.2 SD,范围62至95岁),男8例、女38例。
主要发现
- 脉络膜新生血管平均面积第一次测量为0.72±0.7 mm²,第二次测量为0.75±0.76 mm²,第一次与第二次测量差值为0.03 mm²。
- 用户内一致性「血管面积」和「选择面积」均为0.98(CI 0.98至0.99)。
- 用户间一致性「选择面积」和「血管面积」均为0.98(CI 0.97至0.99)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the reproducibility and interuser agreement of measurements of choroidal neovascularisation in optical coherence tomography angiography (OCTA). DESIGN: Prospective non-interventional study. METHODS: Consecutive patients, presenting with neovascular age-related macular degeneration (AMD), underwent two sequential OCTA examinations (AngioVue, Optovue, Fremont, California, USA), performed by the same trained examiner. Neovascular lesion area was then measured on both examinations in the choriocapillaris automatic segmentation by two masked readers, using the semiautomated measuring software embedded in the instrument. Two measuring features were used: the first corresponding to the total manually contoured lesion area with the flow draw tool (select area) and the second to the total area of solely vessels with high flow within the lesion (vessel area). These measurements were then compared in order to assess both the reproducibility of OCTA examination and the interuser agreement with the embedded software. RESULTS: Forty-eight eyes of 46 patients (77.4 mean age,+/-8.2 SD, range from 62 to 95 years old, eight men, 38 women) were included in our study. Mean choroidal neovascularisation area was of 0.72+/-0.7 mm2 for the first measurement and 0.75+/-0.76 mm2 for the second measurement; difference between the first and the second measurement was 0.03 mm2. Intrauser agreement was of 0.98 (CI 0.98 to 0.99) for both 'vessel area' and 'select area' features. Interuser agreement was of 0.98 (CI 0.97 to 0.99) for 'select area' and 'vessel area' features. CONCLUSION: Our data suggest that OCTA provide reproducible imaging for evaluation of the neovascular size in the setting of AMD.
引用
- Amoroso F, Miere A, Semoun O, et al. Optical coherence tomography angiography reproducibility of lesion size measurements in neovascular age-related macular degeneration (AMD). Br J Ophthalmol. 2017. PMID: 28855197. doi:10.1136/bjophthalmol-2017-310569
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。