骨性人工角膜眼视网膜脱离手术的结果
该回顾性观察研究纳入18只骨性人工角膜植入后发生视网膜脱离并接受平坦部玻璃体切除术的眼,随访至少1年;解剖成功率为56%,功能成功率为17%,术后最常见并发症为人工角膜后膜(33%)。作者认为尽管预后保守且并发症严重,玻璃体切除术仍是治疗此类视网膜脱离的有效方法,解剖结果良好但视力较差。
要点
- 骨性人工角膜眼视网膜脱离行玻璃体切除术后解剖成功率为56%。
- 功能成功率(术后视力≥20/400)为17%。
- 术后最常见并发症为人工角膜后膜(33%)。
核心结论
- 尽管预后保守且并发症严重,玻璃体切除术是治疗骨性人工角膜患者视网膜脱离的有效方法,解剖结果良好但视力较差。
研究设计与样本
- 观察性回顾性研究,纳入18只骨性人工角膜植入后发生视网膜脱离并接受平坦部玻璃体切除术的眼,随访至少1年。
- 采用描述性研究及Kaplan-Meier生存分析评估解剖成功与功能成功。
主要发现
- 总体解剖成功率为56%,术后6个月和12个月解剖生存率分别为67%和53%,12个月的值维持至术后24个月。
- 总体功能成功率为17%,术后6个月、12个月和24个月功能生存率分别为83%、39%和14%。
- 视网膜手术后最常见并发症为人工角膜后膜(33%)。
关键数值与推荐
- 解剖成功定义为玻璃体视网膜手术结束时视网膜复位且随访期间无再脱离。
- 功能成功定义为术后视力≥20/400。
临床怎么用
- 原文结论认为玻璃体切除术是治疗骨性人工角膜患者视网膜脱离的有效方法,解剖结果良好但视力较差。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the anatomical and functional results of pars plana vitrectomy in eyes with osteo-keratoprosthesis, who have suffered retinal detachment. METHODS: An observational, retrospective study of 18 eyes which underwent pars plana vitrectomy for retinal detachment after an implantation of an osteo-keratoprosthesis, with a minimum of 1-year follow-up. A descriptive study and a Kaplan-Meier survival analysis for anatomical and functional success were performed. Anatomical success was defined as an attached retina at the end of vitreoretinal surgery with no redetachment during the follow-up. Functional success was defined as a postoperative visual acuity of more than or equal to 20/400. RESULTS: The overall rate of anatomical success was 56%, and the anatomical survival rates were 67% and 53% at 6 months and 12 months, respectively, maintaining this last value at 24 months after pars plana vitrectomy. The overall rate of functional success was 17%, and the functional survival rates were 83%, 39%, and 14% at 6 months, 12 months, and 24 months after pars plana vitrectomy, respectively. The most frequent complication after retinal surgery was retroprosthetic membrane (33%). CONCLUSION: Despite the reserved prognosis and the severe complications, vitrectomy represents a valid method for treating retinal detachment in patients with osteo-keratoprosthesis, with good anatomical results but poor visual acuity.
引用
- Vilaplana F, Nadal J, Temprano J, et al. RESULTS OF RETINAL DETACHMENT SURGERY IN EYES WITH OSTEO-KERATOPROSTHESIS. Retina. 2018. PMID: 28961672. doi:10.1097/IAE.0000000000001865
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。