玻璃体后脱离与玻璃体后界膜
本研究对36只人供体眼球行组织学与免疫组化检查,发现玻璃体后脱离后包裹玻璃体后表面的玻璃体后界膜为IV型胶原阳性的真实基底膜,仅在玻璃体后脱离后可见,提示其在玻璃体附着状态下属于内界膜的一部分。
要点
- 玻璃体后脱离后包裹玻璃体后表面的玻璃体后界膜为IV型胶原阳性的真实基底膜。
- 该膜性结构仅在玻璃体后脱离后可见,提示其在玻璃体附着时属于内界膜的一部分。
- 视网膜表面残留的完整内界膜同样呈IV型胶原阳性。
核心结论
- 免疫组化证据表明玻璃体后界膜是包裹玻璃体后表面的真实基底膜。
- 该膜性结构仅在玻璃体后脱离后可见,提示其在玻璃体附着状态下构成内界膜的一部分。
研究设计与样本
- 临床组织学相关性研究,纳入36只人供体眼球。
- 对确认有玻璃体后脱离的玻璃体行相差显微镜和共聚焦显微镜检查,并免疫组化染色IV型胶原基底膜标志物及纤连蛋白、层粘连蛋白、opticin等细胞外蛋白。
- 对视网膜后部同样染色以评估内界膜,并与裂隙灯生物显微镜下观察的玻璃体后界膜临床外观及既往发表研究进行关联比较。
主要发现
- 相差显微镜一致识别出包裹玻璃体后表面的皱褶、清晰的玻璃样膜片,与玻璃体后脱离患者裂隙灯下观察到的玻璃体后界膜密切对应。
- 免疫荧光共聚焦显微图像显示相差显微镜所见的包裹性膜性结构IV型胶原染色阳性。
- 视网膜表面残留的完整内界膜免疫荧光亦显示IV型胶原染色阳性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Despite posterior vitreous detachment being a common ocular event affecting most individuals in an aging population, there is little consensus regarding its precise anatomic definition. We investigated the morphologic appearance and molecular composition of the posterior hyaloid membrane to determine whether the structure clinically observed enveloping the posterior vitreous surface after posterior vitreous detachment is a true basement membrane and to postulate its origin. Understanding the relationship between the vitreous (in both its attached and detached state) and the internal limiting membrane of the retina is essential to understanding the cause of rhegmatogenous retinal detachment and vitreoretinal interface disorders, as well as potential future prophylactic and treatment strategies. DESIGN: Clinicohistologic correlation study. PARTICIPANTS: Thirty-six human donor globes. METHODS: Vitreous bodies identified to have posterior vitreous detachment were examined with phase-contrast microscopy and confocal microscopy after immunohistochemically staining for collagen IV basement membrane markers, in addition to extracellular proteins that characterize the vitreoretinal junction (fibronectin, laminin) and vitreous gel (opticin) markers. The posterior retina similarly was stained to evaluate the internal limiting membrane. Findings were correlated to the clinical appearance of the posterior hyaloid membrane observed during slit-lamp biomicroscopy after posterior vitreous detachment and compared with previously published studies. MAIN OUTCOME MEASURES: Morphologic appearance and molecular composition of the posterior hyaloid membrane. RESULTS: Phase-contrast microscopy consistently identified a creased and distinct glassy membranous sheet enveloping the posterior vitreous surface, correlating closely with the posterior hyaloid membrane observed during slit-lamp biomicroscopy in patients with posterior vitreous detachment. Immunofluorescent confocal micrographs demonstrated the enveloping membranous structure identified on phase-contrast microscopy to show positive stain results for type IV collagen. Immunofluorescence of the residual intact internal limiting membrane on the retinal surface also showed positive stain results for type IV collagen. CONCLUSIONS: The results of this study provide immunohistochemical evidence that the posterior hyaloid membrane is a true basement membrane enveloping the posterior hyaloid surface. Because this membranous structure is observed only after posterior vitreous detachment, the results of this study indicate that it forms part of the internal limiting membrane when the vitreous is in its attached state.
引用
- Fincham GS, James S, Spickett C, et al. Posterior Vitreous Detachment and the Posterior Hyaloid Membrane. Ophthalmology. 2017. PMID: 28867131. doi:10.1016/j.ophtha.2017.08.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。